HomeMy WebLinkAboutM500 Mechanical DetailsNOTES: 1. ALL DRYER EXHAUST DUCT JOINTS SHALL OVER LAP IN THE DIRECTION OF AIR FLOW. 2. NO SCREWS SHALL BE ALLOWED IN THE DRYER EXHAUST DUCT AND ALL JOINTS SHALL BE SEALED WITH FOIL FACED TAPE. 3. DRYER EXHAUST SYSTEM IS DESIGNED BASED ON MANUFACTURER WASHER/DRYER UNITS. CONTRACTOR SHALL USE SHEET METAL ROUND DUCTWORK AND MINIMIZE THE USE OF FLEXIBLE DUCTWORK. CEILING EXTERIOR WALL 90°, 4"∅ RADIUS ELBOW, TYPICAL WASHER 4"∅ RIGID DUCT DRYER INSTALL AS PER MANUFACTURER'S INSTRUCTIONS. PORTION OF EXTERIOR WALL LOUVER WITH BACK-DRAFT FLAPPER. REFER TO ARCHITECTURAL DRAWINGS. FLEXIBLE CONNECTION RECOMMENDED CEILING MOUNTED SUPPLY REGISTER INSTALLATION DETAIL NOT TO SCALE INSULATED FLEX DUCT CEILING SUPPLY AIR REGISTER WITH OPPOSED BLADE VOLUME DAMPER SUPPLY DUCT RADIATION DAMPER AT RATED CEILINGS DRYER EXHAUST DETAIL SCALE: NOT TO SCALE CONNECTION REFRIGERANT GAUGE CONTROL WIRING REFRIGERANT LIQUID LINE WITH INSULATION REFRIGERANT SUCTION LINE SERVICE VALVES CONDENSING UNIT FAN GUARD AIR-COOLED CONDENSING UNIT DETAIL NOT TO SCALE CONDENSING UNIT MOUNTING DETAIL NOT TO SCALE REFRIGERANT PIPING ROOF HOOD & CURB DETAIL NOT TO SCALE (NOTE: COORDINATE CURBS & FLASHING WITH SPECIFIED ROOF CONSTRUCTION) LINESETS22" *6"12" 28"12" *12" *22"RI G EEIS PE60860351 No.REENIGNELANOISSEFORPDOUGLAS.R MOO RET R NNDIA A STATE OF DEMOORE ENGINEERING SERVICES, INC. 6340 LaPas Trail Indianapolis, IN 46268 Phone (317) 291-1052 FAX (317) 298-2729 ARCHITECTCLIENTPROJECTDRAWING TITLESHEET PROJECT INFOREVISIONS20022 #DESCRIPTION DATEMAGNOLIACONDOMINIUMS126TH & RANGELINE RDCARMEL, IN100% Contract Set GC/CMSEAL10/07/2020 M500 MECHANICAL DETAILS