HomeMy WebLinkAboutM500 Mechanical DetailsNOTES:
1. ALL DRYER EXHAUST DUCT JOINTS SHALL OVER LAP IN THE DIRECTION OF AIR
FLOW.
2. NO SCREWS SHALL BE ALLOWED IN THE DRYER EXHAUST DUCT AND ALL
JOINTS SHALL BE SEALED WITH FOIL FACED TAPE.
3. DRYER EXHAUST SYSTEM IS DESIGNED BASED ON MANUFACTURER
WASHER/DRYER UNITS. CONTRACTOR SHALL USE SHEET METAL ROUND DUCTWORK
AND MINIMIZE THE USE OF FLEXIBLE DUCTWORK.
CEILING
EXTERIOR WALL
90°, 4"∅ RADIUS
ELBOW, TYPICAL
WASHER
4"∅ RIGID DUCT
DRYER
INSTALL AS PER
MANUFACTURER'S
INSTRUCTIONS.
PORTION OF EXTERIOR WALL
LOUVER WITH BACK-DRAFT
FLAPPER.
REFER TO ARCHITECTURAL
DRAWINGS.
FLEXIBLE CONNECTION
RECOMMENDED
CEILING MOUNTED SUPPLY REGISTER INSTALLATION DETAIL
NOT TO SCALE
INSULATED FLEX DUCT
CEILING
SUPPLY AIR REGISTER
WITH OPPOSED
BLADE
VOLUME DAMPER
SUPPLY DUCT
RADIATION DAMPER
AT RATED CEILINGS
DRYER EXHAUST DETAIL
SCALE: NOT TO SCALE
CONNECTION
REFRIGERANT GAUGE
CONTROL WIRING
REFRIGERANT LIQUID LINE
WITH INSULATION
REFRIGERANT SUCTION LINE
SERVICE VALVES
CONDENSING UNIT
FAN GUARD
AIR-COOLED CONDENSING UNIT DETAIL
NOT TO SCALE
CONDENSING UNIT MOUNTING DETAIL
NOT TO SCALE REFRIGERANT PIPING ROOF HOOD & CURB DETAIL
NOT TO SCALE
(NOTE: COORDINATE CURBS & FLASHING WITH SPECIFIED ROOF CONSTRUCTION)
LINESETS22" *6"12"
28"12" *12" *22"RI
G EEIS
PE60860351
No.REENIGNELANOISSEFORPDOUGLAS.R MOO
RET R
NNDIA A
STATE OF DEMOORE ENGINEERING
SERVICES, INC.
6340 LaPas Trail
Indianapolis, IN 46268
Phone (317) 291-1052
FAX (317) 298-2729 ARCHITECTCLIENTPROJECTDRAWING TITLESHEET PROJECT INFOREVISIONS20022
#DESCRIPTION DATEMAGNOLIACONDOMINIUMS126TH & RANGELINE RDCARMEL, IN100% Contract Set GC/CMSEAL10/07/2020
M500 MECHANICAL DETAILS