HomeMy WebLinkAboutPlan Set - TolliverSHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. A0 PROJECT INFO VICINITY MAP PROJECT SITE PROJECT SITE OWNER: DAMION TOLLIVER ADDRESS:13201 DITCH RD CARMEL, IN 46032 PHONE: 317-413-6411 EMAIL: DAMIONDT@HOTMAIL.COM APN:290927000001107018 (HAMILTON COUNTY) CONSTRUCTION TYPE:VB OCCUPANCY TYPE:R3- RESIDENTIAL SHEET INDEX A1 SITE PLAN, PROJECT INFO A2 MOUNTING ROOF PLAN E1 SINGLE LINE DIAGRAM E2 ELECTRICAL CALCULATIONS E3 REQUIRED SIGNAGE E4 MODULE DATA SHEET E5 RAPID SHUTDOWN DATA SHEET E6 INVERTER DATA SHEET E7 OPTIMIZER DATA SHEET S1 STANCHION DATA SHEET S2 RACKING DATA SHEET S3 RACKING ENGINEERING S4 RACKING GROUNDING S5 RACKING CERTIFICATION APPLICABLE CODES 2014 IN BUILDING CODES 2020 IN RESIDENTIAL CODES 2012 IN PLUMBING CODES 2014 IN MECHANICAL CODES 2011 NEC (NFPA 70) 2012 INTERNATIONAL FIRE CODE 23.700 DC kW PV SOLAR STRING INVERTER SYSTEM - ROOF MOUNT WITH BATTERY BACKUP TOLLIVER RESIDENCE VICINITY MAP SOLAR PHOTOVOLTAIC SYSTEM NOTES AERIAL VIEW SERVICE: EXISTING 200A MAIN SERVICE PANEL 13201 DITCH RD CARMEL, IN 46032 · ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER’S INSTRUCINSTRUCTIONS, NEC 110.2, 110.3, 690.4(B) AND 690.12(5). · ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. · ALL PV CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES, NEC 690.9(A). · ALL EQUIPMENT OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN INITIATION) SHALL BE LOCATED NEAR THE MAIN ELECTRICAL SERVICE EQUIPMENT, NEC 690.13, 690.15. · RAPID SHUTDOWN EQUIPMENT TO PROVIDE CONTROLLED CONDUCTORS THAT ARE MORE THAN 5 FEET IN LENGTH INSIDE A BUILDING OR MORE THAN 10 FEET FROM A PV ARRAY LIMITATION TO NOT MORE THAN 30 VOLTS AND 240 VOLT-AMPERES WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION, NEC 690.12. · THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEENRESTORED, NEC 690.61 & 705.40. · DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER EXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH OPAQUE COVERING,NEC 690.18. · ALL CONDUCTOR EXPOSED TO WEATHER SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT, NEC310.10(D) AND 690.31(C) THROUGH (G). · ALL CONDUCTORS TO BE OF MATERIAL APPROVED BY THE CODE AND THEIR INSULATIONS TO BE RATED TO NOTLESS THAN 90OC 600-VOLTS MINIMUM · INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR GROUNDED DC SYSTEMS,NEC 690.31(B); AND PV-WIRE TYPE FOR UNGROUNDED DC SYSTEMS, (AS IN TRANSFORMERLESS INVERTERS OR MICROINVERTERS WITH ISOLATED GROUNDS), NEC 690.35(D). · FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS AND TERMINALS LISTED AND MARKED FOR THE USE, NEC 110.14 & 690.74(A). · ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END FOR UNIQUE IDENTIFICATION, NEC 690.31(B). · ALL GROUNDED, (NEUTRAL), CONDUCTORS’ INSULATION SHALL BE SOLID WHITE, GRAY, OR WITH 3-WHITE STRIPES, NEC 200.6, 200.7, & 400.22; AND ALL GROUNDING CONDUCTORS SHALL BE OF BARE WIRE WITHOUT COVERING, OR WITH INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, NEC 250.119 & 400.23. THE COLOR OF UNGROUNDED CONDUCTORS SHALL BE OTHER THAN FOR GROUNDED, (NEUTRAL) · MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND OVERCURRENT PROTECTION IS 10 FEET, NEC 705.31 · CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT ANY DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL MEET THE FOLLOWING, NEC 705.12(D). · DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, OR CABLE SHEATHINGS, NEC 690.31(G) · RACEWAYS IN ENCLOSED PORTIONS OF THE BUILDING MUST RUN ALONG BOTTOM OF LOAD BEARING MEMBERS, · METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE SHEATHS CONTAINING CIRCUITS OVER 250-VOLTS TO GROUND MUST BE BONDED IN ACCORDANCE WITH NEC 250.97 & 290.92(B). · FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR THAT ARE IDENTIFIED AND LISTED FOR SUCH USE, NEC 690.31(H) & 110.14. · CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30 VOLTS SHALL REQUIRE TOOL TO OPEN AND MARKED “DO NOT DISCONNECT UNDER LOAD” OR “NOT FOR CURRENT INTERRUPTING”, NEC 690.33(C) & (E)(2). · EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6 AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR, NEC 690.46 & 250.120(C). · THE INTERCONNECTION POINT SHALL BE ON THE LINE SIDE OF ALL GROUND-FAULT PROTECTION EQUIPMENT, NEC 705.32. · DC PV SOURCE OR DC PV OUTPUT CIRCUITS SHALL BE CONTAINED IN METAL RACEWAYS, TYPE MC CABLE OR METALLIC ENCLOSURES WHEN INSIDE THE BUILDING, NEC 690.31(G). · CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT LOCATED UNDER THE MODULES, MUST BE PROTECTED, NEC 300.4. · PROPOSED LOCATIONS OF ELECTRICAL SERVICE REPLACEMENTS MUST ALSO BE APPROVED BY THE ELECTRICAL UTILITY COMPANY. · FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPES OF NATURAL GAS, HOT WATER, AND COLD WATER MUST BE PROVIDED, NEC 250.104. · GROUNDING ROD ELECTRODES SHALL BE INSTALLED 8’ MINIMUM IN CONTACT WITH SOIL, NEC 250.53(G). · ALL EXTERIOR CONDUITS SHALL BE PAINTED TO MATCH THE COLOR OF THE SURROUNDING AREA (ROOF, SIDING, AND STUCCO). · EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, & VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED OR BLOCKED BY THE SOLAR PHOTOVOLTAIC SYSTEM. · EXISTING DWV PLUMBING VENT TERMINATIONS THAT ARE HORIZONTALLY LOCATED CLOSER THAN 12” FROM THE PROPOSED MODULES, MUST BE REROUTED, OR MUST BE EXTENDED A MINIMUM OF 6” ABOVE THE SURFACE OF THE MODULES · EXISTING B-VENT TERMINATIONS, FOR FUEL BURNING APPLIANCES, WHERE ADJACENT TO THEPROPOSED MODULES, MUST BE EXTENDED 12” ABOVE THE MODULES’ TOP SURFACE · THE MARKINGS, “WARNING: PHOTOVOLTAIC POWER SOURCE”, FOR DC RACEWAYS AND CABLE ASSEMBLIES MUST BE AT 10’ O.C.; AND BENDS, ABOVE OR BELOW PENETRATIONS OF ROOFS, CEILINGS, WALLS, OR BARRIERS, NEC 690.31(G)(4). · PV COMBINER PANELBOARDS MUST HAVE PERMANENT MARKINGS INDICATING THAT THEY ARE DEDICATED FOR PV CIRCUITS ONLY NO LOADS ARE TO BE CONNECTED. · WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTING ELECTRICAL EQUIPMENT, NEC 110.26. · RESIDENTIAL TYPE PV CIRCUITS OVER 150-VOLTS TO GROUND MUST NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED, NEC 690.7(D). · A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH CAL-OSHA REGULATIONS. · ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BE INSTALLED ON ALL EQUIPMENT PRIOR TO ANY INSPECTIONS. · LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 3/8’’ IN WHITE ON A RED BACKGROUND. · WHEN THE MAIN CIRCUIT BREAKER IS DERATED, A PERMANENT MARKING MUST BE PROVIDED ON THE PANELBOARD TO INDICATE THAT THE MAIN CIRCUIT BREAKER HAS BEEN DOWNSIZED TO _______AMPS, DO NOT UPSIZE IT. · GROUND-MOUNTED PV SYSTEMS MUST HAVE A CLEAR, BRUSH-FREE AREA OF 10-FEET AND A FIRESEPARATION DISTANCE OF 5-FEET MINIMUM TO OTHER STRUCTURES AND PROPERTY LINES PROJECT SCOPE INSTALLATION OF ROOF MOUNT SOLAR PV SYSTEM DERATE 200A MAIN BREAKER TO 150A NEW EQUIPMENT: 60 MODEL#: TSM-395DEG15HC.20(II) TRINA SOLAR MODULES WITH PV LINK 2502 PER STRING 2 X7602 [240V] GENERAC POWER SYSTEMS 3 PWRCELL 17, 17.1KWH 6X BATTERY MODULEBY GENERAC POWER SYSTEM SIZE: 23.700 DC kW RATING 21.388 CEC AC RATING ARRAY AREA: 22.11 SQFT x 60 = 1326.67 SQFT GENERAL NOTES 1. WORKING CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT SHALL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. 2. PV EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL ONLY BE INSTALLED BY QUALIFIED PERSONS. CEC 690.4 (E) 3. ROOFTOP MOUNTED PV SYSTEM PANELS AND MODULES SHALL MEET A MINIMUM FIRE CLASSIFICATION AS REQUIRED BY R902.4 AND CBC 1505.9. 4. ROOF ACCESS POINTS. ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS (R331.4.1).LADDERS SHALL BE OSHA APPROVED AND SECURED TO THE STRUCTURE FOR INSPECTION PURPOSES.CONTRACTORS ARE REQUIRED TO BE PRESENT FOR THE FIRST AND/OR FINAL INSPECTIONS. 5. APPROVED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED WITHIN THE DWELLING UNIT AND SHALL BE FIELD VERIFIED EITHER THROUGH FINAL BUILDING INSPECTION. SMOKE ALARMS ARE REQUIRED TO BE INSTALLED IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. R314.1, R315.1 6. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. 04/01/21 D MSP MATS INV BATSUB INV BAT BATSUB SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. A1 SITE PLANLEGEND: (E) - EXISTING (N) - NEW SITE PLAN SCALE: 1" = 50' (E) 1 - STORY 5962 SQFT N S EW INSIDE BARN (N) 2 - 7.6KW 1Ø, PWRCELL INVERTER WITH CTS, MODEL APKE00014 CERTIFICATION MODEL: X7602 BY GENERAC POWERD IT C H R DINSIDE HOUSE (E) 200A MAIN SERVICE PANEL APN: 290927000001107018 (N) 60 - MODEL#: TSM-395DEG15HC.20(II) TRINA SOLAR MODULES WITH PV LINK 2502 PER STRING WITH GENERAC SNAP RS MODEL: APKE00011 CERTIFICATION MODEL: RS801 RAPID SHUTDOWN DEVICE PER MODULE PROPERTY LINE (E) UTILITY METER (N) 100A AC DISCONNECT INSIDE BARN (N) 1 - 125A BACKUP LOADS SUBPANEL BARN (E) DRIVEWAYINSIDE BARN (N) 3 - PWRCELL 17, 17.1KWH 6X BATTERY MODULE BY GENERAC POWER PROPERTY LINE (E) DRIVEWAY (N) 200A AUTO TRANSFER SWITCH INSIDE BARN (N) 125A PV COMBINER SUBPANEL 04/01/21 3'INV JB BATSUB INV BAT BATSUB JB 50'6" MAX6" MAXD MSP MATS A2 MOUNTING PLAN SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC.MOUNTING PLAN SCALE: 3/32" = 1'-0" LEGEND (E) EXISTING (N) NEW CONDUIT RUN VIF VERIFY IN FIELD JUNCTION BOX MAIN SERVICE PANEL SUBPANEL INVERTER UTILITY METER AC DISCONNECT MSP JB N S EW SUB METAL ROOF 2 X 6 TRUSS @ 24" ON CENTER ATTACHMENTS @ 48" ON CENTER MODULES COVER 13.9% OF THE ROOF AREA INV 104 TOTAL ATTACHMENTS @ 4FT OC MAX D M SOLAR PANEL DEAD WEIGHT CALCULATION RACKING MANUFACTURER IRONRIDGE FLUSH MOUNT AND XR100 RAILS MODULE TRINA SOLAR MODULE TOTAL # OF MODULES 60 MOUNTING SYSTEM WEIGHT 401.88 LBS MODULE WEIGHT 59.1 LBS TOTAL SOLAR MODULE WEIGHT 3546.00 LBS MODULE LENGTH 80.00 INCHES TOTAL PANEL WEIGHT CALCULATION 3947.88 LBS MODULE WIDTH 39.80 INCHES POINT LOAD CALCULATION 37.96 LBS MODULE AREA 22.11 SQFT TOTAL SOLAR MODULE AREA 1326.67 LBS TOTAL# OF ATTACHMENTS 104 DISTRIBUTED LOAD CALCULATION THE POINT LOADING AND DISTRIBUTED LOADING SHOULD BE MAX 5 LBS/FT2 2.98 PSF RACKING WEIGHT .68 LBS / LN FT ROOF COVERAGE TOTAL MODULE AREA 1326.67 13.9% </= 50% = OK ROOF FACE AREA 9519 ROOF COVERAGE (%) 13.9 FIRE ACCESS POINT (NOT TO BE OVER ANY DOORS, WINDOWS OR OTHER OBSTRUCTIONS) (N) 60 - MODEL#: TSM-395DEG15HC.20(II) TRINA SOLAR MODULES WITH PV LINK 2502 PER STRING WITH GENERAC SNAP RS MODEL: APKE00011 CERTIFICATION MODEL: RS801 RAPID SHUTDOWN DEVICE PER MODULE 8 STRINGS WITH 1 - PV LINK PER STRING S-5! PROTEA BRACKET TRAPEZOIDAL METAL ROOF TYP. ANCHOR DETAIL NOT TO SCALE MODULE SIDE VIEW IRONRIDGE RAILS EXISTING PURLINS EXISTING PURLINS FRONT VIEW MODULE S-5! PROTEA BRACKET 180° AZIMUTH 30° SLOPE INSIDE BARN (N) 2 - 7.6KW 1Ø, PWRCELL INVERTER WITH CTS, MODEL APKE00014 CERTIFICATION MODEL: X7602 BY GENERAC POWER INSIDE HOUSE (E) 200A MAIN SERVICE PANEL (E) UTILITY METER (N) 100A AC DISCONNECT INSIDE BARN (N) 1-125A BACKUP LOADS SUBPANEL INSIDE BARN (N) 3 - PWRCELL 17, 17.1KWH 6X BATTERY MODULE BY GENERAC POWER (N) 200A AUTO TRANSFER SWITCH INSIDE BARN (N) 125A PV COMBINER SUBPANEL (N) 3/4" EMT CONDUIT RUN ABOVE ROOF 04/01/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. E1 ELECTRICAL LINE DIAGRAM MODULE SPECIFICATION MANUFACTURER TRINA SOLAR MODEL NO.TSM-395DEG15HC. 20(II) PEAK POWER 355W RATED VOLTAGE (Vmp) 36.4 V RATED CURRENT (Imp) 9.77 A OPEN CIRCUIT VOLTAGE (Voc) 43.6 V SHORT CIRCUIT CURRENT (Isc) 10.47 A INVERTER SPECIFICATION INVERTER MAKE GENERAC POWER INVERTER MODEL NO. MODEL APKE00014 CERTIFICATION MODEL: X7602 MAX INPUT VOLTAGE 380V MAX INPUT CURRENT 20A NOMIMAL AC VOLTAGE 240 V MAX AC CURRENT 32A M (E) UTILITY METER SERVICE LOAD CALCULATIONS BACKFED 120% RULE - PER 705.12 (D) BUS RATING SIZE MUTIPLIER (120%) RESULT 200 1.20 240 MCB DERATE INVERTER AC OUTPUT +125%RESULT 150 80.00 230.00 240A >/= 230A = OK CEC 705.12(D)(2)(3)(B) WHERE TWO SOURCES, ONE A UTILITY AND THE OTHER AN INVERTER, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125% OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120% OF THE AMPACITY OF THE BUSBAR. (N) 7.6KW 1Ø, PWRCELL INVERTER WITH CTS MODEL APKE00014 CERTIFICATION MODEL: X7602 BY GENERAC POWER MAX AC OUTPUT CURRENT 32A 4X - 30A PORTS G POWER CORE DC(N) JBOX NEMA 3R C F RELOCATE PARTIAL LOADS TO 125A BACKUP LOAD SUBPANEL (N) 100A AC DISCONNECT G SOLAR GROUND TYING INTO THE EXISTING UFER GROUND POINT (N)125A PV SUBPANEL COMBINER (N)40A (N)40A PV OCPD PV OCPD (N) 7.6KW 1Ø, PWRCELL INVERTER WITH CTS MODEL APKE00014 CERTIFICATION MODEL: X7602 BY GENERAC POWER MAX AC OUTPUT CURRENT 32A 4X - 30A PORTS G POWER CORE DCB G N G (N) 125A BACKUP LOADS SUBPANEL D D 125% OF INVERTER MAX AC OUTPUT MAX AC OUTPUT (AMPS)125%RESULT (AMPS)OCPD SIZE 64 1.25 80.00 80A (N)80A (E) EARTH GROUND (N) 150A MCB DERATE PV OCPD G N (N)125A (E) 200A MAIN SERVICE PANEL 240V, 1P, 3W C (N) PWRCELL 17, 17.1KWH 6X BATTERY MODULE BY GENERAC POWER B WIRE/CONDUIT SCHEDULE @ 90° AMPACITY TAG DESCRIPTION CONDUCTOR TYPE/SIZE/QUANTITY CONDUIT SIZE/TYPE A ARRAY TO JBOX (4) #10 PV WIRE (2+ & 2- ) & #6 AWG SOLID COPPER (EGC) FREE AIR B JBOX TO INVERTER (4) #10 AWG THHN-2 (2+ & 2-) & (1) #8 AWG THHN-2 (G) 3/4" EMT C INVERTER TO BATTERY (2) #10 AWG THHN-2 (1+ & 1-) & (1) #8 AWG THHN-2 (G) 3/4" EMT D INVERTER TO PV SUBPANEL (3) #8 AWG THHN-2 (L1, L2 & N) & (1) #8 AWG THWN-2 (G) 3/4" EMT E INVERTER TO BACKUP LOADS (3) #8 AWG THHN-2 (L1, L2 & N) & (1) #8 AWG THWN-2 (G) 3/4" EMT F PV SUBPANEL TO AC DISCONNECT (3) #3 AWG THHN-2 (L1, L2 & N) & (1) #8 AWG THWN-2 (G)1" EMT & 1" SCHED 40 PVC G AC DISCO TO MAIN SERVICE (3) #3 AWG THHN-2 (L1, L2 & N) & (1) #8 AWG THWN-2 (G)1" EMT & 1" SCHED 40 PVC H BACKUP LOADS TO ATS (3) #2 AWG THHN-2 (L1, L2 & N) & (1) #6 AWG THWN-2 (G)1-1/4" EMT & 1-1/4" SCHED 40 PVC I ATS TO MAIN SERVICE (3) #3/0 AWG THHN-2 (L1, L2 & N) & (1) #4 AWG THWN-2 (G) 2" EMT C H (N) 30 - TSM-395DEG15HC.20(II) TRINA SOLAR MODULES WITH PV LINK 2502 PER STRING WITH GENERAC SNAP RS MODEL: APKE00011 CERTIFICATION MODEL: RS801 RAPID SHUTDOWN DEVICE PER MODULE ... PV LINK OPTIMIZERS S2502 MODEL#: APKE00010 7 A 8 7 8 ... 7 A 8 7 8 (N) 200A AUTO TRANSFER SWITCH (N)50A (N)50A E E EXISTING WIRES & CONDUIT (N) PWRCELL 17, 17.1KWH 6X BATTERY MODULE BY GENERAC POWER (N) JBOX NEMA 3R PV LINK OPTIMIZERS S2502 MODEL#: APKE00010 (N) 30 - TSM-395DEG15HC.20(II) TRINA SOLAR MODULES WITH PV LINK 2502 PER STRING WITH GENERAC SNAP RS MODEL: APKE00011 CERTIFICATION MODEL: RS801 RAPID SHUTDOWN DEVICE PER MODULE H 04/01/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. E2 ELECTRICAL CALCULATIONS LOCATION INFORMATION HIGH TEMP 35° LOW TEMP -22° VOLTAGE CORRECTION FACTOR 1.12 ROOF TEMP + 22° 57° TEMP CORRECTION FACTOR (EXPOSED) 0.71 TEMP CORRECTION FACTOR (CONDUIT) 0.96 OPTIMIZERS SPECIFICATION MAKE PV LINK 2502 MAXIMUM INPUT DC POWER 2500V ABSOLUTE MAX INPUT VOLTAGE (VOC)420V MAX INPUT SHORT CIRCUIT CURRENT (ISC)18A MAX OUTPUT VOLTAGE 420V INVERTER SPECIFICATION INVERTER MAKE GENERAC POWER INVERTER MODEL NO. MODEL APKE00014 CERTIFICATION MODEL: X7602 MAX INPUT VOLTAGE 420V MAX INPUT CURRENT 20A NOMIMAL AC VOLTAGE 240 V MAX AC CURRENT 32A DC CONDUCTOR AMPACITY CALCULATIONS ARRAY TO JUNCTION BOX (CEC ART 310.15) A EXPECTED WIRE TEMPERATURE (FREE AIR) 35 CELSIUS B ADD 22°C OR 4O°F FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOF 57 CELSIUS TEMPERATURE CORRECTION FACTOR CEC TABLE 310.15 (B)(2)(A)0.71 C # OF CURRENT CARRYING CONDUCTORS 4 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) D CONDUIT FILL CORRECTION 0.80 .80 (FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00 (FOR 3 OR LESS CONDUCTORS IN CONDUIT) CEC TABLE 310.15 (B)(3)(A) E CIRCUIT CONDUCTOR SIZE #10 AWG MINIMUM #10 AWG CU, 90°C WET (USE-2, PV WIRE, THWN-2, RHW-2) F CIRCUIT CONDUCTOR AMPACITY 40 AMPS CEC TABLE 310.15 (B)(16) G REQUIRED CIRCUIT CONDUCTOR AMPACITY 18 AMPS OPTIMIZER ISC H DERATED AMPACITY OF CIRCUIT CONDUCTOR 22.72 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY CEC TABLE 310.15 (B)(2)(A) NOTE: "H" MUST BE LARGER THAN "G" 22.72A > 18.00A = OK DC CONDUCTOR AMPACITY CALCULATIONS FROM JUNCTION BOX TO INVERTER A AMBIENT TEMPERATURE ADJUSTMENT EXPOSED CONDUIT 57 CELSIUS (ADD 22° OR 4O° FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOF) CEC TABLE 310.15 (B)(2)(A) & CEC TABLE 310.15 (B)(2)(C) EXPECTED WIRE TEMPERATURE TEMPERATURE CORRECTION FACTOR 0.71 CEC TABLE 310.15 (B)(2)(A) # OF CURRENT CARRYING CONDUCTORS 4 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) CONDUIT FILL CORRECTION 0.80 .80 (FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00 (FOR 3 OR LESS CONDUCTORS IN CONDUIT) CEC TABLE 310.15 (B)(3)(A) CIRCUIT CONDUCTOR SIZE #10 AWG MINIMUM #10 AWG CU, 90°C WET (USE-2, PV WIRE, THWN-2, RHW-2) CIRCUIT CONDUCTOR AMPACITY 40 AMPS CEC TABLE 310.15 (B)(16) B REQUIRED CIRCUIT CONDUCTOR AMPACITY 18 AMPS OPTIMIZER ISC C DERATED AMPACITY OF CIRCUIT CONDUCTOR 22.72 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY CEC TABLE 310.15 (B)(2)(A) NOTE: "C" MUST BE LARGER THAN "B" 22.72A > 18.00A = OK MODULE SPECIFICATION MANUFACTURER TRINA SOLAR MODEL NO. TSM-395DEG15HC.20(II) PEAK POWER 355W RATED VOLTAGE (Vmp) 36.4 V RATED CURRENT (Imp) 9.77 A OPEN CIRCUIT VOLTAGE (Voc) 43.6 V SHORT CIRCUIT CURRENT (Isc) 10.47 A AC CONDUCTOR AMPACITY CALCULATIONS INVERTER TO PV SUBPANEL A AMBIENT TEMPERATURE ADJUSTMENT EXPOSED CONDUIT 57 CELSIUS (ADD 22° OR 4O° FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOF) CEC TABLE 310.15 (B)(2)(A) & CEC TABLE 310.15 (B)(2)(C) EXPECTED WIRE TEMPERATURE TEMPERATURE CORRECTION FACTOR 0.96 CEC TABLE 310.15 (B)(2)(A) # OF CURRENT CARRYING CONDUCTORS 2 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) CONDUIT FILL CORRECTION 1.00 .80 (FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00 (FOR 3 OR LESS CONDUCTORS IN CONDUIT) CEC TABLE 310.15 (B)(3)(A) CIRCUIT CONDUCTOR SIZE #8 AWG MINIMUM #10 AWG CU, 90°C WET (USE-2, PV WIRE, THWN-2, RHW-2) CIRCUIT CONDUCTOR AMPACITY @ 90° 55 AMPS CEC TABLE 310.15 (B)(16) INVERTER'S MAXIMUM AC OUTPUT CURRENT 32 AMPS INVERTER MANUFACTURER SPECIFICATIONS B REQUIRED AC CONDUCTOR AMPACITY 40.00 AMPS REQUIRED AC CONDUCTOR AMPACITY =1.25 X MAXIMUM INVERTER'S OUTPUT CURRENT (AMPS) C DERATED AMPACITY OF CIRCUIT CONDUCTORS 52.80 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY CEC TABLE 310.15 (B)(2)(A) NOTE: "C" MUST BE GREATER THAN "B" 52.80A > 40.00A = OK AC CONDUCTOR AMPACITY CALCULATIONS PV SUBPANEL TO AC DISCONNECT TO MAIN SERVICE A AMBIENT TEMPERATURE ADJUSTMENT EXPOSED CONDUIT 57 CELSIUS (ADD 22° OR 4O° FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOF) CEC TABLE 310.15 (B)(2)(A) & CEC TABLE 310.15 (B)(2)(C) EXPECTED WIRE TEMPERATURE TEMPERATURE CORRECTION FACTOR 0.96 CEC TABLE 310.15 (B)(2)(A) # OF CURRENT CARRYING CONDUCTORS 2 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) CONDUIT FILL CORRECTION 1.00 .80 (FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00 (FOR 3 OR LESS CONDUCTORS IN CONDUIT) CEC TABLE 310.15 (B)(3)(A) CIRCUIT CONDUCTOR SIZE #3 AWG MINIMUM #10 AWG CU, 90°C WET (USE-2, PV WIRE, THWN-2, RHW-2) CIRCUIT CONDUCTOR AMPACITY @ 90° 110 AMPS CEC TABLE 310.15 (B)(16) INVERTER'S MAXIMUM AC OUTPUT CURRENT 64 AMPS INVERTER MANUFACTURER SPECIFICATIONS B REQUIRED AC CONDUCTOR AMPACITY 80.00 AMPS REQUIRED AC CONDUCTOR AMPACITY =1.25 X MAXIMUM INVERTER'S OUTPUT CURRENT (AMPS) C DERATED AMPACITY OF CIRCUIT CONDUCTORS 105.60 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY CEC TABLE 310.15 (B)(2)(A) NOTE: "C" MUST BE GREATER THAN "B" 105.60A > 80.00A = OK 04/01/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. E3 REQUIRED SIGNAGED ITCH RDDRIVEWAY G F SIGNS AND LABEL - CENTRAL/STRING INVERTER SYSTEMS NEC ARTICLES 690 AND 705 REQUIRE THE FOLLOWING LABELS OR MARKINGS BE INSTALLED AT THESE COMPONENTS OF THE PHOTOVOLTAIC SYSTEM: DIRECTORY PLACARD NEC 705.10 & NEC 690.56(B) REQUIRES A PERMANENT PLAQUE OR DIRECTORY DENOTING ALL ELECTRIC POWER SOURCE ON OR IN THE PREMISES OR RAPID FIRE SHUTDOWN EQUIPMENT; INSTALL AT MAIN SERVICE PANEL WARNING: PHOTOVOLTAIC POWER SOURCE NEC 690.31(G)(3)(4) ON ALL INTERIOR AND EXTERIOR PV CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES AND JUNCTION BOXES PROVIDE A SIGN WITH THE FOLLOWING WORDING: H · ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES AND DISCONNECTS ARE MARKED. (CFC 605.11.1, CEC 690.31[E], 690.17 & 690.53 & CRC R324) · THE MARKINGS ON THE CONDUITS, RACEWAYS AND CABLE ASSEMBLIES ARE EVERY 10 FEET, WITHIN ONE FOOT OF ALL TURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOW ALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS AND BARRIERS. (CFC 605.11.1.4, CEC 690.31[E]) · MARKING IS PLACED ADJACENT TO THE MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM WHERE THE DISCONNECT IS OPERATED. (CFC 605.11.1.3 & CRC R324) · THE MARKINGS SAY WARNING: PHOTOVOLTAIC POWER SOURCE AND HAVE 3/8-INCH (9.5 MM) MINIMUM-SIZED WHITE LETTERS ON A RED BACKGROUND. THE SIGNS ARE MADE OF REFLECTIVE WEATHER RESISTANT MATERIAL. (CFC 605.11.1.1, 605.11.1.2 & CRC R324 & CEC 690.31) · WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP, LAMINATE OR MEMBRANE ROOFING MATERIALS IN ROOF AREAS NOT COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT, THE LOCATION OF CIRCUITS SHALL BE CLEARLY MARKED. (CEC 690.4) · REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FOR THE ENVIRONMENT. SIGNAGE NOTES: M SOLAR ARRAY CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINAL. TERMINAL ON BOTH LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.17 AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THE FOLLOWING WORDING: WARNING INVERTER CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE PER NEC 690.64 AND 705.12(D)(4) EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. LOCATED AT BACKFED BREAKER PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE PER NEC690.35(F) WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL FOR SOLAR AC DISCONNECT: SOLAR AC DISCONNECT PROVIDE WARNING LABEL AT THE UTILITY INTERACTIVE INVERTER OR GROUND FAULT INDICATOR STATING: WARNING ELECTRIC SHOCK HAZARD IF THE GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. PLAQUE TO BE INSTALLED ON FACE OF THE UTILITY AC DISCONNECT: PV SYSTEM DISCONNECT FOR UTILITY OPERATION TO BE INSTALLED ON THE FACE OF THE SERVICE METER PANEL: CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT LOCATED AS SHOWN LABEL FOR SOLAR DC DISCONNECT: SOLAR DC DISCONNECT PLAQUE TO BE INSTALLED AT ELECTRIC SERVICE: PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL FOR SOLAR DC DISCONNECT: OPERATING CURRENT OPERATING VOLTAGE MAXIMUM SYSTEM VOLTAGE MAXIMUM SYSTEM CURRENT MAXIMUM INVERTER OUTPUT 9.77 A 218.40 A 261.60 V 16.33 A 32 A A E B C D I J K L BATTERIES INVERTER PV SUBPANEL BACKUP LOADSHOUSE BARN MAIN SERVICE PANEL UTILITY METER AC DISCONNECT ATS CAUTION POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN 04/01/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. E4 MODULE DATA SHEET 04/01/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. E5 RAPID SHUTDOWN DATA SHEET 04/01/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. E6 INVERTER DATA SHEET 04/01/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. E7 OPTIMIZERS DATA SHEET 04/01/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. S1 STANCHION DATA SHEET 04/01/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. S2 RACKING DATA SHEET 04/01/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. S3 RACKING ENGINEERING 04/01/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. S3.1 RACKING ENGINEERING 04/01/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. S3.2 RACKING ENGINEERING 04/01/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. S4 GROUNDING DATA SHEET 04/01/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS TOLLIVER RESIDENCE 13201 DITCH RD CARMEL, IN 46032 23.700 DC kW 21.388 kW CEC-AC Rating STRING INVERTER SYSTEM WITH BATTERY BACKUP DATE DESCRIPTION DATE DRAWN2-20-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. RACKING CERTIFICATION S5 04/01/21