Loading...
HomeMy WebLinkAboutS001.0Layout Name 57 Gramercy Description 9800 - C Created March 16, 2021 Revised March 24, 2021 Builder David Weekly Sales Rep Designer Juan Varela Contract Lumber 200 Schofield Drive Columbus , OH 43213 614.751.1109 2nd Floor I Joist Label Description Width Depth Qty Plies Pcs Length J2 LPI 20Plus 2.5 14 5 13-1-2 J3 LPI 20Plus 2.5 14 14 21-9-12 J4 LPI 20Plus 2.5 14 6 16-11-2 J5 LPI 20Plus 2.5 14 7 19-5-2 J6 LPI 20Plus 2.5 14 12 13-9-12 J7 LPI 20Plus 2.5 14 3 19-9-4 F2 LPI 20Plus 2.5 14 1 2 2 21-9-12 F4 LPI 20Plus 2.5 14 1 2 2 19-5-2 LVL/LSL Label Description Width Depth Qty Plies Pcs Length F1 LP-LVL 2900Fb-2.0E 1.75 14 1 8-0-0 F3 LP-LVL 2900Fb-2.0E 1.75 14 1 10-0-0 F5 LP-LVL 2900Fb-2.0E 1.75 14 1 3 3 18-0-0 D1 LP-LVL 2900Fb-2.0E 1.75 16 1 2 2 22-0-0 Rim Board Label Description Width Depth Qty Plies Pcs Length R1 LP APA Rated OSB 1.125 X 14 1.125 14 12 12-0-0 Lumber Label Description Width Depth Qty Plies Pcs Length D2 SP #2 1.5 5.5 3 4-0-0 D3 SP #2 1.5 7.25 3 4-0-0 DB1 SP #2 1.5 7.25 2 2 4 10-0-0 J1 SP #2 1.5 7.25 7 8-0-0 Hanger Beam/Girder Supported Member Label Pcs Description Skew Slope fasteners fasteners 1 Unknown Hanger H1 1 ITS1.81/14 2 10d H2 18 IUS2.56/14 (Max) 14 10dx1 1/2 2 10dx1 1/2 H3 1 MIU5.12/14 (Max) 22 16d 6 10dx1 1/2 H4 6 LU26 6 10dx1 1/2 4 10dx1 1/2 H6 1 IUS1.81/14 (Max) 14 10d 2 10dx1 1/2 2nd Floor Design Method ASD (USA) Building Code IRC 2018 Floor Loads Live 40 Dead 10 Deflection Joist LL Span L/ 480 TL Span L/ 240 LL Cant 2L/ 480 TL Cant 2L/ 240 Deflection Girder LL Span L/ 480 TL Span L/ 240 LL Cant 2L/ 480 TL Cant 2L/ 240 Decking Decking OSB 23/32 APA Rated Sturd- I-Floor Fastener Nailed & Glued General Notes - It is the sole responsibility of the builder/installer to follow this layout exactly. Notify Contract Lumber of any discrepancies between this layout and field conditions. Contract Lumber is not liable for any field changes without prior approval. - Refer to details in the installation guide prior to construction10" 10"10"1'10"1'4" 2x6 BRG. WALL HOLD OFF 12"2 JACKS REQUIREDEA. END2 JACKS REQUIREDEA. ENDE1N A3 A3 A7A7 A3 A7 10" HOLE CHASE 10" HOLE CHASE 10" HOLE CHASE10" HOLE CHASE10" HOLE CHASE10" HOLE CHASESE EMPIEZA AQUISTART LAYOUT16" O.C.16" O.C. SE EMPIEZA AQUI START LAYOUT EXTRA JOISTUNDER ISLANDSHIFT JOIST 1"TO AVOID PLBG2 JACKS REQUIREDEA. END3-2X6 3-2X6J4J4 @ 16"J4J5 @ 16"J7 @ 16" J2 @ 16"J2 J33 X J3 3 X J3 J3 @ 8"J3 J3 J6 @ 16"J1 @ 16"F2 ( 2 ply )F4 ( 2 ply )DB1 ( 2 ply ) DB1 ( 2 ply ) F5 ( 3 ply ) F3 ( 1 ply )F1 ( 1 ply )D3 ( 1 ply )D3 ( 1 ply )D3 ( 1 ply )D1 ( 2 ply ) D2 ( 1 ply )D2 ( 1 ply ) D2 ( 1 ply ) H6 H2H3 H2 H4H1 H2Reviewed By: LAYOUT NOT TO SCALE Roof GIRDER TRUSS GIRDER TRUSS HIP TRUSSHIP TRUSSDB1 ( 2 ply )DB1 ( 2 ply ) D2 ( 1 ply ) D2 ( 1 ply )D2 ( 1 ply ) D2 ( 1 ply )D2 ( 1 ply )D2 ( 1 ply ) D2 ( 1 ply ) D2 ( 1 ply )D2 ( 1 ply )D2 ( 1 ply ) D2 ( 1 ply )Roof Lumber Label Description Width Depth Qty Plies Pcs Length D2 SP #2 1.5 5.5 11 4-0-0 DB1 SP #2 1.5 7.25 2 2 4 10-0-0 Version 20.60.158Powered by iStruct This layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them 03/29/21