Loading...
HomeMy WebLinkAboutGN000.1LOT SPECIFIED PLAN INFORMATION Customer Name {\C256;* Market Home *, 7261-09700#2} Address{\C256;4505 ANDEAN WAY}{\Fsimplex|c0;\C256;CARMEL}{\C256;IN}{\C256;46074} Community{\Fsimplex|c0;\C256;7261}{\C256;BEAR CREEK EXTENSION}{\C256;7261-09700}{\C256;LOTNUM 123} Plan Features{\C256;Elevation HR3Q} MUNICIPALITY STRUCTURAL ENGINEER APPLICABLE CODES MECHANICAL ENGINEER BUILDING CODE ANALYSIS DESIGN LOADS and CRITERIA AREA CALCULATION (SQ. FT.) \pxt12;{\H0.92593x;BUILDING CODE:\PPLUMBING CODE: \P\pql;MECHANICAL CODE:\PFUEL AND GAS CODE:\P\pq*;ENERGY CODE:\PELECTRICAL CODE:\P\pql;FIRE CODE:\P\pt14;\P\pq*,tz;}1. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY THE REQUIRED DESIGN LOADS WITH GOVERNING CODES AND SITE CONDITIONS. VERIFY WITH THE LOCAL BUILDING AGENCIES THE WIND, SEISMIC, SNOW AND OTHER SPECIAL LOADING CONDITIONS. THE ARCHITECT SHALL BE NOTIFIED IN WRITING OF ALL DISCREPANCIES.\P\pa0.25;2. THERE SHALL BE NO STRUCTURAL CHANGES WITHOUT WRITTEN CONSENT OF THE ENGINEER OF RECORD.{\H0.92593x; } ZONING ORDINANCE: .\PUSE GROUP: .\PCONSTRUCTION CLASS: .\PHEIGHT & AREA: .\POTHER REQUIREMENTS: .\pxt20,28;LIVE LOADS:\P\pt2,r28; Sleeping ___ PSF\P Non-Sleeping ___ PSF\P Ext. Decks & Stairs ___ PSF\P\ptr28;DEAD LOAD: ___ PSF\P\pt2,r27; Guard Rail & Handrail ___ LB \P\pt2,r28; Guard Infill Components ___ PSF\P\ptr28;WIND SPEED: ___ MPH\PROOF LIVE LOAD: ___ PSF\PSNOW LOAD: ___ PSF\PLATERAL LOAD: ___ PCF \pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.} \pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.} SHEET LIST TABLE SHT DESCRIPTION CC.01 Cover Sheet CC.02 Notes - Schedules and Legends CC.03 General Notes A0.01 Foundation - Basement A1.11 1st Floor Plan A1.21 2nd Floor Plan A2.01 Building Section A2.02 Building Section A2.03 Building Section A3.01 Front Elevation A3.02 Left Elevation A3.03 Right Elevation A3.04 Rear Elevation A4.01 Roof Plan U0.01 Basement Utility Plan U1.11 1st Floor Utility Plan U1.21 2nd Floor Utility Plan S-1.0 Structural Plan - Foundation Basement (IN Code) S-2.0 Structural Plan - 1st Floor (IN Code) S-3.0 Structural Plan - 2nd Floor (IN Code)LOT SPECIFIC OPTION SELECTIONSOpt Basement Bath Rough-InOpt. Bedroom 618" Brick Wainscot - Sides and RearOpt Coach Light - Location 1Opt Coach Light - Location 3Opt Double Sink Bowl at Bath 2Elevation HR3QNo OptionBasement Foundation3 Car Side Load GarageMasonry Wrap - Sides and RearOwner's Bath 4IndianaOpt Basement Window Well - Location 1Opt Basement Window Well - Location 3 SQUARE FOOTAGE TOTAL:CONDITIONED - LIVABLE SF 1st Floor 2nd Floor 1840 SF 1437 SF 3277 SF TOTAL:CONDITIONED - NON-LIVABLE SF Basement - Unfinished 1779 SF 1779 SF TOTAL:UNCONDITIONED SF 3 Car Garage Side Front Porch 631 SF 128 SF 759 SF 5816 SF COVER SHEETMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2019 PulteGroup, Inc. PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:05/10/2019 PROJECT TYPE Single Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Woodside 2312.300Home for * Market Home *, 7261-09700#24505 Andean Way, Carmel, IN 46074CC.01 03/24/21