HomeMy WebLinkAboutA010.1 Finish Plan and Door Schedule2'-3" 2'-9" 2'-6" 2'-6" 2'-6" 2'-6" 2'-3" COPIER BY TENANT COPIER BY TENANT 9'-0" CLEAR PLASTIC LAMINATE (PL1) WALL CABINETS (SEE CASEWORK NOTE 1) 25" DEEP PLASTIC LAMINATE (PL2) COUNTERTOP PLASTIC LAMINATE (PL1) BASE CABINETS (SEE CASEWORK NOTE 1) 3'-0" 1'-9" 2'-6" PLASTIC LAMINATE (PL1) FILLER PANEL CONFIRM EXACT COPIER SPACE REQUIREMENTS WITH TENANT 2'-9" F1 3'-0" 3'-4" 2" 2" REFER TO DOOR SCHED. 2" REFER TO DOOR SCHED. D1 3'-0" 3'-0" REFER TO DOOR SCHED. SLIDING DOOR HARDWARE AS SCHEDULED, TOP TRACK 34"W x 82"H DRYWALL WRAPPED OPENING D2 OFFICE 211 OFFICE 210 OFFICE 209 OFFICE 208 OFFICE 207 OFFICE 206 BREAK 204 STG/IT 205 CONFERENCE 213 REFRIG BY TENANT CONFERENCE 202 FILES/COPY 203 ENTRY 201 OPEN OFFICE 214 DW PROVIDE (6) WOOD SHELVES TO BE PAINTED (PT4). SHELVES TO BE 2" THICK AND ALL MOUNTING HARDWARE TO BE CONCEALED VIF 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" 1'-2" VINYL BASE AS SPECIFIED DOOR SCHEDULE INTERIOR DETAILS A211 DATE DESCRIPTION ISSUE 02.24.21 REVIEW SET 03.09.21 PERMIT SET REVISIONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY EICHHORN & EICHHORN MERIDIAN TOWER | SUITE 280 10201 N. ILLINOIS STREET, INDIANAPOLIS, IN 46290 MS MS/NP 2020.169 2ND FLOOR FINISH PLAN NOTES AREA NOT IN CONTRACT AREA OF WORK FINISH PLAN FINISH PLAN/ CASEWORK NOTES EXISTING FLOORING TRANSITION TO REMAIN. IF NEEDED, PROVIDE JOHNSONITE SLIMLINE SLT-XX-F PROFILE TRANSITION STRIP AT FLOORING TRANSITION; COLOR: 20 CHARCOAL. CONTRACTOR MUST PROVIDE LEVELING LATEX SUCH THAT HEIGHTS OF MATERIALS ARE APPROPRIATE FOR USE WITH SPECIFIED PROFILE TRANSITION. BE AWARE TRANSITION STRIP MUST BE ORDERED IN A TIMELY MANNER AS IT IS NOT ALWAYS IMMEDIATELY AVAILABLE. TENANT SIDE OF DOOR/FRAME TO BE PAINTED TO MATCH NEW SUITE STANDARD. CORRIDOR SIDE OF DOOR/FRAME TO REMAIN AS IS. WINDOW FRAME IN THIS LOCATION TO BE PAINTED (PT4) EXISTING DOOR FRAME TO BE PAINTED (PT4) AND EXISTING DOOR TO BE PAINTED (PT5). 0 1' 2' 4' ELEVATION - FILES/COPY 203 A211 2 0 2' 4' 8' 16' HARDWARE LEGEND R1. PROVIDE 3'-0" W X 7'-0"H DRYWALL OPENING WITH WALL MOUNTED HARDWARE REQUIRED FOR SLIDING "BARN" DOOR ASSEMBLY. PROVIDE BOTTOM CATCH AND STOP AS REQUIRED. CONTRACTOR TO PROVIDE CUT SHEETS FOR TENANT APPROVAL PRIOR TO ORDERING. DESIGN INTENT IS FOR MOUNTING HARDWARE TO BE ABOVE DOOR OPENING AND DOOR TO EXTEND TO FLOOR. ENSURE THAT CLEAR OPENING IS MINIMUM OF 34" WHEN DOOR IS FULLY OPEN. CONTRACTOR TO WORK WITH SDI TO ENSURE THIS INTENT IS MET. R2. PROVIDE NEW TRILOGY KEYPAD ON DOOR AS REQUIRED. CONFIRM SECURITY REQUIRED WITH TENANT. PROVIDE SEPARATE PRICE FOR DOOR TO RECEIVE POWER AND CARD READER. R3. TENANT SIDE OF DOOR TO RECIEVE PAINT (PT5). CORRIDOR SIDE TO REMAIN AS-IS. REMARKS DOOR/FRAME TYPES CARPET FLOOR COVERINGS MFG: MOHAWK GROUP TYPE: MODULAR PATTERN: ACADEMIC VIEW TILE BT433 COLOR: PLATINUM 924 WALL BASE MFG: JOHNSONITE TYPE: 4" VINYL COVE, 1 8" GAUGE COLOR: 50 WHITE ALL FINISHES SHALL MEET ALL CLASS A FIRE RATINGS AND COMPLY WITH CHAPTER 8 OF INTERNATIONAL BUILDING CODE. FINISH LEGEND 1. REFER TO LEGEND FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 2. CONTRACTOR TO EVALUATE EXISTING FLOORING CONDITIONS AFTER DECONSTRUCTION IS COMPLETE AND PREP AS NECESSARY PER MANUFACTURERS RECOMMENDATIONS. SEALCOAT THE CONCRETE FLOOR PRIOR TO LAYING ADHESIVE IF DEEMED NECESSARY. 3. IF FINISH SUBMITTALS ARE REQUESTED AS PART OF THIS SCOPE, THEY ARE TO BE SUBMITTED IN DIGITAL FORMAT. GENERAL FINISH NOTES WALL FINISHES MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: SW 7005 PURE WHITE FINISH: EGGSHELL CASEWORK FINISHES MFG: FORMICA COLOR: 8792 WINTER SKY - MATTE FINISH MFG: PIONITE COLOR: SABLE SUEDE 021 MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: SW 7065 ARGOS FINISH: EGGSHELL PAINT PLASTIC LAMINATE CARPET NOTE: ALL MANUFACTURERS PARTICIPATES IN SCHOTT DESIGN'S RECYCLING NO COST ADD TO CLIENT OR PROJECT PROCESS. REFER TO SCHOTT DESIGN DECONSTRUCTION NOTES ON T111 AND D111 FOR PROCESS DETAILS. GENERAL NOTE: CONTRACTOR TO CONFIRM THAT SINKS NOTED IN ELEVATIONS PROPERLY COORDINATE WITH WIDTH AND DEPTH OF BASE CABINET PRIOR TO ORDERING. 1. PROVIDE AWI CUSTOM GRADE, FLUSH-OVERLAY CABINETS. FABRICATE WITH PLASTIC LAMINATE COVERED MDO BOARD AS NOTED IN ELEVATIONS. COORDINATE QUANTITIES IN ELEVATIONS. - WHERE 24"D COUNTERTOPS ARE NOTED ON ELEVATIONS, PROVIDE 23"D BASE CABINETS; WHERE 25"D COUNTERTOPS ARE NOTED ON ELEVATIONS, PROVIDE 24"D BASE CABINETS - ALL UPPER CABINETS TO BE 12"D, UNO - 4" BASE AT CABINETS TO BE VINYL BASE AS SPECIFIED, UNO - PULLS: 4" WIRE PULLS DOOR/FRAME NOTES 1. REUSE DOORS FROM DECONSTRUCTION WHERE POSSIBLE; TOUCH UP EXISTING DOOR STAIN AS REQUIRED. PROVIDE NEW BUILDING STANDARD DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS TO MATCH EXISTING. PRE-MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS. 2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS. REUSE EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW DOOR HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD. PROVIDE ADA ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS. 3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED. REUSE EXISTING FROM DEMOLITION WHERE POSSIBLE. IF FRAMES ARE NOT BEING REPAINTED, TOUCH UP EXISTING FRAMES TO BE REUSED. 4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN. 5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND LOCKSETS. 6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS. 7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: · 7'-0" HT. TO HAVE 3 HINGES · GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES · FINISH TO MATCH HARDWARE SET 8. PROVIDE (1) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE NOTED. 9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE BLOCKING BEHIND WALL STOP. 10. PROVIDE SEPARATE PRICE TO PAINT ALL DOORS AND FRAMES. DOOR SCHEDULE # DIMENSIONS DOOR FRAME HARDWARE REM. 02 03 07 R1 08 09 10 11 14 TYPE MATERIAL FINISH TYPE MATERIAL FINISH 3'-0"x7'-0"x1 3 4" D1 -- F1 TIMELY PT4 PS D2 DRYWALL WRAPPED OPENING SEE REMARK D1 OL RELOCATED NEW RELOCATED RELOCATED SWING LH -- RH 3'-0"x7'-0"x1 3 4" RH D1 -- F1 RELOCATED LH D1 -- F1 OL OL CL CLOSER CH COAT HOOK CR CARD READER BY TENANT (N.I.C.) DB DEADBOLT DL DUMMY LEVER EL ELECTROMAGNETIC LOCK (PER IBC 2012) ES ELECTRIC STRIKE BY TENANT (N.I.C.) FP FOOT PULL - STEP N PULL HANDS FREE DOOR OPENER SNPE-B H HOLD OPEN KP KICK PLATE KS KICK STOP OL OFFICE LOCKSET PH PANIC HARDWARE PL PRIVACY LOCKSET PP PUSH/PULL PS PASSAGE LATCHSET PV PIVOT HINGE RL ROLLER LATCHES SL STOREROOM LOCKSET TS TOP STRIKES RELOCATED RELOCATED 3'-0"x7'-0"x1 3 4" 3'-0"x7'-0"x1 3 4" 3'-0"x7'-0"x1 3 4" 3'-0"x7'-0"x1 3 4" SOLID CORE WOOD VNR. -- -- -- 3'-0"x7'-0"x1 3 4" LH RH D1 D1 F1 F1 F1 OL CR, ES, SL, CL 0 1' 2' 4' ELEVATION - OPEN OFFICE 214 A211 1 EXISTING FLOORING TO REMAIN EXISTING CABINETS TO REMAIN PT5 TIMELY TIMELY TIMELY TIMELY TIMELY MFG: SHERWIN WILLIAMS (DOOR AND WINDOW FRAMES) PRIMER: PRO-CRYL TOP COAT: PRO INDUSTRIAL RECATALYZED WATERBASED EPOXY K46W151 COLOR: SW 7005 PURE WHITE FINISH: SEMI-GLOSS INSTALL: PREP AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS FOR MAXIMUM ADHESION. THIS INCLUDES CLEANING AND SCUFF SANDING PRIOR TO APPLYING NEW FINISH. APPLY USING SPRAY APPLICATION. PT4 MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: SW 9163 TIN LIZZIE FINISH: EGGSHELL MFG: SHERWIN WILLIAMS (DOORS) PRIMER: MULTI-PURPOSE LATEX PRIMER B51W450 TOP COAT: SOLO COLOR: SW 7068 GRIZZLE GRAY FINISH: SEMI- GLOSS INSTALL: PREP AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS FOR MAXIMUM ADHESION. THIS INCLUDES CLEANING AND SCUFF SANDING PRIOR TO APPLYING NEW FINISH. APPLY USING SPRAY APPLICATION. PT5 PT5 PT5 PT5 PT5 PT5 PT4 PT4 PT4 PT4 EXISTING -- -- -- -- -- -- -- -- SEE REMARK R2,R3 04/07/21