Loading...
HomeMy WebLinkAboutA114 Fourth Floor PlanDN DN GENERAL NOTES 1. ALL CEILING ARE TO BE 10'-0" A.F.F. UNLESS NOTED OTHERWISE. 2. ALL UNITS ARE DESIGNED AS A117.1 ANSI TYPE B UNITS. ALL UNITS ARE TO COMPLY WITH THE ACCESSIBILITY CODES LISTED ON THE COVER SHEET. 3. SEE MECHANICAL DRAWINGS FOR IN-WALL WATER CONNECTIONS 4. CONTRACTOR TO VERIFY SIZE AND FRAMING DIMENSIONS OF HVAC UNIT, BATHTUB DOORS AND WINDOWS. 5. PROVIDE 1x2 PTD WOOD TRIM @ INTERIOR OF ALL CLOSETS / UTILITY CLOSETS WHERE STANDARD DOOR CASING WILL NOT FIT. 6. UNDERCUT ALL INTERIOR DOORS FOR RETURN AIR 1". 7. BASE OF MIRROR REFLECTED SURFACE TO BE INSTALLED 40" AFF MAXIMUM. 8. PROVIDE ELECTRICAL OUTLET IN KITCHEN ISLAND SIDEWALL 6" BELOW COUNTERTOP AT CENTERLINE OF WALL. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION. 9. ALL WALLS / WALL SECTIONS BEHIND PLUMBING FIXTURES TO BE 2X6 MINIMUM. - FINISH WALLS TO ALIGN. 10. ALL SLOPED CONCRETE SURFACES ARE TO RECEIVE BROOM FINISH. 11. ALL PENETRATIONS THROUGH RATED ASSEMBLIES ARE TO BE PROTECTED AS PER APPLICABLE UL SYSTEM LISTING. PLAN NOTES FIRE EXINGUISHER IN SEMI-RECESSED CABINET -REFERENCE LIFE SAFETY PLANS FOR LOCATIONS. SEE 18/A400 FOR DETAILS. 48"x48" MIN. ROOF ACCESS HATCH. HATCH AREA REPRESENTS CEILING TO BE 8'-6" A.F.F. RAMP SLAB UP 8", PROVIDE HANDRAILS BOTH SIDES -EXTEND HANDRAILS 1'-0" PAST END OF RAMP. TENANT MAILBOXES: SEE SPECS. TRUSS TOP PLATE SHALL BE -4" AT THIS SHOWER LOCATION, SEE STRUCTURAL. 1 2 3 4 5 6 A212 A212 A211 1 2 1 A2112 71' - 4"36' - 4"17' - 0"2' - 0"14' - 0"2' - 0"7' - 10"10' - 9 1/2"13' - 10"3' - 10 1/2"9' - 1"7' - 11"70' - 4" 3' - 6" 5' - 11 1/2"19' - 8"11' - 10 1/2"10' - 0 3/8"6' - 9"12' - 6 5/8"36' - 4"17' - 0"2' - 0"14' - 0"2' - 0"71' - 4"14' - 7 1/4"13' - 1"8' - 7 3/4"9' - 1"70' - 4" 16' - 0 1/2"38' - 3"16' - 0 1/2" 8' - 6 1/2"7' - 6"7' - 5 1/2"23' - 4"7' - 5 1/2"7' - 6"8' - 6 1/2" ELEVATOR LOBBY 402 ST1-4 ST1-4 ELEVATOR ELV-1 ST2-4 ST2-4 TENANT PH OPEN ROOF PATIO OUTDOOR LIVING DINING GREAT ROOM STUDY FIREPLACEKITCHEN CLOSET BATHROOM PANTRY BATHROOM CLO.BEDROOM CORRIDOR BEDROOM CLOSET CLOSET BATHRM. CLO. MASTER BATH HVAC LAUNDRY MASTER BEDROOM MASTER PATIO 3 A131 3 A132 6 A132 14' - 5"3 1/2"6' - 10"3 1/2"6' - 5"3 1/2"6' - 10 1/2"13' - 3 1/2" 3 1/2" 7' - 3 1/2" 3 1/2" 5' - 0" 3 1/2" 7' - 2" 3 1/2" 12' - 7 1/2"3 1/2"14' - 3"3 1/2" 8' - 0 1/2" 8' - 1" 3 1/2" 7' - 2 1/2" 3 1/2" 4' - 2"3 1/2" 10' - 3 1/2" 13' - 3 1/2" 3 1/2" 4' - 1 1/2" 3 1/2" 3' - 8" 3 1/2" 7' - 2 1/2" 3 1/2" 4' - 2" 3 1/2" 12' - 7 1/2" 3 1/2" 3' - 8" 3 1/2" 10' - 3 1/2" 3 1/2" 8' - 0 1/2" 29' - 2"11' - 1"3' - 6 1/2" 3 1/2" 5' - 3 1/2" 3 1/2" 3' - 8" 5 1/2" 6' - 6" 3 1/2" 8' - 10" 2' - 5 1/2" 3' - 6 1/2" 3 1/2" 5' - 5 1/2" 3 1/2" 3' - 6" 5 1/2" 3' - 11 3/8" 3 1/2" 2' - 3 1/8" 3 1/2" 8' - 10" 13' - 1 1/2"11' - 1"13' - 1 1/2"5' - 11 1/2"3 1/2"6' - 0"3 1/2"1' - 10 1/2"3 1/2"5' - 11 1/2"3 1/2"1' - 10 1/2"3 1/2"6' - 0"3 1/2"3' - 6"5' - 11 1/2"5 1/2"5' - 4"3 1/2"6"1' - 10 1/2"14' - 5"3 1/2"3' - 8"3 1/2"1' - 6"5 1/2"9' - 4"3 1/2"24' - 2"12' - 1"3 1/2"5' - 10"5 1/2"3' - 11 1/4"3 1/2"6' - 10 3/4"5 1/2"5' - 2"4' - 4"3 1/2"4' - 3 1/2"3 1/2"1' - 11"3' - 8 1/2"5 1/2"2' - 8 3/4"4' - 11 1/2"3 1/2"13' - 1 1/2"WG1a WG1aWG1aWG1a WG1a WG1a WG1aWG1bWG1aWG3aWG1a WG1aL K C C C C DC CC CH C CCDCAST1-4 WG3a WG1aWG1a WG1aWG1a WG3bWG3a WG1bWG1a WG1a WG1a WG1bWG3aWG3aWG1b WG1aWG1a WG1bWG1a WG1aW4 W4 W9 W6 W12 W10 W10 W14L W4 W6 W5LW5R W16 W14R W14L W14R CF D UTILITY CLO.WG3aWG3aWG3a 7' - 1 1/2"8' - 8 3/4" W8 6 WG1b2' - 8"WG3aWG3a 3 W161/4"/12"1/4"/12"1/4"/12"1/4"/12" 1/4"/12"1/4"/12"1/4"/12"1/4"/12"1/4"/12"1/4"/12"1/4"/12"1/4"/12"WOOD DECK (B2)SYNTHETICGRASS (B3)WOOD DECK (B2)SYNTHETICGRASS (B3)2 1/4"/12"1/4"/12"1/4"/12"1/4"/12"1 13 1/2" 8' - 3 1/4" 3 1/2" 5 1/2" 2' - 0" 6' - 2 3/4" 1 ARCHITECTCLIENTGC/CMPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS20022 NOVEMBER 11, 2020 100% CONTRACT SET A114FOURTH FLOOR PLANMAGNOLIACONDOMINIUMSCARMEL, INSCALE: 1/4" = 1'-0"1 FOURTH FLOOR PLAN #DESCRIPTION DATE 1 100% CONTRACT SET 11-11-2020 1