HomeMy WebLinkAboutP100WC-1A
L-1A
L-1A
L-1A
L-1A
L-1A
WC-1AWC-1A
WC-1UR-1A
MS-1
FD-1FD-1
FD-1
FD-2
2" Pump discharge from
overflow pump. Slope to
drain into pit. Extend to
5'-0" beyond bldg. line.
See Civil plans for cont.
2" Pump discharge
to spill into 4" dia.
standpipe.
CO-1
2" Pump discharge from
overflow pump. Slope to
drain into pit. Extend to
5'-0" beyond bldg. line.
See Civil plans for cont.
CO-2
IE=756.50
SP-1
Hold 4"W
piping as
tight to pit
wall as
practical.
FFE=759.50
FFE=758.83 4"W
2"W4"W2"W
2"W
4"W
3"W
4"W
Turn 114"Pump
discharge down
into 4"W piping.
WH-1
RPZ-1
RPZ-2
34"Tempered water to
serve exterior shower.
Slope to drain into pit.
Extend to 5'-0" beyond
bldg. line. See Civil
plans for continuation.
34"CW to serve exterior
drinking fountain. Slope
to drain into pit. Extend
to 5'-0" beyond bldg. line.
See Civil plans for cont.
2"Domestic water
service. Extend to
5'-0" beyond bldg.
line. See Civil plans
for continuation.
WHA-C
Provide HB-1 on HW &
CW lines at +12" A.F.F.
Provide HB-1 on HW &
CW lines at +12" A.F.F.
Provide HB-1 on HW &
CW lines at +12" A.F.F.
MV-2
Provide HB-1 at
bottom of supply pipe
for winterization.
1"CW to serve holding
tank. Extend to 5'-0"
beyond bldg. line. See
Civil plans for cont.
IE= Min. -5'-0" below grade.
(typ for all exterior water lines)
112"CW
12"HW
112"CW
34"HW
112"CW
34"HW
2"CW
34"HW
2"CW
34"HW
2"CW
34"HW
34"CW
34"HW
A.All fittings, piping, fixtures, materials, etc. to meet the
current Safe Drinking Water Act with all of its
amendments and the Reduction of Lead in Drinking
water Act.
B.All work shall comply with all national, state, local codes
and ordinances pertaining to the work in this project.
C.All plumbing fixtures shall be supplied with individual
water supply stops and code approved traps. Exposed
piping shall be chrome plated.
D.All plumbing fixtures shall be installed with approved
backflow prevention devices.
E.No piping shall pass directly over electrical power
distribution cabinets, panelboards, etc. Contractor to
coordinate panel locations prior to piping installation.
F.All plumbing vents to be a minimum of 10'-0" from any air
intake. Coordinate locations with HVAC plans.
G.Single runouts to plumbing fixtures shall be the same
size as on the plumbing fixture schedule unless
otherwise noted.
H.All waste, water, and vent lines shown to be connected
to their associated fixture/equipment, unless noted
otherwise. All equipment and systems shown must be
complete and usable upon completion of project.
)GPGTCN0QVGU
Turn 114"Pump
discharge down
into 4"W piping.
4"dia.
standpipe
Hold piping as
tight to pit wall
as practical.WC-1AL-1A L-1A
L-1A
L-1A
L-1A
WC-1A
WC-1A
WC-1
UR-1A
MS-1
FD-1
FD-1
FD-1
FD-2
CO-1
CO-2
SP-1
4"W
4"W
3"W
4"W
2"V
2"V
4"VTR, minimum
10'-0" from any
outdoor air intake.
2"W
2"W
4"W
4"W
6"W
112"V
112"V
2"V
2"V
2"W
10 9abcd 8 7 6efgh109876 REVISIONS AND ISSUES5 4 3 2 1 PREPARED FOR:PROJECT NO.
SHEET NO.abcd5 4 3 2
CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATEBYeDATE:1
ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netfhgSection 1, Township 17 North, Range 3 East, Clay Township, Hamilton County, IndianaW200371CARMEL, IN 46033W20062003/05/2021LAWRENCE W. INLOW PARKPHASE II IMPROVEMENTSPROF
E
SSIONA L E N G NIEERSA M U E L L.HU
R
TINDIA N A
0
N
EP1 6
.o
01087
ATS FOET
R E TEGIS
D
ER
Exp. 7.31.2022
Genesis Design, Inc.GNIBMULP·LACITCELE·LACINAHCEM R2410 Executive Drive - Suite 100
Indianapolis, Indiana 46241