HomeMy WebLinkAboutE111 Overall First Floor Electrical Plan)RDINATE DUPLEXES
)NE LINES, CABLE LINES
,H OWNER
BATE UNIT HEATER
TECT WITH M.C.
OVERALL FIRST FLOOR ELECTRICAL PLAN
SCALE: 1/4" = 1' - 0"
ELECTRICAL SYMBOL KEY
SWITCH
4
3-WAY OR 4-WAY SWITCH
�GFI
GROUND FAULT INTERRUPTER (GFI)
220 VOLT OUTLET
120 VOLT OUTLET; IN UNITS/GUEST: ARC FAULT CIRCUIT
INTERUPTER OUTLET OR CONNECTED TO AFCI BREAKER
=11!�_
HALF -SWITCHED OUTLET
=&WP
WEATHER PROOF OUTLET
�p
DEDICATEDDMEDCADTEDLEX SINGLE C RECP. FOR MICRO
O
FAN RATED CEILING BOX W/ WHITE COVER
TV AND DATA = (1)RG-6 COAX (1)CAT5E
A
TV AND DATA = (1)RG-6 COAX (2)CAT5E
EDP
UNIT ELECTRICAL PANEL
O
HARD WIRED SMOKE/CO DETECTOR
t
DISCONNECT
JUNCTION BOX
CO AND NO2 SENSOR
PC
PHOTO -CELL LIGHT/ DAY LIGHT
OC
OCCUPANCY LIGHT/ MOTION LIGHT
n
AUDIBLE FIRE ALARM W/ STROBE ALL COMMON AREAS,
ADA UNITS. AUDIBLE FIRE ALARM ALL OTHER UNITS;
EXIT SIGN
EMERGENCY LIGHT
(>-H
REMOTE HEAD EXTERIOR EMERGENCY LIGHT
BBH
BASEBOARD HEATER 1000W
0
HOUSE PANEL
WALL EXHAUST VENT
EXHAUST VENT
THERMOSTAT
2'X4' LED TROFFERS FIXTURE
LED DRY STRIPLIGHT
SURFACE MOUNTED FIXTURE
®
SURFACE MOUNTED FIXTURE
1-0
WALL MOUNTED FIXTURE
EXIT SIGN W/ EMERGENCY LIGHT
=&F
120 VOLT OUTLET IN FLOOR
=&4
120 VOLT QUAD OUTLET
ELECTRICAL FIXTURE SCHEDULE
TYPE
MFGR & MODEL NUMBER
LAMP TYPE
MOUNTING
DESCRIPTION & USE
A
SEAGULL, 14520S-15
LED
CEILING
UNIT CLOSET, BATH,
LAUNDRY, FOYER
B
SEAGULL, 61160EN3-839
LED
PENDANT
UNIT KITCHEN BAR
C
SEAGULL, 41162-839
LED
WALL
BATHROOM VANITY
D
BROAN 744 VERIFY WITH M.C.
LED
RECESSED
SHOWER LIGHT/VENT
E
CEILING FAN ROYAL STAR 1052BN-ES
LED
CEILING
BEDROOM CEIL FAN
F
SEE MECHANICAL SHEETS
N/A
WALL
EXHAUST FAN
G
SEAGULL, 14520S-15
LED
RECESSED
GREAT ROOM, BEDROOMS,
KITCHEN, CORRIDORS
H
SEAGULL, 14520S-15
LED
RECESSED
OUTDOOR PATIOS AND
LIVING
I
RP LIGHTING BOSQUE 1018W FAN
LED
CEILING
OUTDOOR FAN/LIGHT
J
ARLINGTON, CP3540
N/A
CEILING
UNIT CEILING FAN
ROUGH -IN
K
SEAGULL, 31160EN3-839
LED
CHANDELIER
UNIT DINING ROOM
L
SEAGULL, 14520S-15
LED
CEILING
COMMON AREAS
M
LITHONIA LED STRIPLIGHT MNSL L46 ILL
MVOLT GZN 40K 80RI M6
LED
CEILING
SPRINKLER ROOM
N
CERAMIC KEYLESS SOCKET W/ LED BULBS
ALLIED MOULDED LH11P
LED
CEILING
GARAGES
R
LSI SDL4 LED 40L FL UNV DIM1 40 80CRI
LED
WALL/CEIL
ELEVATOR PIT
S
RAB, SLIMFC37N
LED
WALL
EXTERIOR WALL PACK
T
COORDINATE WITH OWNER
LED
WALL
COMMON AREA SCONCE
RM
BEST, RHLED-2-WP-9.6
LED
WALL
REMOTE EGRESS
EXIT/ EM
BEST, CLPU-2-R-W-RC
LED
WALL/CEIL
EXIT SIGN w/ EM. LIGHT
EXIT
BEST, EZRXTEU-2-R-W-EM
LED
WALL/CEIL
EXIT SIGN
EM
BEST, LEDR-1
LED
WALL
EMERGENCY LIGHT
WP
EXIT/EM
BEST CWLEZXTEUIRW-CW
LED
WALL
EXTERIOR EXIT SIGN w/
EMERGENCY LIGHT
WP EM
I BEST, RMR-I6-WP-LED
I LED
I WALL
I EXTERIOR EM. LIGHT
NOTES:
1. CONSTRUCTION SHALL COMPLY WITH THE 2009 INDIANA ELECTRICAL CODE,
2008 NFPA 70, 2010 INDIANA ENERGY CONSERVATION CODE, AND IN ALL
RESPECTS WITH APPLICABLE FEDERAL, STATE, COUNTY AND/OR LOCAL
STATUS, ORDINANCES, REGULATIONS, LAWS AND CODES.
2. ALL WORK SHOWN IS NEW AND BY THE ELECTRICAL TRADE UNLESS
OTHERWISE NOTED.
3. ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER
TRADES.
4. ELECTRICAL CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED
PERMITS UNLESS INSTRUCTED OTHERWISE.
5. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OPERATION
AND MAINTENANCE INSTRUCTION, AND ONE YEAR GUARANTEE,
COMMENCING ON DATE OF ACCEPTANCE BY OWNER.
6. RECEPTACLES IN DEMISING WALLS SHALL NOT BE INSTALLED BACK TO
BACK. RECEPTACLES SHALL BE OFFSET AT LEAST 24" CENTER TO CENTER
MEASURED HORIZONTALLY. BOXES MUST MEET UL #CEYY.R9379.
POSSIBLE MANUFACTURER 'ALLIED MOULDED PRODUCTS' #1098-N,
9336-BHGK, OR SIMILAR.
7. LAY OUTLET ON EDGE ABOVE COUNTER TOP.
8. ACCESSIBLE UNITS: OUTLETS IN ACCESSIBLE UNITS SHALL BE NO LOWER
THAN 18" A.A.F., AND SWITCHES SHALL BE NO HIGHER THAN 46" A.A.F..
9. EXTERIOR FIXTURES LOCATED AT BUILDING ENTRIES TO BE PHOTO CELL
ACTIVATED.
10. FEEDER AND BRANCH CONDUCTORS SHALL BE SIZED TO PREVENT
VOLTAGE DROP ACCORDING TO NEC 210-19 & 215-2
11. PROVIDE DEDICATED Y SWITCHED OUTLET BELOW SINK AREA FOR
DISPOSAL OTHER Yz IS FOR DISHWASHER. SWITCHED BELOW SINK AREA.
12. PROVIDE ROUGH -IN JUNCTION BOX WITH WHITE METAL COVER PLATE AND
WIRING TO WALL SWITCH FOR FUTURE INSTALLATION OF CEILING
FAN/LIGHT. LOCATE WHERE SHOWN ON UNIT ELEC. PLANS.
13. FIRESTOP ALL PENETRATIONS THRU RATED ASSEMBLIES PER CODE.
14. CHECK W/ SERVING POWER COMPANY TO ASSURE POWER, EQUIPMENT,
WIRING, ENTRANCE LOCATION, WORK RESPONSIBILITIES, ETC. ARE
COORDINATED AND COMPATIBLE W/ WORK AND IN ACCORDANCE W/ CODE.
15. PROVIDE LINE LOAD G.F.I.'S AS PER ELEC. CODE.
16. UNITS WITH MORE THAN ONE SMOKE DETECTOR SHALL BE
INTERCONNECTED AS ACTUATION OF ONE ACTUATES ALL DETECTORS
WITHIN UNIT. INSTALL FIRE ALARMS IN EACH BEDROOM.
17. PROVIDE ELECTRICAL RECEPTACLE FOR FUTURE USE (NOT SHOWN ON
PLANS) IN ATTIC SPACE NEAR CENTER OF STRUCTURE. COORDINATE WITH
OWNER. PLACE ON HOUSE PANEL.
18. ALL MECHANICAL EQUIPMENT (EXHAUST FANS, DISCONNECTS, AND
CONTROLLERS) ARE TO BE PROVIDED AND MOUNTED BY MECHANICAL
CONTRACTOR AND POWER WIRING ARE TO BE DONE BY E.C. LOW VOLTAGE
WIRING IS BY MECHANICAL CONTRACTOR.
19. ALL ELECTRICAL EQUIPMENT AND FIXTURES SERVING HALL, STAIRWAY,
GARAGES AND OTHER COMMON AREAS SHALL BE WIRED TO HOUSE PANEL.
HOUSE ELECTRICAL LOADS SHALL BE SEPARATELY METERED
20. PROVIDE AUTOMATIC LOCAL ALARM SYSTEM IN APARTMENT UNITS
& CORRIDORS PER NFPA 72 THAT IS ACTUATED BY THE FIRE
SPRINKLER SYSTEM. ADDITIONALLY, PROVIDE COMBINATION
AUDIBLE/VISUAL ALARM DEVICES IN ALL ADA APARTMENT UNITS &
ALL CORRIDORS.
21. PROVIDE WIRING FOR ALL APARTMENT ALARMS THAT PERMIT
FUTURE INSTALLATION OF COMBINATION AUDIBLE/STROBE ALARM
UNITS.
22. CONFIRM ALL REGISTER LOCATIONS WITH LIGHT FIXTURE
LOCATIONS.
23. EXTERIOR SITE LIGHTS TO BE COORDINATED WITH OWNER.
24. LIGHT FIXTURES TO BE COORDINATED WITH OWNERS.
25. HOUSE PANELS MOUNTED INSIDE A UNIT DEMISING WALL OR
CORRIDOR WALL REQUIRE PRE -ROCK DRYWALL BEHIND THE PANEL.
WALL SHALL BE RATED FOR 1 HOUR FIR CONSTRUCTION.
26. EXTERIOR STAIR LIGHTING TO BE CONTROLLED BY OCCUPANCY SENSOR.
ELECTRICAL CONTRACTOR NOTE:
1O ELECTRICAL CONTRACTOR (E.C.) SHALL VERIFY
LOCATION & MOUNTING HEIGHT OF ALL
ELECTRICAL OUTLETS, TELEPHONE OUTLETS, ETC.
WITH ARCHITECT, OWNER, & EQUIPMENT SUPPLIER
PRIOR TO ROUGH —IN.
20 E.C. TO COORDINATE LOCATION OF ELECTRICAL
EQUIPMENT WITH OTHER TRADES INCLUDING
SPRINKLER SYSTEM TO AVOID CONFLICTS. NOTIFY
ARCHITECT IF CONFLICTS EXIST.
O E.C. TO COORDINATE WORK AND PROVIDE
EQUIPMENT ACCEPTABLE TO POWER SUPPLIER
AND THEIR EQUIPMENT.
O THESE DRAWINGS ARE INTENDED TO DOCUMENT
THE GENERAL REQUIREMENTS FOR ELECTRICAL
SYSTEMS. THEY MAY NOT BE COMPLETE IN EVERY
RESPECT. THE ELECTRICAL CONTRACTOR IS
REQUIRED TO PROVIDE ALL NECESSARY LABOR,
EQUIPMENT, ACCESSORIES, ETC., FOR A COMPLETE
AND OPERATING INSTALLATION, WHETHER OR NOT
INDICATED ON THESE DOCUMENTS.
NOTE:
ALL OPENINGS OR PENETRATIONS (I.E. PLUMBING
VENTS, ETC.) THROUGH THE FIRE RATED WALLS,
CEILINGS AND/OR FLOOR SYSTEMS REQUIRE PROPER
PROTECTIVE FIRE STOPPING. FIRE COLLARS AND/OR
FIRE CAULKING SHALL BE PROPERLY INSTALLED,
LOCATED AT THE FIRST FLOOR LINE, SECOND FLOOR
CEILING AT HEIGHT OF TOP PLATES (AT BUILDINGS
WITH BASEMENTS ALSO LOCATE AT THE BASEMENT
FLOOR CEILING AT HEIGHT OF TOP PLATES, AND AT
FIRST FLOOR AT FINISHED FLOOR LINE) AND ANY
PENETRATIONS OF RATED WALL ASSEMBLIES.
Ow
19L.
Q
W
0
# DE5GRIFTION
U
w
N
Z
z
A
L
J
v
ESKER �R %,%
a LP;•��G\STERF�.•• 9�
;• No. 19500201
•:• STATE OF •'
DI SNP 0
Lu
I
V
DATE
Lu
v
v
v
v
Lu
0
w
z
Q
th
z
0
ll.l
GONSTRUGTION SET
0
NOVEME3ER 11, 2020
w
20022 °
E111