HomeMy WebLinkAboutP100WC-1A L-1A L-1A L-1A L-1A L-1A WC-1AWC-1A WC-1UR-1A MS-1 FD-1FD-1 FD-1 FD-2 2" Pump discharge from overflow pump. Slope to drain into pit. Extend to 5'-0" beyond bldg. line. See Civil plans for cont. 2" Pump discharge to spill into 4" dia. standpipe. CO-1 2" Pump discharge from overflow pump. Slope to drain into pit. Extend to 5'-0" beyond bldg. line. See Civil plans for cont. CO-2 IE=756.50 SP-1 Hold 4"W piping as tight to pit wall as practical. FFE=759.50 FFE=758.83 4"W 2"W4"W2"W 2"W 4"W 3"W 4"W Turn 114"Pump discharge down into 4"W piping. WH-1 RPZ-1 RPZ-2 34"Tempered water to serve exterior shower. Slope to drain into pit. Extend to 5'-0" beyond bldg. line. See Civil plans for continuation. 34"CW to serve exterior drinking fountain. Slope to drain into pit. Extend to 5'-0" beyond bldg. line. See Civil plans for cont. 2"Domestic water service. Extend to 5'-0" beyond bldg. line. See Civil plans for continuation. WHA-C Provide HB-1 on HW & CW lines at +12" A.F.F. Provide HB-1 on HW & CW lines at +12" A.F.F. Provide HB-1 on HW & CW lines at +12" A.F.F. MV-2 Provide HB-1 at bottom of supply pipe for winterization. 1"CW to serve holding tank. Extend to 5'-0" beyond bldg. line. See Civil plans for cont. IE= Min. -5'-0" below grade. (typ for all exterior water lines) 112"CW 12"HW 112"CW 34"HW 112"CW 34"HW 2"CW 34"HW 2"CW 34"HW 2"CW 34"HW 34"CW 34"HW A.All fittings, piping, fixtures, materials, etc. to meet the current Safe Drinking Water Act with all of its amendments and the Reduction of Lead in Drinking water Act. B.All work shall comply with all national, state, local codes and ordinances pertaining to the work in this project. C.All plumbing fixtures shall be supplied with individual water supply stops and code approved traps. Exposed piping shall be chrome plated. D.All plumbing fixtures shall be installed with approved backflow prevention devices. E.No piping shall pass directly over electrical power distribution cabinets, panelboards, etc. Contractor to coordinate panel locations prior to piping installation. F.All plumbing vents to be a minimum of 10'-0" from any air intake. Coordinate locations with HVAC plans. G.Single runouts to plumbing fixtures shall be the same size as on the plumbing fixture schedule unless otherwise noted. H.All waste, water, and vent lines shown to be connected to their associated fixture/equipment, unless noted otherwise. All equipment and systems shown must be complete and usable upon completion of project. )GPGTCN0QVGU Turn 114"Pump discharge down into 4"W piping. 4"dia. standpipe Hold piping as tight to pit wall as practical.WC-1AL-1A L-1A L-1A L-1A L-1A WC-1A WC-1A WC-1 UR-1A MS-1 FD-1 FD-1 FD-1 FD-2 CO-1 CO-2 SP-1 4"W 4"W 3"W 4"W 2"V 2"V 4"VTR, minimum 10'-0" from any outdoor air intake. 2"W 2"W 4"W 4"W 6"W 112"V 112"V 2"V 2"V 2"W 10 9abcd 8 7 6efgh109876 REVISIONS AND ISSUES5 4 3 2 1 PREPARED FOR:PROJECT NO. SHEET NO.abcd5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATEBYeDATE:1 ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netfhgSection 1, Township 17 North, Range 3 East, Clay Township, Hamilton County, IndianaW200371CARMEL, IN 46033W20062003/05/2021LAWRENCE W. INLOW PARKPHASE II IMPROVEMENTSPROF E SSIONA L E N G NIEERSA M U E L L.HU R TINDIA N A 0 N EP1 6 .o 01087 ATS FOET R E TEGIS D ER Exp. 7.31.2022 Genesis Design, Inc.GNIBMULP·LACITCELE·LACINAHCEM R2410 Executive Drive - Suite 100 Indianapolis, Indiana 46241 317.636.3941 YYY6'%Ä/'2EQO THEENGINEERINGC O L L A B OR A T I VEGJRSLHGJR