HomeMy WebLinkAboutA400 Unit Typical DetailsEXTERIOR SIDEEXTERIOR WALL FINISHJOINT (TAPE AND COMPOUND)THE EXTERIOR WALL FINISH AND THE SHEATHING ARETHE ONLY SOLID WALL OR FLOOR ELEMENTS THATBRIDGE THE SEPARATION BETWEEN DWELLING UNITSCONTINUOUS SEALANTCONTINUOUS SEALANTJOINT (TAPE AND COMPOUND)24" MIN.SEAL DRYWALL TIGHT TO BASE AND FILL GAPS WITHTAPE AND MUD OR NON-HARDENING SEALANTNOTES:1. LIGHT SWITCHES AND OUTLETS SHOULD BE OFFSET AT LEAST 24" AND BELOCATED IN SEPARATE STUD CAVITIES.2. SOUND ATTENUATION INSULATION SHOULD EXTEND BEHIND ELECTRICALOUTLETSSEAL DRYWALL TIGHT TO BOXPENETRATION AND FILL GAPS WITH JOINTCOMPOUND/MUD. USE JOINT REINFORCINGTAPE AS NEEDEDWATER CLOSETFILL THE GAP BETWEEN THE EDGESOF THE FLOOR PENETRATION ANDTHE WATER CLOSET FLANGE WITHAN APPROVED MEMBRANEPENETRATION FIRESTOP SYSTEMWATER CLOSETS TO BE RESILIENTLY MOUNTED WHEN SERVED BY DRAINSOR VENTS WHICH ARE INSTALLED WITHIN DEMISING ASSEMBLIESSECTION VIEWJOINT (TAPE ANDCOMPOUND)AT BOTH SIDES OFWALLSET RESILIENT CHANNELS ON EA.SIDE OF THE WALL WITH STUDLEG AS SHOWN AND MAX. 1.75INCHES AWAY FROM WALL STUD,THEN CONTINUE INSTALLING THEMPER UL ASSEMBLYREQUIREMENTSUNIT SIDEUNIT SIDENON- HARDENING SEALANTCONTINUOUS SEALANTCONTINUOUS SEALANTPROVIDE FIRE BLOCKING ATALL CEILING LINESSEE 2/A311 FOR ADDITIONAL INFORMATIONPROVIDE PERIMETER ISOLATION FOAM STRIP @ALL UNIT WALL TO FLOOR INTERSECTIONS.CONTINUE TO FACE OF SILL PLATESECTION VIEWSHEATHING PER STRUCTURAL DWGSSOUND ISOLATION MATCEMETITIOUS UNDERLAYMENTSCHEDULED FLOORINGGAP UNDER BASE BOARDSCHEDULED BASE BOARD SHALL NOTCONTACT FLOORING. DO NOT APPLY SEALANTBETWEEN BASE AND FLOORINGSCHEDULED WALL, REF. ENLARGED UNIT PLANSCONTINUOUS SEALANTTOP OF COUNTER3'-0" A.F.F.REF. FLOOR PLANS FORWALL TYPESWRAP BOX (5 SIDES) WITH 58"TYPE 'X' GWB, TAPE ALLJOINTSSEMI-RECESSED FIREEXTINGUISHER CABINET2 x WIDTH OF WALL FIREBLOCKING, TYP.FLEXIBLE FLASHING (ONEXTERIOR SHEATHING)TOP STRAIGHT FLASHINGOVER VERTICAL STRAIGHTFLASHINGWALL PENETRATION.SEAL CONTINUOUS AROUND ITAND FINAL EXT. WALL FINISHVERT. STRAIGHT FLASHINGOVER HRZ. BOTTOMSTRAIGHT FLASHINGREFER TO LIGHTINGSCHEDULE FORACTUAL DESIGNCAULK ELECTRICALBOXES TO DRYWALLNOTE:1. LIMIT INSTALLATION OFRECESSED CANS TO FURREDDOWN LOCATIONS AT UNITSEPARATIONS TO AVOIDCOMPROMISINGFIRE AND SOUND RATINGS.SEAL BATHROOM DRAINPENETRATIONFIRE-RETARDENTSEALANT,ENTIRE PERIMETER OFCOLLARNON-COMBUSTABLE FLUECOLLAR (SHEET METAL)HVAC UNITPROVIDE SEALANT (FIRE-RETARDANTAT RATED CONSTRUCTION) ATPERIMETER OF COLLAR BEHIND ALLREGISTER/RETURN AIR BOOTS,TYPICAL.HVAC DUCTGRILL COVER - SEE MECHDRAWINGSUNIT TYPICAL
DETAILSA400SCALE:01AT INTERIOR WALLSTUB/SHOWER1 1/2" = 1'-0"58" TYPE 'X' GYPSUM WALL BOARDSHALL EXTEND TO FLOOR LEVEL.SCALE:07AT DEMISING ASSEMBLYELECTRICAL PENETRATION1 1/2" = 1'-0"SCALE:08AT DEMISING ASSEMBLYPLUMBING PENETRATION1 1/2" = 1'-0"SCALE:03AT DEMISING FLOOR ASSEMBLYPLUMBING PENETRATION1 1/2" = 1'-0"SCALE:09AND EXTERIOR WALLINTERSECTION UNIT DEMISING WALL1 1/2" = 1'-0"SCALE:10ATTACHMENT TO CEILING AND FLOOR DEMISING WALL1 1/2" = 1'-0"SCALE:04FLOOR TO WALL CONNECTIONTYPICAL VINYL PLANK3" = 1'-0"BATHTUB / SHOWER SURROUNDSCALE:02SECTION DETAILKITCHEN ISLAND1 1/2" = 1'-0"SCHEDULED UNITKITCHEN COUNTERTOPPAINT GRADEWOOD TRIMSCHEDULED UNITBASE BOARDUNIT CASEWORK PERUNIT INTERIOR ELEVATIONSAND UNIT ENLARGEDFLOOR PLANSSCALE:05DETAILFIRE EXTINGUISHER1 1/2" = 1'-0"WG1b12"ARCHITECTCLIENTPROJECTDRAWING TITLESEALSHEETPROJECT INFO REVISIONS20022NOVEMBER 11, 2020#DESCRIPTIONDATEMAGNOLIA
CONDOMINIUMS
CARMEL, IN100% CONTRACT SETGC/CM58" GYPSUM GREEN BOARD TO STOPAT TOP OF TUB OR SHOWER PAN. USE12" CEMENT BACKERBOARD IN LIEU OFGYPSUM GREEN BOARD AT TILEDSHOWERS.1100% CONTRACT SET 11-11-20201SCALE:06PENETRATION DETAILTYPICAL SEALANT @1 1/2" = 1'-0"SCALE:11BOX SEALING DETAILLIGHT FIXTURE ELECTRICAL1 1/2" = 1'-0"SCALE:12PENETRATION (TUB)BATHROOM DRAIN1 1/2" = 1'-0"SCALE:13PENETRATION SEALING DETAILHVAC RATED1 1/2" = 1'-0"SCALE:14PENETRATION SEALING DETAILHVAC RATED1 1/2" = 1'-0"