HomeMy WebLinkAboutE111 Overall First Floor Electrical Plan)RDINATE DUPLEXES )NE LINES, CABLE LINES ,H OWNER BATE UNIT HEATER TECT WITH M.C. OVERALL FIRST FLOOR ELECTRICAL PLAN SCALE: 1/4" = 1' - 0" ELECTRICAL SYMBOL KEY SWITCH 4 3-WAY OR 4-WAY SWITCH �GFI GROUND FAULT INTERRUPTER (GFI) 220 VOLT OUTLET 120 VOLT OUTLET; IN UNITS/GUEST: ARC FAULT CIRCUIT INTERUPTER OUTLET OR CONNECTED TO AFCI BREAKER =11!�_ HALF -SWITCHED OUTLET =&WP WEATHER PROOF OUTLET �p DEDICATEDDMEDCADTEDLEX SINGLE C RECP. FOR MICRO O FAN RATED CEILING BOX W/ WHITE COVER TV AND DATA = (1)RG-6 COAX (1)CAT5E A TV AND DATA = (1)RG-6 COAX (2)CAT5E EDP UNIT ELECTRICAL PANEL O HARD WIRED SMOKE/CO DETECTOR t DISCONNECT JUNCTION BOX CO AND NO2 SENSOR PC PHOTO -CELL LIGHT/ DAY LIGHT OC OCCUPANCY LIGHT/ MOTION LIGHT n AUDIBLE FIRE ALARM W/ STROBE ALL COMMON AREAS, ADA UNITS. AUDIBLE FIRE ALARM ALL OTHER UNITS; EXIT SIGN EMERGENCY LIGHT (>-H REMOTE HEAD EXTERIOR EMERGENCY LIGHT BBH BASEBOARD HEATER 1000W 0 HOUSE PANEL WALL EXHAUST VENT EXHAUST VENT THERMOSTAT 2'X4' LED TROFFERS FIXTURE LED DRY STRIPLIGHT SURFACE MOUNTED FIXTURE ® SURFACE MOUNTED FIXTURE 1-0 WALL MOUNTED FIXTURE EXIT SIGN W/ EMERGENCY LIGHT =&F 120 VOLT OUTLET IN FLOOR =&4 120 VOLT QUAD OUTLET ELECTRICAL FIXTURE SCHEDULE TYPE MFGR & MODEL NUMBER LAMP TYPE MOUNTING DESCRIPTION & USE A SEAGULL, 14520S-15 LED CEILING UNIT CLOSET, BATH, LAUNDRY, FOYER B SEAGULL, 61160EN3-839 LED PENDANT UNIT KITCHEN BAR C SEAGULL, 41162-839 LED WALL BATHROOM VANITY D BROAN 744 VERIFY WITH M.C. LED RECESSED SHOWER LIGHT/VENT E CEILING FAN ROYAL STAR 1052BN-ES LED CEILING BEDROOM CEIL FAN F SEE MECHANICAL SHEETS N/A WALL EXHAUST FAN G SEAGULL, 14520S-15 LED RECESSED GREAT ROOM, BEDROOMS, KITCHEN, CORRIDORS H SEAGULL, 14520S-15 LED RECESSED OUTDOOR PATIOS AND LIVING I RP LIGHTING BOSQUE 1018W FAN LED CEILING OUTDOOR FAN/LIGHT J ARLINGTON, CP3540 N/A CEILING UNIT CEILING FAN ROUGH -IN K SEAGULL, 31160EN3-839 LED CHANDELIER UNIT DINING ROOM L SEAGULL, 14520S-15 LED CEILING COMMON AREAS M LITHONIA LED STRIPLIGHT MNSL L46 ILL MVOLT GZN 40K 80RI M6 LED CEILING SPRINKLER ROOM N CERAMIC KEYLESS SOCKET W/ LED BULBS ALLIED MOULDED LH11P LED CEILING GARAGES R LSI SDL4 LED 40L FL UNV DIM1 40 80CRI LED WALL/CEIL ELEVATOR PIT S RAB, SLIMFC37N LED WALL EXTERIOR WALL PACK T COORDINATE WITH OWNER LED WALL COMMON AREA SCONCE RM BEST, RHLED-2-WP-9.6 LED WALL REMOTE EGRESS EXIT/ EM BEST, CLPU-2-R-W-RC LED WALL/CEIL EXIT SIGN w/ EM. LIGHT EXIT BEST, EZRXTEU-2-R-W-EM LED WALL/CEIL EXIT SIGN EM BEST, LEDR-1 LED WALL EMERGENCY LIGHT WP EXIT/EM BEST CWLEZXTEUIRW-CW LED WALL EXTERIOR EXIT SIGN w/ EMERGENCY LIGHT WP EM I BEST, RMR-I6-WP-LED I LED I WALL I EXTERIOR EM. LIGHT NOTES: 1. CONSTRUCTION SHALL COMPLY WITH THE 2009 INDIANA ELECTRICAL CODE, 2008 NFPA 70, 2010 INDIANA ENERGY CONSERVATION CODE, AND IN ALL RESPECTS WITH APPLICABLE FEDERAL, STATE, COUNTY AND/OR LOCAL STATUS, ORDINANCES, REGULATIONS, LAWS AND CODES. 2. ALL WORK SHOWN IS NEW AND BY THE ELECTRICAL TRADE UNLESS OTHERWISE NOTED. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES. 4. ELECTRICAL CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED PERMITS UNLESS INSTRUCTED OTHERWISE. 5. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OPERATION AND MAINTENANCE INSTRUCTION, AND ONE YEAR GUARANTEE, COMMENCING ON DATE OF ACCEPTANCE BY OWNER. 6. RECEPTACLES IN DEMISING WALLS SHALL NOT BE INSTALLED BACK TO BACK. RECEPTACLES SHALL BE OFFSET AT LEAST 24" CENTER TO CENTER MEASURED HORIZONTALLY. BOXES MUST MEET UL #CEYY.R9379. POSSIBLE MANUFACTURER 'ALLIED MOULDED PRODUCTS' #1098-N, 9336-BHGK, OR SIMILAR. 7. LAY OUTLET ON EDGE ABOVE COUNTER TOP. 8. ACCESSIBLE UNITS: OUTLETS IN ACCESSIBLE UNITS SHALL BE NO LOWER THAN 18" A.A.F., AND SWITCHES SHALL BE NO HIGHER THAN 46" A.A.F.. 9. EXTERIOR FIXTURES LOCATED AT BUILDING ENTRIES TO BE PHOTO CELL ACTIVATED. 10. FEEDER AND BRANCH CONDUCTORS SHALL BE SIZED TO PREVENT VOLTAGE DROP ACCORDING TO NEC 210-19 & 215-2 11. PROVIDE DEDICATED Y SWITCHED OUTLET BELOW SINK AREA FOR DISPOSAL OTHER Yz IS FOR DISHWASHER. SWITCHED BELOW SINK AREA. 12. PROVIDE ROUGH -IN JUNCTION BOX WITH WHITE METAL COVER PLATE AND WIRING TO WALL SWITCH FOR FUTURE INSTALLATION OF CEILING FAN/LIGHT. LOCATE WHERE SHOWN ON UNIT ELEC. PLANS. 13. FIRESTOP ALL PENETRATIONS THRU RATED ASSEMBLIES PER CODE. 14. CHECK W/ SERVING POWER COMPANY TO ASSURE POWER, EQUIPMENT, WIRING, ENTRANCE LOCATION, WORK RESPONSIBILITIES, ETC. ARE COORDINATED AND COMPATIBLE W/ WORK AND IN ACCORDANCE W/ CODE. 15. PROVIDE LINE LOAD G.F.I.'S AS PER ELEC. CODE. 16. UNITS WITH MORE THAN ONE SMOKE DETECTOR SHALL BE INTERCONNECTED AS ACTUATION OF ONE ACTUATES ALL DETECTORS WITHIN UNIT. INSTALL FIRE ALARMS IN EACH BEDROOM. 17. PROVIDE ELECTRICAL RECEPTACLE FOR FUTURE USE (NOT SHOWN ON PLANS) IN ATTIC SPACE NEAR CENTER OF STRUCTURE. COORDINATE WITH OWNER. PLACE ON HOUSE PANEL. 18. ALL MECHANICAL EQUIPMENT (EXHAUST FANS, DISCONNECTS, AND CONTROLLERS) ARE TO BE PROVIDED AND MOUNTED BY MECHANICAL CONTRACTOR AND POWER WIRING ARE TO BE DONE BY E.C. LOW VOLTAGE WIRING IS BY MECHANICAL CONTRACTOR. 19. ALL ELECTRICAL EQUIPMENT AND FIXTURES SERVING HALL, STAIRWAY, GARAGES AND OTHER COMMON AREAS SHALL BE WIRED TO HOUSE PANEL. HOUSE ELECTRICAL LOADS SHALL BE SEPARATELY METERED 20. PROVIDE AUTOMATIC LOCAL ALARM SYSTEM IN APARTMENT UNITS & CORRIDORS PER NFPA 72 THAT IS ACTUATED BY THE FIRE SPRINKLER SYSTEM. ADDITIONALLY, PROVIDE COMBINATION AUDIBLE/VISUAL ALARM DEVICES IN ALL ADA APARTMENT UNITS & ALL CORRIDORS. 21. PROVIDE WIRING FOR ALL APARTMENT ALARMS THAT PERMIT FUTURE INSTALLATION OF COMBINATION AUDIBLE/STROBE ALARM UNITS. 22. CONFIRM ALL REGISTER LOCATIONS WITH LIGHT FIXTURE LOCATIONS. 23. EXTERIOR SITE LIGHTS TO BE COORDINATED WITH OWNER. 24. LIGHT FIXTURES TO BE COORDINATED WITH OWNERS. 25. HOUSE PANELS MOUNTED INSIDE A UNIT DEMISING WALL OR CORRIDOR WALL REQUIRE PRE -ROCK DRYWALL BEHIND THE PANEL. WALL SHALL BE RATED FOR 1 HOUR FIR CONSTRUCTION. 26. EXTERIOR STAIR LIGHTING TO BE CONTROLLED BY OCCUPANCY SENSOR. ELECTRICAL CONTRACTOR NOTE: 1O ELECTRICAL CONTRACTOR (E.C.) SHALL VERIFY LOCATION & MOUNTING HEIGHT OF ALL ELECTRICAL OUTLETS, TELEPHONE OUTLETS, ETC. WITH ARCHITECT, OWNER, & EQUIPMENT SUPPLIER PRIOR TO ROUGH —IN. 20 E.C. TO COORDINATE LOCATION OF ELECTRICAL EQUIPMENT WITH OTHER TRADES INCLUDING SPRINKLER SYSTEM TO AVOID CONFLICTS. NOTIFY ARCHITECT IF CONFLICTS EXIST. O E.C. TO COORDINATE WORK AND PROVIDE EQUIPMENT ACCEPTABLE TO POWER SUPPLIER AND THEIR EQUIPMENT. O THESE DRAWINGS ARE INTENDED TO DOCUMENT THE GENERAL REQUIREMENTS FOR ELECTRICAL SYSTEMS. THEY MAY NOT BE COMPLETE IN EVERY RESPECT. THE ELECTRICAL CONTRACTOR IS REQUIRED TO PROVIDE ALL NECESSARY LABOR, EQUIPMENT, ACCESSORIES, ETC., FOR A COMPLETE AND OPERATING INSTALLATION, WHETHER OR NOT INDICATED ON THESE DOCUMENTS. NOTE: ALL OPENINGS OR PENETRATIONS (I.E. PLUMBING VENTS, ETC.) THROUGH THE FIRE RATED WALLS, CEILINGS AND/OR FLOOR SYSTEMS REQUIRE PROPER PROTECTIVE FIRE STOPPING. FIRE COLLARS AND/OR FIRE CAULKING SHALL BE PROPERLY INSTALLED, LOCATED AT THE FIRST FLOOR LINE, SECOND FLOOR CEILING AT HEIGHT OF TOP PLATES (AT BUILDINGS WITH BASEMENTS ALSO LOCATE AT THE BASEMENT FLOOR CEILING AT HEIGHT OF TOP PLATES, AND AT FIRST FLOOR AT FINISHED FLOOR LINE) AND ANY PENETRATIONS OF RATED WALL ASSEMBLIES. Ow 19L. Q W 0 # DE5GRIFTION U w N Z z A L J v ESKER �R %,% a LP;•��G\STERF�.•• 9� ;• No. 19500201 •:• STATE OF •' DI SNP 0 Lu I V DATE Lu v v v v Lu 0 w z Q th z 0 ll.l GONSTRUGTION SET 0 NOVEME3ER 11, 2020 w 20022 ° E111