Loading...
HomeMy WebLinkAboutE010 - SITE PHOTOMETRIC PLANESL-Spectrum's services are for estimation purposes only, and are not warranties. Final design and illumination levels must be determined and specified by an electrical engineer. Field results may differ from computer predictions because of many uncontrollable factors and adverse test conditions such as: line voltage variations, lamp performance, product manufacturing tolerances, and jobsite conditions. THE FIXTURE TYPE(S) AND LAMPING(S) SPECIFIED ON THIS LAYOUT MUST BE USED IN ORDER TO MEET THE EXACT CRITERIA AND PERFORMANCE DATA SHOWN. PHOTOMETRIC PLAN DESIGNED BY ESL-SPECTRUM WWW.ESL-SPECTRUM.COM PHONE: 317.951.2300 PROJECT NUMBER: 20200277-JH PROJECT NAME: STATE BANK CARMEL BRANCH DATE: 12-7-2020 03/15/21 SITE LIGHTING - PLAN VIEW Scale: 1 inch= 12 Ft. TTV S AC AC EH EH TR S CV S1 MH: 7 S1 MH: 7MH: 7 S1 MH: 7 S1 MH: 7 S1 F2 MH: 0.5 F2 MH: 0.5 MH: 7 S1 S1 MH: 7 H-24' MH: 17 W1 MH: 0 F2 MH: 0.5 MH: 0.5 F2 F2 MH: 0.5 F2 MH: 0.5 F2 MH: 0.5 F2 MH: 0.5 MH: 13 R2 MH: 13 R2 MH: 13 R2 R2 MH: 13 MH: 13 R2 MH: 13 R2 V6 MH: 20 V6 MH: 20 V6 MH: 20 0.9 5.5 9.1 7.0 1.2 0.2 0.2 0.4 0.5 0.6 0.8 0.1 0.1 0.2 0.4 0.6 1.1 4.8 7.7 6.1 1.3 0.4 0.4 0.7 1.0 1.1 1.4 0.1 0.2 0.4 6.3 4.7 7.1 3.1 3.8 5.8 5.9 0.4 0.6 1.0 1.3 1.6 1.8 0.1 0.3 0.8 1.2 1.5 2.1 2.6 0.2 0.4 0.1 0.1 0.1 0.6 4.1 6.3 5.0 0.8 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 1.1 1.3 1.5 2.2 2.8 0.2 0.4 1.2 1.2 1.4 1.8 2.0 0.2 0.3 0.9 1.1 1.3 1.3 1.6 0.2 0.4 0.9 0.9 1.0 1.0 1.3 0.3 0.5 1.0 1.7 3.0 4.7 5.7 4.8 2.9 1.5 1.1 1.0 1.0 0.9 0.8 0.7 0.3 0.7 1.2 1.7 2.2 2.7 2.8 2.4 1.6 1.1 1.2 1.3 1.3 1.3 1.1 0.9 0.2 0.8 1.3 1.7 2.0 2.1 2.0 1.6 1.1 0.9 1.2 1.5 1.6 1.5 0.3 0.9 1.3 2.6 2.6 2.0 1.4 1.0 0.9 1.3 1.8 2.3 2.4 0.3 1.2 1.7 3.2 3.0 2.1 1.8 1.2 1.2 1.7 2.0 2.8 3.0 0.1 0.5 0.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.6 0.8 0.7 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 1.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 1.7 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.9 0.3 2.6 0.2 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.8 2.3 2.7 0.3 0.1 0.0 0.0 0.0 0.0 0.1 0.1 1.1 2.5 1.8 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.7 1.3 1.4 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.7 2.2 5.7 11.0 14.0 11.6 6.3 2.3 1.1 1.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.4 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.5 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.1 1.4 1.1 0.6 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 2.0 1.8 1.2 0.7 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.1 2.2 2.0 1.6 1.1 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.6 1.0 0.9 0.6 0.7 0.4 0.5 0.9 1.0 1.3 1.4 0.9 0.8 0.6 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 25.5 25.525.6 24.921.0 21.015.3 16.49.7 10.75.6 5.92.7 3.61.3 1.80.8 1.20.7 1.326.1 26.7 24.9 25.0 0.40.5 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.2 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 1.0 1.6 1.4 0.3 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.2 0.4 0.8 0.4 0.6 0.91.2 1.4 1.72.5 2.5 0.5 fc 1 fc 0.25 fc 0.1 fc 0.5 fc 1 fc 0.25 fc 0.1 fc 1 fc PHOTOMETRIC PLAN DESIGNED BY ESL-SPECTRUM WWW.ESL-SPECTRUM.COM PHONE: 317.951.2300 CALCULATIONS ARE MAINTAINED HORIZONTAL ILLUMINANCE FIGURES IN FOOT-CANDLES POINTS SHOWN ARE AT GRADE FIXTURE MOUNTING HEIGHTS ARE SPECIFIED NEXT TO FIXTURES AS "MH" ESL-Spectrum's services are for estimation purposes only, and are not warranties. Final design and illumination levels must be determined and specified by an electrical engineer. Field results may differ from computer predictions because of many uncontrollable factors and adverse test conditions such as: line voltage variations, lamp performance, product manufacturing tolerances, jobsite conditions, and other unrecoverable light-loss factors. THE FIXTURE TYPE(S) AND LAMPING(S) SPECIFIED ON THIS LAYOUT MUST BE USED IN ORDER TO MEET THE EXACT CRITERIA AND PERFORMANCE DATA SHOWN. IES RECOMMENDED ILLUMINANCE TARGETS USED WHERE APPLICABLE. Luminaire Schedule Project: 20200277-JH STATE BANK CARMEL BRANCH - SITE LIGHTING Symbol Calculation Summary Project: 20200277-JH STATE BANK CARMEL BRANCH - SITE LIGHTING Label Qty Label Arrangement Lum. Watts Lum. Lumens CalcType Units Avg Max Min Avg/Min LLF Description Max/Min PARKING LOT & DRIVE @ Grade Illuminance Fc 1.63 9.1 0.1 16.30 91.00 PERIMETER @ Grade Illuminance Fc 0.31 14.0 8 F2 SINGLE 33.8 4530 0.850 0.0 N.A. N.A. RFL3-90L-40-4K7-W PROPERTY LINE @ Grade Illuminance Fc 0.34 1 H-24' GROUP N.A. N.A. 0.880 HP-4-WL-D-24ft-H-840-F 6 R2 SINGLE 17.2 1416 0.880 SS4G4DSL3408 _ICS432HZ-PR 7 S1 SINGLE 31 2671 0.850 WO877-XX-LED 3 V6 SINGLE 82.32 6999 0.850 VP-S-36L-80-4K7-4-BC 1 W1 SINGLE 37 4705 1.000 070533 2.5 0.0 N.A. N.A. STAIRS BASE @ Grade Illuminance Fc 25.68 26.7 24.9 1.03 1.07 STAIRS DOWN @ Floor Illuminance Fc 11.03 25.6 0.7 15.76 36.57 03/15/21