Loading...
HomeMy WebLinkAboutPlanset - DownerSHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 A0 PROJECT INFO VICINITY MAP PROJECT SITE PROJECT SITE OWNER: CHRISTOPHER DOWNER ADDRESS:12925 HARRISON DR CARMEL, IN 46033 PHONE: 317-371-3191 EMAIL: TITODOWNER@GMAIL.COM APN:291028305013000018 (HAMILTON COUNTY) CONSTRUCTION TYPE:VB OCCUPANCY TYPE:R3- RESIDENTIAL SHEET INDEX A1 SITE PLAN, PROJECT INFO A2 MOUNTING ROOF PLAN E1 SINGLE LINE DIAGRAM E2 ELECTRICAL CALCULATIONS E3 REQUIRED SIGNAGE E4 MODULE DATA SHEET E5 OPTIMIZER DATA SHEET E6 INVERTER DATA SHEET S1 STANCHION DATA SHEET S2 RACKING DATA SHEET S3 RACKING ENGINEERING S4 RACKING GROUNDING S5 RACKING CERTIFICATION 13.135 DC kW SOLAR PV STRING INVERTER SYSTEM - ROOF MOUNT DOWNER RESIDENCE VICINITY MAP AERIAL VIEW 12925 HARRISON DR CARMEL, IN 46033 ARRAY AREA: 18.82 SQFT x 37 = 696.32 SQFT PROJECT SCOPE INSTALLATION OF ROOF MOUNT SOLAR PV SYSTEM DERATE 200AMP MAIN BREAKER TO 175AMP NEW EQUIPMENT: 37 REC355AA BLK REC SOLAR MODULES 37 P370 SOLAREDGE OPTIMIZERS 1 SE10000H-US (240V) SOLAREDGE HD INVERTER SYSTEM SIZE: 13.135 DC kW RATING 12.315 CEC AC RATING SERVICE: EXISTING 200A MAIN SERVICE PANEL APPLICABLE CODES 2014 IN BUILDING CODES 2020 IN RESIDENTIAL CODES 2012 IN PLUMBING CODES 2014 IN MECHANICAL CODES 2011 NEC (NFPA 70) 2012 INTERNATIONAL FIRE CODE SOLAR PHOTOVOLTAIC SYSTEM NOTES · ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER’S INSTRUCINSTRUCTIONS, NEC 110.2, 110.3, 690.4(B) AND 690.12(5). · ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. · ALL PV CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES, NEC 690.9(A). · ALL EQUIPMENT OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN INITIATION) SHALL BE LOCATED NEAR THE MAINELECTRICAL SERVICE EQUIPMENT, NEC 690.13, 690.15. · RAPID SHUTDOWN EQUIPMENT TO PROVIDE CONTROLLED CONDUCTORS THAT ARE MORE THAN 5 FEET IN LENGTH INSIDE A BUILDING OR MORE THAN 10 FEET FROM A PV ARRAY LIMITATION TO NOT MORE THAN 30 VOLTS AND 240 VOLT-AMPERES WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION, NEC 690.12. · THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTEDELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED, NEC 690.61 & 705.40. · DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER EXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH OPAQUE COVERING,NEC 690.18. · ALL CONDUCTOR EXPOSED TO WEATHER SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT, NEC310.10(D) AND 690.31(C) THROUGH (G). · ALL CONDUCTORS TO BE OF MATERIAL APPROVED BY THE CODE AND THEIR INSULATIONS TO BE RATED TO NOT LESS THAN 90OC 600-VOLTS MINIMUM · INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR GROUNDED DC SYSTEMS,NEC 690.31(B); AND PV-WIRE TYPE FOR UNGROUNDED DC SYSTEMS, (AS IN TRANSFORMERLESS INVERTERS OR MICROINVERTERS WITH ISOLATED GROUNDS), NEC 690.35(D). · FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS AND TERMINALS LISTED AND MARKED FOR THE USE, NEC 110.14 & 690.74(A). · ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END FOR UNIQUE IDENTIFICATION, NEC 690.31(B). · ALL GROUNDED, (NEUTRAL), CONDUCTORS’ INSULATION SHALL BE SOLID WHITE, GRAY, OR WITH 3-WHITE STRIPES, NEC 200.6, 200.7, & 400.22; AND ALL GROUNDING CONDUCTORS SHALL BE OF BARE WIRE WITHOUT COVERING, OR WITH INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, NEC 250.119 & 400.23. THE COLOR OF UNGROUNDED CONDUCTORS SHALL BE OTHER THAN FOR GROUNDED, (NEUTRAL) · MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND OVERCURRENT PROTECTION IS 10 FEET, NEC 705.31 · CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT ANY DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL MEET THE FOLLOWING, NEC 705.12(D). · DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, OR CABLE SHEATHINGS, NEC 690.31(G) · RACEWAYS IN ENCLOSED PORTIONS OF THE BUILDING MUST RUN ALONG BOTTOM OF LOAD BEARING MEMBERS, · METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE SHEATHS CONTAINING CIRCUITS OVER 250-VOLTS TO GROUND MUST BE BONDED IN ACCORDANCE WITH NEC 250.97 & 290.92(B). · FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR THAT ARE IDENTIFIED AND LISTED FOR SUCH USE, NEC 690.31(H) & 110.14. · CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30 VOLTS SHALL REQUIRE TOOL TO OPEN ANDMARKED “DO NOT DISCONNECT UNDER LOAD” OR “NOT FOR CURRENT INTERRUPTING”, NEC 690.33(C) & (E)(2). · EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6 AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR, NEC 690.46 & 250.120(C). · THE INTERCONNECTION POINT SHALL BE ON THE LINE SIDE OF ALL GROUND-FAULT PROTECTION EQUIPMENT, NEC 705.32. · DC PV SOURCE OR DC PV OUTPUT CIRCUITS SHALL BE CONTAINED IN METAL RACEWAYS, TYPE MC CABLE OR METALLIC ENCLOSURES WHEN INSIDE THE BUILDING, NEC 690.31(G). · CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT LOCATED UNDER THE MODULES, MUST BE PROTECTED, NEC 300.4. · PROPOSED LOCATIONS OF ELECTRICAL SERVICE REPLACEMENTS MUST ALSO BE APPROVED BYTHE ELECTRICAL UTILITY COMPANY. · FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPES OF NATURAL GAS, HOT WATER, AND COLD WATER MUST BE PROVIDED, NEC 250.104. · GROUNDING ROD ELECTRODES SHALL BE INSTALLED 8’ MINIMUM IN CONTACT WITH SOIL, NEC 250.53(G). · ALL EXTERIOR CONDUITS SHALL BE PAINTED TO MATCH THE COLOR OF THE SURROUNDING AREA (ROOF, SIDING, AND STUCCO). · EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, & VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED OR BLOCKED BY THE SOLAR PHOTOVOLTAIC SYSTEM. · EXISTING DWV PLUMBING VENT TERMINATIONS THAT ARE HORIZONTALLY LOCATED CLOSER THAN 12” FROM THE PROPOSED MODULES, MUST BE REROUTED, OR MUST BE EXTENDED A MINIMUM OF 6” ABOVE THE SURFACE OF THE MODULES · EXISTING B-VENT TERMINATIONS, FOR FUEL BURNING APPLIANCES, WHERE ADJACENT TO THE PROPOSED MODULES, MUST BE EXTENDED 12” ABOVE THE MODULES’ TOP SURFACE · THE MARKINGS, “WARNING: PHOTOVOLTAIC POWER SOURCE”, FOR DC RACEWAYS AND CABLE ASSEMBLIES MUST BE AT 10’ O.C.; AND BENDS, ABOVE OR BELOW PENETRATIONS OF ROOFS, CEILINGS, WALLS, OR BARRIERS, NEC 690.31(G)(4). · PV COMBINER PANELBOARDS MUST HAVE PERMANENT MARKINGS INDICATING THAT THEY ARE DEDICATED FOR PV CIRCUITS ONLY NO LOADS ARE TO BE CONNECTED. · WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTING ELECTRICAL EQUIPMENT, NEC 110.26. · RESIDENTIAL TYPE PV CIRCUITS OVER 150-VOLTS TO GROUND MUST NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED, NEC 690.7(D). · A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH CAL-OSHA REGULATIONS. · ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BE INSTALLED ON ALL EQUIPMENT PRIOR TO ANY INSPECTIONS. · LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 3/8’’ IN WHITE ON A RED BACKGROUND. · WHEN THE MAIN CIRCUIT BREAKER IS DERATED, A PERMANENT MARKING MUST BE PROVIDED ON THE PANELBOARD TO INDICATE THAT THE MAIN CIRCUIT BREAKER HAS BEEN DOWNSIZED TO_______AMPS, DO NOT UPSIZE IT. · GROUND-MOUNTED PV SYSTEMS MUST HAVE A CLEAR, BRUSH-FREE AREA OF 10-FEET AND A FIRE SEPARATION DISTANCE OF 5-FEET MINIMUM TO OTHER STRUCTURES AND PROPERTY LINES GENERAL NOTES 1. WORKING CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT SHALL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. 2. PV EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL ONLY BE INSTALLED BY QUALIFIED PERSONS. CEC 690.4 (E) 3. ROOFTOP MOUNTED PV SYSTEM PANELS AND MODULES SHALL MEET A MINIMUM FIRE CLASSIFICATION AS REQUIRED BY R902.4 AND CBC 1505.9. 4. ROOF ACCESS POINTS. ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS (R331.4.1).LADDERS SHALL BE OSHA APPROVED AND SECURED TO THE STRUCTURE FOR INSPECTION PURPOSES.CONTRACTORS ARE REQUIRED TO BE PRESENT FOR THE FIRST AND/OR FINAL INSPECTIONS. 5. APPROVED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED WITHIN THE DWELLING UNIT AND SHALL BE FIELD VERIFIED EITHER THROUGH FINAL BUILDING INSPECTION. SMOKE ALARMS ARE REQUIRED TO BE INSTALLED IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. R314.1, R315.1 6. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. 04/02/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 A1 SITE PLAN LEGEND: (E) - EXISTING (N) - NEW SITE PLAN SCALE: 1/16" = 1' (E) 1 - STORY 4075 SQFT N S EW H A R R I SO N D R (E) DRIVEWAY INSIDE HOUSE (E) 200A MAIN SERVICE PANEL (N) SE10000H-US (240V) SOLAREDGE HD INVERTER (N) 60A AC DISCONNECT (N) 37 - REC355AA BLK REC SOLAR MODULES WITH P370 SOLAREDGE OPTIMIZERS P R O P E R TY LI N E (E) UTILITY METER P R O P E R T Y L I N E PROPERTY LINE04/02/21 MSPMIN V D JB 3'18"3'4'3'3' 3'±41116"2.5"MIN2.5"MIN±4916"A2 MOUNTING PLAN SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 MOUNTING PLAN SCALE: 3/32" = 1'-0" LEGEND (E) EXISTING (N) NEW CONDUIT RUN VIF VERIFY IN FIELD JUNCTION BOX MAIN SERVICE PANEL SUBPANEL INVERTER UTILITY METER AC DISCONNECT MSP JB N S EW SUB INV 66 TOTAL ATTACHMENTS @ 4FT OC MAX D M ROOF INFO COMP SHINGLE ROOF 1 - LAYER 2 X 6 RAFTERS 16 " ON CENTER 72 "ATTACHMENT MAX SPACING ON CENTER MODULES COVER 28% OF THE ROOF AREA LESS THAN 33% (CRC 324.6.2) 3/4" EMT CONDUIT RUN WIRING/CONDUIT RUN 7/8'' MINIMUM ABOVE THE ROOF FIRE ACCESS POINT (NOT TO BE OVER ANY DOORS, WINDOWS OR OTHER OBSTRUCTIONS) STRING A OF 13 MODULES STRING B OF 12 MODULES STRING C OF 12 MODULES 3' FIRE PATHWAY PER R324.6.1 (N) 37 - REC355AA BLK REC SOLAR MODULES WITH P370 SOLAREDGE OPTIMIZERS 125.96° AZIMUTH 33° SLOPE A FIRE SETBACK SOLAR PANEL DEAD WEIGHT CALCULATION RACKING MANUFACTURER IRONRIDGE FLUSH MOUNT AND XR100 RAILS MODULE REC ALPHA SERIES MODULE TOTAL # OF MODULES 37 MOUNTING SYSTEM WEIGHT 203.38 LBS MODULE WEIGHT 48.5 LBS TOTAL SOLAR MODULE WEIGHT 1794.50 LBS MODULE LENGTH 67.75 INCHES TOTAL PANEL WEIGHT CALCULATION 1997.88 LBS MODULE WIDTH 40.00 INCHES POINT LOAD CALCULATION 30.27 LBS MODULE AREA 18.82 SQFT TOTAL SOLAR MODULE AREA 696.32 LBS TOTAL# OF ATTACHMENTS 66 DISTRIBUTED LOAD CALCULATION THE POINT LOADING AND DISTRIBUTED LOADING SHOULD BE MAX 5 LBS/FT2 2.87 PSF RACKING WEIGHT .68 LBS / LN FT ROOF COVERAGE TOTAL MODULE AREA 696.32 27.9% </= 50% = OK ROOF FACE AREA 2492 ROOF COVERAGE (%) 27.9 INSIDE HOUSE (E) 200A MAIN SERVICE PANEL (N) SE10000H-US (240V) SOLAREDGE HD INVERTER (N) 60A AC DISCONNECT (E) UTILITY METER 3' FIRE PATHWAY PER R324.6.1 215.68° AZIMUTH 33° SLOPE FIRE SETBACKFI R E SE T B A C K FI R E SE T BA C K FIRE SETBACKA A A A A A A A A A A A B B B B B B B B B B B B C C C C C C C C C C C C MODULE FLASHFOOT IRONRIDGE XR100 RAILS ALUMINUM FLASHING WITH 3-COURSE APPLICATION EXISTING RAFTERS ROOF ATTACHMENT DETAIL SCALE: 1-1/2" = 1'-0" FRONT VIEW SIDE VIEW EXISTING RAFTERS MODULE FLASHFOOT IRONRIDGE XR100 RAILS ALUMINUM FLASHING WITH 3-COURSE APPLICATION 5/16" Ø SS LAG BOLT 1 LAG PER ATTACHMENT 2.5" MIN EMBEDMENT 5/16" Ø SS LAG BOLT 1 LAG PER ATTACHMENT 2.5" MIN EMBEDMENT NOTE: MODULES WILL BE INSTALLED FLUSHED TO EXISTING ROOF SLOPE 04/02/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAGcadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 E1 ELECTRICAL LINE DIAGRAM SERVICE LOAD CALCULATIONS @ MSP BACKFED 120% RULE - PER 705.12 (D) BUS RATING SIZE MUTIPLIER (120%) RESULT 200 1.20 240.00 MCB INVERTER AC OUTPUT +125%RESULT 175 52.50 227.50 240A >/= 227.50A = OK 125% OF TOTAL INVERTER MAX AC OUTPUT MAX AC OUTPUT (AMPS) 125%RESULT (AMPS)OCPD SIZE 42 1.25 40.00 60A WIRE/CONDUIT SCHEDULE TAG DESCRIPTION CONDUCTOR TYPE/SIZE/QUANTITY CONDUIT SIZE/TYPE A ARRAY TO JUNCTION BOX (6) #10 AWG PV WIRE & #6 AWG SOLID COPPER (G) FREE AIR B JBOX TO INVERTER (6) #10 AWG THWN-2 (3+& 3-) & (1) #8 AWG THWN-2 (G) 3/4" EMT C INVERTER TO AC DISCONNECT (3) # 6 AWG THWN-2 (L1, L2 & N) & (1) #8 AWG THWN-2 (G) 3/4" EMT D AC DISCONNECT TO MAIN SERVICE PANEL (3) # 6 AWG THWN-2 (L1, L2 & N) & (1) #8 AWG THWN-2 (G) 3/4" EMT INVERTER SPECIFICATION INVERTER MAKE SOLAREDGE INVERTER MODEL NO. SE10000H-US (240V) MAX INPUT VOLTAGE 480 V MAX INPUT CURRENT 27 A NOMIMAL AC VOLTAGE 240 V MAX AC CURRENT 42A (N)JB BNEMA 3R DC AC... A WITH INTEGRATED DC DISCONNECT AND AUTOMATIC RAPID SHUTDOWN UPON AC GRID DISCONNECT (N) 37 - REC355AA BLK REC SOLAR MODULES WITH P370 SOLAREDGE OPTIMIZERS 13 12 DC/DC CONVERTER/OPTIMIZER VOLTAGE CALCULATION LARGEST MODULE VOC FOR SINGLE-MODULE DC/DC CONVERTER CONFIGURATIONS (WITH 80V AFCI CAP) (CEC 690.7 and 690.11) MODULE VOC ____ X # OF MODULES PER CONVERTER ___X CF = V MODULE VOC MODULES PER INVERTER TL IS GREATER THAN OR EQUAL TO -5°C, CF VOLTS 43.60 1.00 1.12 48.83 60V > 48.83V = OK THE VALUE CALCULATED MUST BE LESS THAN OPTIMIZERS MAX DC INPUT VOLTAGE (N) SE10000H-US (240V) SOLAREDGE HD INVERTER MAX AC OUTPUT = 42A NEC 705.12(D)(2)(3)(B) WHERE TWO SOURCES, ONE A UTILITY AND THE OTHER AN INVERTER, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125% OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120% OF THE AMPACITY OF THE BUSBAR. PV BREAKER MUST BE INSTALLED AT THE FARTHEST OPPOSITE END OF THE MAIN BREAKER MODULE SPECIFICATION MANUFACTURER REC SOLAR MODEL NO. REC355AA BLK PEAK POWER 355W RATED VOLTAGE (Vmp) 36.4 V RATED CURRENT (Imp) 9.77 A OPEN CIRCUIT VOLTAGE (Voc) 43.6 V SHORT CIRCUIT CURRENT (Isc) 10.47 A (N)175A MCB DERATE M (N)60A (E) 200A MAIN SERVICE PANEL G N EXISTING WIRES & CONDUCTORS (E) UTILITY METER PV OCPD (N) 60A AC DISCONNECT D SOLAR GROUND TYING INTO THE EXISTING UFER GROUND POINT C INSIDE HOUSE (E) EARTH GROUND 12 INVERTER DC INPUT CURRENT IS REGULATED BY SOLAREDGE OPTIMIZER, MAX STRING CURRENT IS 4615= 11.54 AMPS400 INVERTER DC INPUT VOLTAGE IS REGULATED BY SOLAREDGE OPTIMIZER MAX # OF MODULES IN A STRING X MODULE WATTAGE NOMIMAL DC INPUT VOLTAGE OF INVERTER 11.54 AMPS </= 15 AMPS = OK 13 X 355 W 400 V = WITH A MAXIMUM SHORT CIRCUIT OF 15A (OPTIMIZER MAX OUTPUT CURRENT) [CEC 690.8] 04/02/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 E2 ELECTRICAL CALCULATIONS DC CONDUCTOR AMPACITY CALCULATIONS ARRAY TO JUNCTION BOX (CEC ART 310.15) A EXPECTED WIRE TEMPERATURE (FREE AIR) 35 CELSIUS B ADD 22°C OR 4O°F FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOF 57 CELSIUS TEMPERATURE CORRECTION FACTOR CEC TABLE 310.15 (B)(2)(A)0.71 C # OF CURRENT CARRYING CONDUCTORS 6 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) D CONDUIT FILL CORRECTION 0.80 .80 (FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00 (FOR 3 OR LESS CONDUCTORS IN CONDUIT) CEC TABLE 310.15 (B)(3)(A) E CIRCUIT CONDUCTOR SIZE #10 AWG MINIMUM #10 AWG CU, 90°C WET (USE-2, PV WIRE, THWN-2, RHW-2) F CIRCUIT CONDUCTOR AMPACITY 40 AMPS CEC TABLE 310.15 (B)(16) G REQUIRED CIRCUIT CONDUCTOR AMPACITY 18 AMPS OPTIMIZER ISC H DERATED AMPACITY OF CIRCUIT CONDUCTOR 22.72 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY CEC TABLE 310.15 (B)(2)(A) NOTE: "H" MUST BE LARGER THAN "G" 22.72A > 18.00A = OK DC CONDUCTOR AMPACITY CALCULATIONS FROM JUNCTION BOX TO INVERTER A AMBIENT TEMPERATURE ADJUSTMENT EXPOSED CONDUIT 57 CELSIUS (ADD 22° OR 4O° FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOF) CEC TABLE 310.15 (B)(2)(A) & CEC TABLE 310.15 (B)(2)(C) EXPECTED WIRE TEMPERATURE TEMPERATURE CORRECTION FACTOR 0.71 CEC TABLE 310.15 (B)(2)(A) # OF CURRENT CARRYING CONDUCTORS 6 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) CONDUIT FILL CORRECTION 0.80 .80 (FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00 (FOR 3 OR LESS CONDUCTORS IN CONDUIT) CEC TABLE 310.15 (B)(3)(A) CIRCUIT CONDUCTOR SIZE #10 AWG MINIMUM #10 AWG CU, 90°C WET (USE-2, PV WIRE, THWN-2, RHW-2) CIRCUIT CONDUCTOR AMPACITY 40 AMPS CEC TABLE 310.15 (B)(16) B REQUIRED CIRCUIT CONDUCTOR AMPACITY 18 AMPS OPTIMIZER ISC C DERATED AMPACITY OF CIRCUIT CONDUCTOR 22.72 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY CEC TABLE 310.15 (B)(2)(A) NOTE: "C" MUST BE LARGER THAN "B" 22.72A > 18.00A = OK AC CONDUCTOR AMPACITY CALCULATIONS BETWEEN INVERTER TO MAIN SERVICE A AMBIENT TEMPERATURE ADJUSTMENT EXPOSED CONDUIT 57 CELSIUS (ADD 22° OR 4O° FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOF) CEC TABLE 310.15 (B)(2)(A) & CEC TABLE 310.15 (B)(2)(C) EXPECTED WIRE TEMPERATURE TEMPERATURE CORRECTION FACTOR 0.96 CEC TABLE 310.15 (B)(2)(A) # OF CURRENT CARRYING CONDUCTORS 2 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) CONDUIT FILL CORRECTION 1.00 .80 (FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00 (FOR 3 OR LESS CONDUCTORS IN CONDUIT) CEC TABLE 310.15 (B)(3)(A) CIRCUIT CONDUCTOR SIZE #6 AWG MINIMUM #10 AWG CU, 90°C WET (USE-2, PV WIRE, THWN-2, RHW-2) CIRCUIT CONDUCTOR AMPACITY @ 90° 75 AMPS CEC TABLE 310.15 (B)(16) INVERTER'S MAXIMUM AC OUTPUT CURRENT 42 AMPS INVERTER MANUFACTURER SPECIFICATIONS B REQUIRED AC CONDUCTOR AMPACITY 40.00 AMPS REQUIRED AC CONDUCTOR AMPACITY =1.25 X MAXIMUM INVERTER'S OUTPUT CURRENT (AMPS) C DERATED AMPACITY OF CIRCUIT CONDUCTORS 72.00 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY CEC TABLE 310.15 (B)(2)(A) NOTE: "C" MUST BE GREATER THAN "B" 72.00A > 52.50A = OK OPTIMIZERS SPECIFICATION MAKE SOLAREDGE P370 MAXIMUM INPUT DC POWER 370 ABSOLUTE MAX INPUT VOLTAGE (VOC)60 VDC MAX SHORT CIRCUIT CURRENT (ISC)11 ADC MAX DC INPUT CURRENT 13.75 ADC MAX OUTPUT CURRENT 15 ADC MAX OUTPUT VOLTAGE 60 ADC LOCATION INFORMATION HIGH TEMP 35° LOW TEMP -22° VOLTAGE CORRECTION FACTOR 1.12 ROOF TEMP + 22° 57° TEMP CORRECTION FACTOR (EXPOSED) 0.71 TEMP CORRECTION FACTOR (CONDUIT) 0.96 INVERTER SPECIFICATION INVERTER MAKE SOLAREDGE INVERTER MODEL NO. SE10000H-US (240V) MAX INPUT VOLTAGE 480 V MAX INPUT CURRENT 27 A NOMIMAL AC VOLTAGE 240 V MAX AC CURRENT 42A MODULE SPECIFICATION MANUFACTURER REC SOLAR MODEL NO. REC355AA BLK PEAK POWER 355W RATED VOLTAGE (Vmp) 36.4 V RATED CURRENT (Imp) 9.77 A OPEN CIRCUIT VOLTAGE (Voc) 43.6 V SHORT CIRCUIT CURRENT (Isc) 10.47 A 04/02/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 E3 REQUIRED SIGNAGE DIRECTORY PLACARD NEC 705.10 & NEC 690.56(B) REQUIRES A PERMANENT PLAQUE OR DIRECTORY DENOTING ALL ELECTRIC POWER SOURCE ON OR IN THE PREMISES OR RAPID FIRE SHUTDOWN EQUIPMENT; INSTALL AT MAIN SERVICE PANEL · ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES AND DISCONNECTS ARE MARKED. (CFC 605.11.1, CEC 690.31[E], 690.17 & 690.53 & CRC R324) · THE MARKINGS ON THE CONDUITS, RACEWAYS AND CABLE ASSEMBLIES ARE EVERY 10 FEET, WITHIN ONE FOOT OF ALL TURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOW ALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS AND BARRIERS. (CFC 605.11.1.4, CEC 690.31[E]) · MARKING IS PLACED ADJACENT TO THE MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM WHERE THE DISCONNECT IS OPERATED. (CFC 605.11.1.3 & CRC R324) · THE MARKINGS SAY WARNING: PHOTOVOLTAIC POWER SOURCE AND HAVE 3/8-INCH (9.5 MM) MINIMUM-SIZED WHITE LETTERS ON A RED BACKGROUND. THE SIGNS ARE MADE OF REFLECTIVE WEATHER RESISTANT MATERIAL. (CFC 605.11.1.1, 605.11.1.2 & CRC R324 & CEC 690.31) · WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP, LAMINATE OR MEMBRANE ROOFING MATERIALS IN ROOF AREAS NOT COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT, THE LOCATION OF CIRCUITS SHALL BE CLEARLY MARKED. (CEC 690.4) · REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FOR THE ENVIRONMENT. SIGNAGE NOTES:H ARRISON DRDRIVEWAY MAIN SERVICE PANEL INVERTER AC DISCO SOLAR ARRAYS 6"5" UTILITY METER CAUTION POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN G F SIGNS AND LABEL - CENTRAL/STRING INVERTER SYSTEMS NEC ARTICLES 690 AND 705 REQUIRE THE FOLLOWING LABELS OR MARKINGS BE INSTALLED AT THESE COMPONENTS OF THE PHOTOVOLTAIC SYSTEM: WARNING: PHOTOVOLTAIC POWER SOURCE NEC 690.31(G)(3)(4) ON ALL INTERIOR AND EXTERIOR PV CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES AND JUNCTION BOXES PROVIDE A SIGN WITH THE FOLLOWING WORDING: H CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINAL. TERMINAL ON BOTH LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.17 AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THE FOLLOWING WORDING: WARNING INVERTER CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE PER NEC 690.64 AND 705.12(D)(4) EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. LOCATED AT BACKFED BREAKER PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE PER NEC690.35(F) WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL FOR SOLAR AC DISCONNECT: SOLAR AC DISCONNECT PROVIDE WARNING LABEL AT THE UTILITY INTERACTIVE INVERTER OR GROUND FAULT INDICATOR STATING: WARNING ELECTRIC SHOCK HAZARD IF THE GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. PLAQUE TO BE INSTALLED ON FACE OF THE UTILITY AC DISCONNECT: PV SYSTEM DISCONNECT FOR UTILITY OPERATION TO BE INSTALLED ON THE FACE OF THE SERVICE METER PANEL: CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT LOCATED AS SHOWN LABEL FOR SOLAR DC DISCONNECT: SOLAR DC DISCONNECT PLAQUE TO BE INSTALLED AT ELECTRIC SERVICE: PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL FOR SOLAR DC DISCONNECT: OPERATING CURRENT OPERATING VOLTAGE MAXIMUM SYSTEM VOLTAGE MAXIMUM SYSTEM CURRENT MAXIMUM INVERTER OUTPUT 11.54 A 400.00 A 480.00 V 15.00 A 42 A A E B C D I J K L 04/02/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 E4 MODULE DATA SHEET 04/02/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 E5 OPTIMIZER DATA SHEET 04/02/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 E6 INVERTER DATA SHEET 04/02/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 S1 STANCHION DATA SHEET 04/02/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 S2 RACKING DATA SHEET 04/02/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 S3 RACKING ENGINEERING 04/02/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 S3.1 RACKING ENGINEERING 04/02/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 S3.2 RACKING ENGINEERING 04/02/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 GROUNDING DATA SHEET S4 04/02/21 SHEET TITLE SHEET NUMBER REVISION OWNER PROJECT TITLE JOBSITE ADDRESS DOWNER RESIDENCE 12925 HARRISON DR CARMEL, IN 46033 13.135 DC kW 12.315 kW CEC-AC Rating STRING INVERTER SYSTEM DATE DESCRIPTION DATE DRAWN02-18-21 DESIGN REVISION DESIGN BY: CONTRACTOR SIGNATURE OF LICENSE HOLDER LG/SC SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 CAD FOR CALI I NC. 3911 N. COLLEGE AVE, SUITE B. INDIANAPOLIS, IN 46205 PHONE: 855.573.2843 RACKING CERTIFICATION S5 04/02/21