HomeMy WebLinkAboutA001 First Floor Code PlanCODE PLAN GRAPHICS LEGEND
NON-RATED ASSEMBLY
1 HR RATED ASSEMBLY
2 HR RATED ASSEMBLY
DRAFT STOP LOCATION
FIRE EXSTINGUISHER CABINET
DIRECTION OF TRAVEL
DEMISING WALL
31 0
0"
EXIT
OCCUPANT LOAD
THROUGH EXIT
EGRESS WIDTH
ALLOWABLE NUMBER
OF OCCUPANTS
THROUGH EXIT
LOAD FACTOR KEY
R -RESIDENTIAL -200 GROSS
U -UTILITY -200 GROSS
S -STORAGE -300 GROSS
STAIR WIDTH = X
DOOR WIDTH = X
xxx
STAIR WIDTH FACTOR
0.20" PER OCCUPANT
DOOR WIDTH FACTOR
0.15" PER OCCUPANT
EGRESS CAPACITY OF
STAIR
R-2 210SF
ROOM
#
1202 1
OCCUPANCY
GROUP
ROOM IDENTIFICATION
ROOM AREA
NUMBER OF EXITS
REQUIRED
OCCUPANT LOAD
FACTOR
NUMBER OF
OCCUPANTS
FEC
1. SEE COVER SHEET FOR APPLICABLE BUILDING CODES,
OCCUPANCIES, AND CONSTRUCTION TYPES.
2. SEE A020 SERIES FOR SPECIFIC FLOOR, ROOF, AND WALL
ASSEMBLY RATINGS AND CONSTRUCTION.
3.SEE A030 SERIES FOR UL ASSEMBLY DESIGNATIONS AND
CONSTRUCTION.
4. ALL DEMISING WALLS BETWEEN ADJACENT UNITS AND
BETWEEN UNITS & CORRIDORS TO BE 1 HOUR RATED.
6.ALL STAIR AND ELEVATORS SHAFTS TO BE 2 HOUR RATED.
7.SEE INTERIOR WALL SECTIONS ON SHEET A311 FOR DETAILS
AT 1 HOUR RATED ASSEMBLIES.
GENERAL CODE NOTES
1.UNIT DEMISING WALL BETWEEN UNITS TO BE 1-HOUR FIRE
WALL. SEE WALL TYPE WG5.
2.SHAFTLINER TO EXTEND TO FACE OF EXTERIOR
SHEATHING. SEE DETAILS X ON SHEET AXXX.
3. PROVIDE 4'-0" MINIMUM FIRE RETARDENT ROOF
SHEATHING ON BOTH SIDES OF FIRE WALL. SEE DETAILS
ON A311.
CODE PLAN NOTES#
FIRST FLOOR:46
SECOND FLOOR:20
THIRD FLOOR: 20
FOUTH FLOOR:15
TOTAL:101
TOTAL OCCUPANTS
F.E.C.
80SF
1
S-2
RISER ROOM
105
300 1
679SF
4
U
GARAGE
3B
200 2
522SF
3
U
GARAGE
2B
200 2
562SF
3
U
GARAGE
3A
200 2 527SF
3
U
GARAGE
2A
200 2
659SF
4
U
GARAGE
PH
200 2
525SF
3
R2
ENTRY LOBBY
101
200 1
453
68"
227
34"
46
7
DOOR WIDTH = 34"
153
STAIR WIDTH = 46"
DOOR WIDTH = 34"
140
STAIR WIDTH = 42"
20
MAXIMUM TRAVEL DISTANCE = 56'-8"28SF
1
S-2
UTILITY
106
300 1
61SF
1
S-2
STORAGE
PH
300 1
81SF
1
S-2
STORAGE
3B
300 1
81SF
1
S-2
STORAGE
3A
300 1
81SF
1
S-2
STORAGE
2B
300 1
112SF
1
S-2
STORAGE
2A
300 1
6
1
1
1 ARCHITECTCLIENTGC/CMPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS20022
NOVEMBER 11, 2020
100% CONTRACT SET
A001FIRST FLOOR CODEPLANMAGNOLIACONDOMINIUMSCARMEL, INSCALE: 1/4" = 1'-0"1 FIRST FLOOR CODE PLAN
#DESCRIPTION DATE
1 100% CONTRACT SET 11-11-2020
1