Loading...
HomeMy WebLinkAboutS500.22 FRAMING SECTION BLOWN INSUL. R-19 2 CAR GARAGE ELEVATOR 24" OPEN WEB JST @ 16" O.C. 1'-512" 23'-1012" 1'-112"1'-434" 4'-8"10'-118" 2'-3516"HEELHEIGHTTOP OF MAIN LEVEL SUB FLOOR 2 PLY"x16" LVL HDR.534" 3 PLY"x914" LVL HDR. 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI 12"X22" DEEP CONCRETE FOOTING @ 2500 PSIHEELHEIGHTSTEPR-10 RIGID INSULATION 10'-118"R-38 BATTS 8"ELEVATOR 8'-634" 3'-718"PLYWOOD HANGER =14 RISERS@7516" EA.13 TREADS @ 11" EA.= 10'-118" 2'-034" 9'-118" 2'-034" 9'-118"12 PITCH 14 "1'-6"1'-1118"1014" 23'-10" 1014" TRUSSES 24" o.c. T.C. L.L. 30 PSF T.C. D.L. 10 PSF B.C. D.L. 10 PSF B.C. L.L. 0 PSF TOTAL 50 PSF NOTE: TRUSS DESIGN BY MFG. 16" LVL JST @ 16" O.C. 3 4" PLYWD SUB. FL. 3 4" PLYWD SUB. FL. 6 MIL POLYETHYLENE VAPOR BARRIER 4" CONC. SLAB W/ 6x6 #10 WWF 4" (MIN.) GRAVEL FILL 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI NOTES: - VERIFY ROOF MATERIAL, SLOPE, DRAINS & DOWNSPOUTS w/ CONTRACTOR. - GAF TPO 60 MILL. RUBBER ROOF FULL THK FRICTION FIT FIBERGL INSUL. BATTS R-19 2x6 STUDS 16" O.C. w/ 1 2" DRYWALL 6 MIL POLYETHYLENE VAPOR BARRIER4" (MIN.) GRAVEL FILL 4" CONC. SLAB W/ 6x6 #10 WWF 3 4" PLYWD DECKING 12 PITCH6 TRUSSES 24" o.c. T.C. L.L. 30 PSF T.C. D.L. 10 PSF B.C. D.L. 10 PSF B.C. L.L. 0 PSF TOTAL 50 PSF NOTE: TRUSS DESIGN BY MFG. NOTE: EXTERIOR WALL, FLASHING & WATERPROOFING AS PER CONTR. 12 BATH STORAGE 2x10'S 16" O.C.OFFICE/BEDROOM #2 BATHROOM PANTRY DROP ZONE CLOSET DINING AREA ENTRY FOYER 4'-1114" 2 PLY"x24" FLUSH LVL HDR. W/ JST HANGER 2x10'S 16" O.C.11'-378" 10" 2'-9" DRAFT STOP NOTES: - GAF TPO 60 MILL. RUBBER ROOF - VERIFY ROOF MATERIAL W/ CONTRACTOR. THICKEN SLAB11'-2116"RECESSED 8" VERIFY w/ ELEVATOR MANUFACTURER/ CONTRACTOR FOR SPECS. 24" OPEN WEB JST @ 16" O.C. BOT. OF LOOKOUTS METAL CAP SPECIFIED BY CONTRACTOR NOTE: EXTERIOR WALL, FLASHING & WATERPROOFING AS PER CONTR. NOTE: EXTERIOR WALL, FLASHING & WATERPROOFING AS PER CONTR. METAL CAP SPECIFIED BY CONTRACTOR 812" 312" 5"512"9" NOTE: WINDOW HEAD & SILL, FLASHING & WATERPROOFING AS PER CONTR. 12'-3" 3" TREADS 1'-014" 4'-5" 2x10'S 16" O.C. 34" MC 12x10.6 STRINGER W/1 8" CLOSURE PLATE WELDED AND GROUND SMOOTH 2"x2"x 1 4" STOCK Date: 02-09-2021Plan number #201112Designed For:Tim and Connie Glass- HAM 41 -H. G. McCULLOUGH DESIGNERS, INCCONSTRUCTION DRAWINGS BY:- 2146 Glenview Drive, Evansville, IN 47720 - Email: designers@hgmccullough.com- Telephone: 812 . 428 . 0174 - www.hgmccullough.comMake yourself at homeMcKENZIECOLLECTION.COM4631 Lisborn Drive Carmel, IN 46033317.574.7617 PMEDIA/LOFT 7/16" O.S.B. SHEATHING AIR SPACE BRICK VENEER DRAFT STOP DRAFT STOP 13 RISERS@61516 " EA.=5 TREADS @ 11" EA.= 3 FRAMING SECTION R-10 RIGID INSULATION 4" CONC. SLAB PLYWOOD HANGER KITCHEN CLOSET 2 PLY"x16" FLUSH LVL HDR. w/ JST HANGERS 16" LVL JST @ 16" O.C. 3 4" PLYWD SUB. FL. 6 MIL POLYETHYLENE VAPOR BARRIER 4" CONC. SLAB W/ 6x6 #10 WWF 4" (MIN.) GRAVEL FILL W18x71# FLUSH STEEL BEAM W/ JST. HANGERS 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI R-38 BATTS FULL THK FRICTION FIT FIBERGL INSUL. BATTS R-19 2x6 STUDS 16" O.C. w/ 1 2" DRYWALL 3 4" PLYWD DECKING4'-8"1'-112" 512" 3'-978"MECHANICALS /STORAGE 12'-038"METAL CAP FIREPLACE NOT SHOWN 42" GAS DIRECT VENT - THIN BRICK ON ALL 4 SIDES - FIREBOX 18" OFF THE FLOOR - NO HEARTH-RAISED - MEDIA ABOVE STORAGE DOORS OVERHANG INSUL. BATTS INSUL. BATTS 24" OPEN WEB JST @ 16" O.C. AIR SPACE BRICK VENEER 34"3'-534"=6 RISERS@7516" EA.5'-214"4'-714"138"2 PLY"x24" FLUSH LVL HDR. W/ JST HANGER 8'-818"TRUSSES 24" o.c. T.C. L.L. 30 PSF T.C. D.L. 10 PSF B.C. D.L. 10 PSF B.C. L.L. 0 PSF TOTAL 50 PSF NOTE: TRUSS DESIGN BY MFG. TOP OF TRUSS FULL THK FRICTION FIT FIBERGL INSUL. BATTS R-15 2x4 STUDS 16" O.C. w/ 1 2" DRYWALL 4 FRAMING SECTION 6 MIL POLYETHYLENE VAPOR BARRIER4" (MIN.) GRAVEL FILL 4" CONC. SLAB W/ 6x6 #10 WWF ZIP WALL W/ TAPPED JOINTS 7/16" O.S.B. SHEATHING AIR SPACE BRICK VENEER ASPHALT SHINGLES 7 16 " DECKING 15# ASPHALT SAT. FELT, EXCEPT IN HIGH RISK AREAS USE ICE & WATER SHIELD MEMBRANE 12 PITCH 6 2 CAR GARAGE 16'-712" 1'-512"10'-118" 2'-3516" 8'-334"BLOWN INSUL. R-19 11'-2116"HEELHEIGHTFULL THK FRICTION FIT FIBERGL INSUL. BATTS R-11 HARDI PANEL w/ TRIM 16'-712" 1'-512" TOP OF THIRD LEVEL SUB FLOOR 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI BOT. OF LOOKOUTS 912"21316" SCALE: 1/4"=1'-0"ELEVATIONS NOT FOR CONSTRUCTION PRELIMINARY CONSTRUCTION DRAWINGS ONLY NOT TO BE USED FOR STRUCTURAL PURPOSES "C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction of this work, its technical aspects or creative content without the express written consent of H. G. McCullough Designers, Inc. This work is fully protected by copyright under U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc."9Drawings & blueprints are intended solely as a plan layout& basis for materialestimate. H.G. McCullough Designers Inc.assumes no responsibility for structuralor material adequacy of drawings nor for compliance with appropriate building codes.H.G. McCullough Designers Inc. is not liable for, nor does it guarantee or controlcontractor or subcontractor's performance, nor their errors or omission. Customersshould have qualified engineer or architect review construction detailsSHEET NUMBER 04/01/21