HomeMy WebLinkAboutA311 Interior Wall SectionsSECOND FLOOREL: +12'-0"THIRD FLOOREL. 24'-0"PLATE BEARINGEL. 46'-0"FIRST FLOOREL. 0'-0"FOURTH FLOOREL. 36'-0"INTERIOR WALL SECTIONS ARCHITECTCLIENTPROJECTDRAWING TITLESEALSHEETPROJECT INFO REVISIONS20022NOVEMBER 11, 2020#DESCRIPTIONDATEMAGNOLIA CONDOMINIUMS CARMEL, IN100% CONTRACT SETGC/CMA311SCALE:01WALL SECTION1 HOUR DEMISING1/4" = 1'-0"F1 F1 WG5aF2 F2 WG5aF2 F2 WG5aF2 F2 WG5aR1 R1 2A3112A3112A3113A311WG5aF2 PROVIDE FIRE BLOCKINGAT ALL FLOOR LINESPROVIDE FIRE BLOCKINGAT ALL CEILING LINESFLOOR SHEATHING TO BECONTINUOUS ACROSSAIRSPACE AT DEMISINGWALLS AND ACT ASDRAFSTOPPINGCONTINUE WOODSHEATHING INTO FLOORSPACE AND UP TO FLOORSHEATHING ABOVE TOACT AS DRAFTSTOPPINGF2 SCALE:02SECTION DETAIL1 1/2" = 1'-0"PROVIDE FIRE BLOCKINGAT ALL CEILING LINESWOOD SHEATHINGUP TO ROOF SHEATHINGABOVE TO ACT ASDRAFTSTOPPINGR1 R1 SCALE:03SECTION DETAIL1 1/2" = 1'-0"WG5aWG5a4"4"1100% CONTRACT SET 11-11-20201SET RESILIENT CHANNELS ON EA. SIDE OFTHE WALL WITH STUD LEG AS SHOWN ANDMAX. 1.75 INCHES AWAY FROM WALL STUD,THEN CONTINUES INSTALLING THEM PER ULASSEMBLY REQUIREMENTS