HomeMy WebLinkAboutP500 Plumbing Details DWVFOR INSULATED PIPING)TO STRUCTURE1/2" HANGER RODWHERE REQUIREDFIBERGLASONLYINSULATED PIPEMETAL SHIELD FOR20 GAUGE SHEETBARRIER (TYPICALCONTINUOUS VAPORNUT (TYPICAL)HANGERPIPINGSTRAPTHRU BOLTNOTES:REFER TO RELATED SECTIONS OF THE SPECIFICATIONS FOR INFORMATION REGARDING FLASHING MEMBRANE AND FIRESTOPSEALANTFINISH FLOORLCPROVIDE NEW CONCRETE TO MATCHEXISTING FLOORFLASHING MEMBRANEREMOVE EXISTING CONCRETETO RECIEVE FLASHING CLAMPFIRESTOP SEALANTCORE HOLE TO RECIEVEDRAIN BODYFLOOR DRAIN BODYEXISTING SLABFLOOR DRAIN GRATETRAP SEALTO GRADE DETAILAT END OF LINECLEANOUT OCCURS1/8 BEND IFWASTE LINELENGTH TO SUIT WASTE LINE1/8 BENDFINISHED GRADEHEADWITH COUNTER SUNKBRASS CLEANOUT PLUGFLOOR LINESAME AS CLEANOUTBALANCE OF PIPE1/8 BENDAREASFOR CARPETEDCARPET MARKEROF FLOORTO BE FLUSH WITH TOPCOVER. TOP OF COVERCLEANOUT AND ACCESSCLEANOUT TO GRADEFLOOR CLEANOUTNOTE: LOCATE PIPING 1 1/2"MIN. CLEARANCE OF GYPSUMBOARDCAULK AIRTIGHTWITH ACOUSTICALOR FIRE-RATEDSEALANTFLOOR CONSTRUCTIONSAFING BATT INSULATIONBACKER RODPIPE RISER CLAMPSTEEL SHIM (OPTIONAL)3/4" NEOPRENE PAD0.2500NOTE:FIRE SEALANTS AND PIPEPENETRATION SHALL HAVE ANF-RATING AND NO LESS THANTHE REQUIRED FIRE RESISTANCERATING OF THE WALLPENETRATED.SANITARY, DRAINAGEOR WATER PIPENON-SECURE SPACESECURE SPACEPVC PIPE SLEEVERATED CAULK.1/4" BEAD OF FIREDISHWASHERLOOPED HIGH AND SECURELYFASTENED TO COUNTER OR WALL2"FOOD-WASTEGRINDER1/2" TO FOODWASTE GRINDER INLETSUMP RECEIVERCOLUMNCLAMP TO WALL OR COLUMNOFFSET (IF REQUIREDBY JOB CONDITION)ROOF DRAININSULATIONUNDERDECKCLAMPPLUGGED SLEEVENOTE:1. PROVIDE RISER CLAMP AT ALL OTHER FLOOR PENETRATIONS.2. HOLD HORIZONTAL PIPING AT DESIGN SLOPE (1/4" PERFOOT FOR 2" AND 3" PIPE, 1/8" PER FOOT FOR LARGER PIPE)TO ALLOW MAXIMUM UTILIZATION OF AVAILABLE PIPE SPACE INBUILDING.TRAPEZE HANGER (3/4" PIPE FORPIPING UP TO 5", 1" PIPE FORLARGER PIPING.)ALL THREAD ROD (3/8" FOR PIPING UP TO 6",1/2" FOR LARGER PIPING)CONCRETE INSERTHOLD BELL OF HUB TIGHTTO BOTTOM OF FLOORCONSTRUCTIONEXTEND SLEEVE 2" ABOVEFINISHED SLABEXTEND SLEEVE 2"ABOVE LOCATIONS WHERETOPPING SLAB EXISTSPIPE SLEEVEFLOOR SLABTOPPING SLAB (REFERTO ARCHITECTURAL DRAWINGSFOR LOCATIONS)FOR PENETRATIONS IN FIRE RATED FLOORS,FILL VOID OR CAVITY WITH MATERIALSCLASSIFIED BY UNDERWRITERS LABORATORIES INC.FOR USE IN THROUGH-PENETRATION FIRESTOPSYSTEM OR U.L. CLASSIFIED THROUGH-PENETRATIONFIRESTOP DEVICENO SCALEA AREFER TO SPECIFICATIONS FOR ADDITIONAL SLEEVE REQUIREMENTS18 GAUGE CONTINUOUS SHEET METALENCLOSURE FOR PENETRATIONS WITHFIRE-STOP MATERIAL. ENCLOSURESHALL NOT BE ATTACHED TO PIPE ORINSULATION.SECTION A-ANO SCALETOPPING SLAB (REFER TO THE ARCHITECTURALDRAWINGS FOR LOCATIONS)FOR PENETRATIONS IN FIRE-RATED FLOORS, FILL VOID, ORCAVITY WITH MATERIALS CLASSIFIED BY UNDERWRITERSLABORATORIES INC. FOR USE IN THROUGH-PENETRATIONFIRESTOP SYSTEM OR U.L. CLASSIFIEDTHROUGH-PENETRATION FIRESTOP DEVICE1/4" TO 3/8" GAP BETWEEN PIPE AND COREPIPE AND/OR CONDUIT1" TYPOUTSIDE SURFACEOF PIPE (ORINSULATION)1/4" TO 3/8" GAP BETWEENEDGE OFENCLOSURE ANDPIPESLEEVEUNDERSIDE PLAN VIEWOR 3 FT. ABOVE STRUCTURE.10 FT. (MIN.) FROM ANY WALLVENT STACK OUTLET TO BENOTE:ROOFINGCONSTRUCTIONROOFFLASHING SLEEVEVENT STACKVENT STACK EXTENSIONHOLE IN WALLFINISH BY OTHERSWOOD OR STEELFRAMING STUDSCREW MOUNTINGBRACKET TO STUDWASH MACHINE SERVICECONNECTION BOXOVERFLOW TRAY2" WASTE OUTLET1/2" CW SUPPLYTOP OF BOXTOP OF MACHINE3-1/2"XX" TO FL.SHOCK ABSORBERTYPICAL SERVICE STOPRIGEEISPE60860351No.REENIGNELANOISSEFORPDOUGLAS.RMO ORETR NNDIAASTATE OFDEMOORE ENGINEERINGSERVICES, INC.6340 LaPas TrailIndianapolis, IN 46268Phone (317) 291-1052FAX (317) 298-2729ARCHITECTCLIENTPROJECTDRAWING TITLESHEET PROJECT INFOREVISIONS20022#DESCRIPTIONDATEMAGNOLIACONDOMINIUMS126TH & RANGELINE RDCARMEL, IN100% Contract SetGC/CMSEAL10/07/2020P500PLUMBING DETAILS -DWV