Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M003.0
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by 84 Components - 0783. March 12,2021 Liu, Xuegang Pages or sheets covered by this seal: I45169024 thru I45169060 My license renewal date for the state of Indiana is July 31, 2022. 23598-23598A TG184 RF B IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss CE01 Truss Type GABLE Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169024 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:45 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-XNmeIVhbL?hhGDOJIjnuijTW82D3Ngb0APdFErzbk2m Scale = 1:37.1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 26 25 24 23 22 21 20 19 18 17 16 4x4 3x4 5x6 3x4 20-0-0 20-0-0 -1-0-0 1-0-0 10-0-0 10-0-0 20-0-0 10-0-0 21-0-0 1-0-0 0-6-05-6-00-6-06.00 12 Plate Offsets (X,Y)-- [21:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.08 0.05 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 0.00 (loc) 14 15 14 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 90 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 20-0-0. (lb) - Max Horz 2=72(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 2, 22, 23, 24, 25, 26, 20, 19, 18, 17, 16, 14 Max Grav All reactions 250 lb or less at joint(s) 2, 21, 22, 23, 24, 25, 20, 19, 18, 17, 14 except 26=255(LC 1), 16=255(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 22, 23, 24, 25, 26, 20, 19, 18, 17, 16, 14. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss C01 Truss Type Common Qty 2 Ply 1 TG184 RF B Job Reference (optional) I45169025 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:43 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-b_eutqfLpORz0vExAIkQdIN6KEOuviXkj588Ayzbk2o Scale = 1:35.7 1 2 3 4 5 6 7 4x6 4x6 5x9 1.5x4 1.5x4 4x6 10-0-0 10-0-0 20-0-0 10-0-0 5-0-0 5-0-0 10-0-0 5-0-0 15-0-0 5-0-0 20-0-0 5-0-0 21-0-0 1-0-0 0-6-05-6-00-6-06.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-1-1], [5:Edge,0-1-1], [7:0-4-8,0-3-4] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.35 0.61 0.28 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.14 -0.30 0.03 0.03 (loc) 7-13 7-10 5 7-10 l/defl >999 >806 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 70 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 5-8-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 5=0-3-8 Max Horz 1=-78(LC 17) Max Uplift 1=-57(LC 12), 5=-75(LC 13) Max Grav 1=838(LC 19), 5=900(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1426/131, 2-3=-1016/69, 3-4=-1014/70, 4-5=-1420/129 BOT CHORD 1-7=-128/1233, 5-7=-54/1225 WEBS 3-7=0/570, 4-7=-473/159, 2-7=-480/160 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss AE01 Truss Type GABLE Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169026 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:39 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-iDON2Scqm9xXYIxAxTgUTSDQPd27zuv8oTAx1Bzbk2s Scale = 1:54.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 44 43 42 41 40 39 38 37 36 35 34 33 31 30 29 28 27 26 25 50 51 52 53 5449 48 47 46 45 32 3x6 4x6 3x6 4x4 5x9 4x4 4x4 4x6 4x6 4x6 4x6 4x6 4x6 4x4 7-7-0 7-7-0 15-2-0 7-7-0 20-0-0 4-10-0 22-9-0 2-9-0 30-4-0 7-7-0 7-7-0 7-7-0 15-2-0 7-7-0 22-9-0 7-7-0 30-4-0 7-7-0 31-4-0 1-0-0 0-6-08-1-00-6-06.00 12 Plate Offsets (X,Y)-- [35:0-4-8,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.35 0.53 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.13 -0.20 0.03 0.08 (loc) 37 36-37 32 43-44 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 192 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-8-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 46, 48, 51, 53 REACTIONS.All bearings 10-7-8 except (jt=length) 1=0-3-8, 32=0-3-8. (lb) - Max Horz 1=-112(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 1, 29, 28, 27, 26, 25, 23, 32 except 31=-150(LC 20) Max Grav All reactions 250 lb or less at joint(s) 31, 30, 27, 26, 23, 23 except 1=893(LC 19), 29=576(LC 19), 28=260(LC 19), 25=262(LC 1), 32=600(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1456/94, 2-3=-1398/123, 3-4=-1373/137, 4-5=-1357/157, 5-6=-1299/157, 6-8=-687/53, 8-9=-630/69, 9-10=-611/87, 10-11=-607/111, 11-12=-561/122, 12-13=-558/131, 13-14=-612/128, 14-15=-605/111, 15-16=-613/102, 16-18=-596/84, 19-20=0/263, 20-21=0/251, 22-23=-31/268 BOT CHORD 1-44=-142/1241, 43-44=-142/1241, 42-43=-142/1241, 41-42=-142/1241, 40-41=-142/1241, 39-40=-142/1241, 38-39=-142/1241, 37-38=-142/1241, 36-37=-142/1241, 35-36=-142/1241 WEBS 35-50=-41/870, 50-51=-39/835, 51-52=-37/845, 52-53=-38/837, 53-54=-40/848, 18-54=-38/837, 18-29=-576/45, 6-49=-824/181, 48-49=-761/163, 47-48=-774/167, 46-47=-803/172, 45-46=-820/172, 35-45=-825/178, 6-40=-55/353 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 29, 28, 27, 26, 25, 23, 32, 23 except (jt=lb) 31=150. Continued on page 2 March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss AE01 Truss Type GABLE Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169026 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:39 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-iDON2Scqm9xXYIxAxTgUTSDQPd27zuv8oTAx1Bzbk2sNOTES- 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss A01 Truss Type Common Qty 11 Ply 1 TG184 RF B Job Reference (optional) I45169027 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:34 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-LGbU_lYhxdJFRX2C9v4JmOVSNcNIIdNPeCSALzzbk2x Scale = 1:52.8 1 2 3 4 5 6 7 8 11 10 9 18 193x8 MT18HS 5x6 3x8 MT18HS 4x6 5x9 4x4 1.5x4 4x4 1.5x4 4x6 7-7-0 7-7-0 15-2-0 7-7-0 22-9-0 7-7-0 30-4-0 7-7-0 7-7-0 7-7-0 15-2-0 7-7-0 22-9-0 7-7-0 30-4-0 7-7-0 31-4-0 1-0-0 0-6-08-1-00-6-06.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-0-13], [7:Edge,0-0-13], [10:0-4-8,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.82 0.45 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.09 -0.22 0.08 0.06 (loc) 9-10 9-10 7 11-14 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 112 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 3-4-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-10, 2-10 REACTIONS. (size)1=0-3-8, 7=0-3-8 Max Horz 1=-112(LC 13) Max Uplift 1=-87(LC 12), 7=-105(LC 13) Max Grav 1=1212(LC 1), 7=1274(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2140/153, 2-4=-1469/135, 4-6=-1469/135, 6-7=-2134/151 BOT CHORD 1-11=-162/1837, 10-11=-162/1837, 9-10=-55/1830, 7-9=-55/1830 WEBS 4-10=0/799, 6-10=-770/178, 6-9=0/299, 2-10=-777/180, 2-11=0/300 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 7=105. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss A02 Truss Type Common Qty 5 Ply 1 TG184 RF B Job Reference (optional) I45169028 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:35 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-qS9sC5ZJixR63hdOidbYIc2eg0jc10wYtsCjuQzbk2w Scale = 1:52.8 1 2 3 4 5 6 78 12 11 10 9 19 203x8 MT18HS 3x12 MT18HS 3x4 5x6 4x4 4x4 1.5x4 4x4 1.5x4 3x4 5x9 7-7-0 7-7-0 15-2-0 7-7-0 17-6-12 2-4-12 22-9-0 5-2-4 30-4-0 7-7-0 7-7-0 7-7-0 15-2-0 7-7-0 22-9-0 7-7-0 30-4-0 7-7-0 31-4-0 1-0-0 0-6-08-1-00-6-06.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-0-9], [5:0-4-9,0-1-8], [11:0-2-8,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.72 0.38 0.57 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.07 -0.16 0.02 0.05 (loc) 9-18 9-18 10 12-15 l/defl >999 >972 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 117 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-11, 4-10 REACTIONS. (size)1=0-3-8, 10=0-3-8, 7=0-3-8 Max Horz 1=-112(LC 13) Max Uplift 1=-64(LC 12), 10=-53(LC 12), 7=-86(LC 13) Max Grav 1=683(LC 19), 10=1345(LC 1), 7=517(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1041/105, 2-4=-277/107, 4-6=0/326, 6-7=-550/114 BOT CHORD 1-12=-120/860, 11-12=-120/860, 9-10=-22/424, 7-9=-22/424 WEBS 4-11=-6/493, 6-10=-749/171, 6-9=0/299, 2-11=-837/179, 2-12=0/332, 4-10=-987/65 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10, 7. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss A03 Truss Type Common Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169029 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:35 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-qS9sC5ZJixR63hdOidbYIc2eg0je10wYtsCjuQzbk2w Scale = 1:53.3 1 2 3 4 5 6 7 89 13 12 11 10 20 213x8 MT18HS 3x12 MT18HS 4x4 5x6 4x4 4x4 1.5x4 4x4 1.5x4 3x4 5x9 7-7-0 7-7-0 15-2-0 7-7-0 17-6-12 2-4-12 22-9-0 5-2-4 30-4-0 7-7-0 -1-0-0 1-0-0 7-7-0 7-7-0 15-2-0 7-7-0 22-9-0 7-7-0 30-4-0 7-7-0 31-4-0 1-0-0 0-6-08-1-00-6-06.00 12 Plate Offsets (X,Y)-- [6:0-4-9,0-1-8], [12:0-2-8,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.72 0.38 0.57 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.07 -0.16 0.02 0.05 (loc) 10-19 10-19 11 13-16 l/defl >999 >972 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 119 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-12, 5-11 REACTIONS. (size)2=0-3-8, 11=0-3-8, 8=0-3-8 Max Horz 2=106(LC 16) Max Uplift 2=-82(LC 12), 11=-54(LC 12), 8=-85(LC 13) Max Grav 2=742(LC 19), 11=1349(LC 1), 8=515(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1029/101, 3-5=-270/106, 5-7=0/330, 7-8=-546/113 BOT CHORD 2-13=-116/848, 12-13=-116/848, 10-11=-21/420, 8-10=-21/420 WEBS 5-12=-6/491, 7-11=-749/171, 7-10=0/299, 3-12=-830/177, 3-13=0/331, 5-11=-992/66 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11, 8. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss A04 Truss Type Common Qty 9 Ply 1 TG184 RF B Job Reference (optional) I45169030 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:36 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-IejEPQayTEZzhrCbGK6nrpbouP2lmXwi5VxHQszbk2v Scale = 1:53.3 1 2 3 4 5 6 7 89 12 11 10 19 203x8 MT18HS 5x6 3x8 MT18HS 4x6 5x9 4x4 1.5x4 4x4 1.5x4 4x6 7-7-0 7-7-0 15-2-0 7-7-0 22-9-0 7-7-0 30-4-0 7-7-0 -1-0-0 1-0-0 7-7-0 7-7-0 15-2-0 7-7-0 22-9-0 7-7-0 30-4-0 7-7-0 31-4-0 1-0-0 0-6-08-1-00-6-06.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-13], [8:Edge,0-0-13], [11:0-4-8,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.81 0.45 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.09 -0.22 0.08 0.05 (loc) 11-12 11-12 8 11 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 114 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 3-4-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-11, 3-11 REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-106(LC 13) Max Uplift 2=-104(LC 12), 8=-104(LC 13) Max Grav 2=1273(LC 1), 8=1273(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2133/150, 3-5=-1467/134, 5-7=-1467/134, 7-8=-2133/151 BOT CHORD 2-12=-160/1829, 11-12=-160/1829, 10-11=-55/1829, 8-10=-55/1829 WEBS 5-11=0/796, 7-11=-770/178, 7-10=0/299, 3-11=-770/177, 3-12=0/299 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=104, 8=104. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss M01 Truss Type Monopitch Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169031 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:52 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-qjhImvm_i9ahcIQfChPXVBFahsX?WdH2n?p7_xzbk2f Scale = 1:43.2 1 2 3 4 5 7 6 11 3x6 4x4 3x4 4x4 1.5x4 4x8 7-2-4 7-2-4 14-4-8 7-2-4 -1-0-0 1-0-0 7-2-4 7-2-4 14-4-8 7-2-4 0-6-07-8-47-4-120-3-87-8-46.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-9] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.63 0.35 0.88 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.06 -0.12 0.02 0.04 (loc) 6-7 6-7 6 7-10 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 57 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-1-8 Max Horz 2=231(LC 11) Max Uplift 2=-59(LC 12), 6=-98(LC 12) Max Grav 2=662(LC 19), 6=707(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-880/54, 5-6=-270/62 BOT CHORD 2-7=-92/720, 6-7=-92/720 WEBS 3-7=0/326, 3-6=-795/163 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss M02 Truss Type MONOPITCH Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169032 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:52 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-qjhImvm_i9ahcIQfChPXVBFafsXzWdA2n?p7_xzbk2f Scale = 1:43.2 1 2 3 4 6 5 10 3x6 4x4 3x4 4x4 1.5x4 4x8 7-2-4 7-2-4 14-4-8 7-2-4 7-2-4 7-2-4 14-4-8 7-2-4 0-6-07-8-47-4-120-3-87-8-46.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.63 0.35 0.89 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.06 -0.11 0.02 0.04 (loc) 5-6 5-6 5 6-9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 56 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 5=0-1-8 Max Horz 1=223(LC 11) Max Uplift 1=-41(LC 12), 5=-99(LC 12) Max Grav 1=600(LC 19), 5=709(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-886/56, 4-5=-270/62 BOT CHORD 1-6=-94/726, 5-6=-94/726 WEBS 2-6=0/327, 2-5=-802/165 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V1A Truss Type GABLE Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169033 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:55 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-EIMQPwps?4yGTl9EtqyE6qtDP4dfjBNVTz2nbFzbk2c Scale: 3/4"=1' 1 2 3 4 5 8 7 6 2x4 4x4 2x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 8-6-5 8-6-5 4-3-3 4-3-3 8-6-5 4-3-3 0-0-42-1-90-0-46.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.09 0.03 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-6-5. (lb) - Max Horz 1=24(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=261(LC 18), 6=261(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 8, 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V1B Truss Type Valley Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169034 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:55 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-EIMQPwps?4yGTl9EtqyE6qtEt4bAjBoVTz2nbFzbk2c Scale = 1:8.9 1 2 3 2x4 3x4 2x4 0-0-8 0-0-8 4-9-5 4-8-13 2-4-11 2-4-11 4-9-5 2-4-11 0-0-41-2-50-0-46.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.06 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-9-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-8-5, 3=4-8-5 Max Horz 1=12(LC 16) Max Uplift 1=-10(LC 12), 3=-10(LC 13) Max Grav 1=155(LC 18), 3=155(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V1C Truss Type Valley Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169035 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:56 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-iUwocGpUlO474vkRRXTTf1QK8TyZSeceidnK7izbk2b Scale = 1:16.2 1 2 3 4 2x4 4x4 2x4 1.5x4 0-0-8 0-0-8 8-9-5 8-8-13 4-4-11 4-4-11 8-9-5 4-4-11 0-0-42-2-50-0-46.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.35 0.12 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-8-5, 3=8-8-5, 4=8-8-5 Max Horz 1=-25(LC 13) Max Uplift 1=-26(LC 12), 3=-30(LC 13) Max Grav 1=207(LC 18), 3=207(LC 19), 4=300(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V1D Truss Type Valley Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169036 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:56 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-iUwocGpUlO474vkRRXTTf1QHeTvTSe7eidnK7izbk2b Scale = 1:21.6 1 2 3 4 5 6 4x6 4x6 4x6 1.5x4 0-0-8 0-0-8 12-9-5 12-8-13 6-4-11 6-4-11 12-9-5 6-4-11 0-0-43-2-50-0-46.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.57 0.32 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=12-8-5, 3=12-8-5, 4=12-8-5 Max Horz 1=38(LC 12) Max Uplift 1=-28(LC 12), 3=-35(LC 13), 4=-11(LC 12) Max Grav 1=281(LC 18), 3=281(LC 19), 4=526(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-330/68 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V1E Truss Type Valley Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169037 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:57 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-AhUBpcq7WhC_i3Jd?F_iBFyWBtI4B5QnxHXuf8zbk2a Scale = 1:29.9 1 2 3 4 5 9 8 7 6 10 11 3x4 4x4 3x4 3x6 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 16-8-13 16-8-13 16-9-5 0-0-8 8-4-11 8-4-11 16-9-5 8-4-11 0-0-44-2-50-0-46.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.26 0.10 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 47 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-8-5. (lb) - Max Horz 1=-51(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=278(LC 19), 9=482(LC 18), 6=482(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-387/128, 4-6=-387/128 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 9, 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V1F Truss Type Valley Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169038 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:58 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-ft2Z1yrlH?KrKDupZyWxkSVfsHbuwXFx9xGRCazbk2Z Scale = 1:37.3 1 2 3 4 5 9 8 7 6 10 11 12 133x4 4x4 3x4 3x6 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 0-0-8 0-0-8 20-9-5 20-8-13 10-4-11 10-4-11 20-9-5 10-4-11 0-0-45-2-50-0-46.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.40 0.26 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 60 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 20-8-5. (lb) - Max Horz 1=64(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 9=-110(LC 12), 6=-110(LC 13) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=280(LC 4), 9=614(LC 3), 6=614(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-463/162, 4-6=-463/162 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 9=110, 6=110. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V1G Truss Type Valley Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169039 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:59 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-73cxEIsN2JSixNT06g1AHg2tnh_Ff_p4Ob0?k1zbk2Y Scale = 1:41.7 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 3x4 4x4 3x4 3x6 0-0-8 0-0-8 24-9-5 24-8-13 12-4-11 12-4-11 24-9-5 12-4-11 0-0-46-2-50-0-46.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.19 0.12 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E *Except* 1-11: 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 24-8-5. (lb) - Max Horz 1=77(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1, 12, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=383(LC 3), 12=463(LC 3), 13=365(LC 2), 9=463(LC 4), 8=365(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-12=-372/127, 5-9=-372/126 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 12, 13, 9, 8. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V1H Truss Type Valley Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169040 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:45:00 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-bGAJSet?pcaZZX1CgNYPpta1V5I6OQCEdElYGTzbk2X Scale: 1/4"=1' 1 2 3 4 5 6 7 13 12 1110 9 8 14 15 16 173x4 4x4 3x4 3x6 0-0-8 0-0-8 28-9-5 28-8-13 14-4-11 14-4-11 28-9-5 14-4-11 0-0-47-2-50-0-46.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.26 0.21 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 92 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 28-8-5. (lb) - Max Horz 1=90(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 12, 9 except 13=-102(LC 12), 8=-102(LC 13) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=402(LC 24), 12=438(LC 3), 13=510(LC 2), 9=438(LC 4), 8=510(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-12=-341/114, 2-13=-332/152, 5-9=-341/114, 6-8=-332/152 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 12, 9 except (jt=lb) 13=102, 8=102. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V1I Truss Type Valley Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169041 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:45:01 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-3Sjhf_tdawiQBgcOE43eM57DQUeM7sjNruV5ovzbk2W Scale = 1:54.3 1 2 3 4 5 6 7 8 9 10 11 20 19 1817 16 1514 13 12 21 223x6 4x4 3x6 3x4 3x6 3x4 3x6 0-0-8 0-0-8 32-9-5 32-8-13 16-4-11 16-4-11 32-9-5 16-4-11 0-0-48-2-50-0-46.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.25 0.14 0.23 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 111 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 32-8-5. (lb) - Max Horz 1=103(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1, 17, 19, 20, 15, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 1, 11 except 16=385(LC 24), 17=508(LC 3), 19=359(LC 2), 20=369(LC 3), 15=508(LC 4), 13=359(LC 2), 12=369(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-17=-375/126, 2-20=-254/119, 7-15=-375/126, 10-12=-254/119 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 17, 19, 20, 15, 13, 12. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V1J Truss Type GABLE Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169042 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:45:03 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-?rrS4fvt6Xy8Q_mnLV56RWCa6ILvbnfgJC_Ctozbk2U Scale = 1:57.8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 3x6 4x4 3x6 3x4 5x6 5x6 3x4 34-10-5 34-10-5 17-5-3 17-5-3 34-10-5 17-5-3 0-0-48-8-90-0-46.00 12 Plate Offsets (X,Y)-- [32:0-3-0,0-3-0], [40:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.11 0.07 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 25 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 194 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 13-36 REACTIONS.All bearings 34-10-5. (lb) - Max Horz 1=110(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26 Max Grav All reactions 250 lb or less at joint(s) 1, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 35, 34, 33, 32, 31, 30, 29, 28, 27, 25 except 46=292(LC 18), 26=292(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss ME01 Truss Type GABLE Qty 3 Ply 1 TG184 RF B Job Reference (optional) I45169043 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:54 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-m6o2BaoEEmqPrca2K6R?acK2TgHR_k9LEJIE3pzbk2d Scale = 1:17.8 1 2 3 4 5 8 7 6 1.5x4 1.5x4 2x4 1.5x4 1.5x4 1.5x4 1.5x4 -1-0-0 1-0-0 5-0-0 5-0-0 0-6-03-0-06.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.10 0.03 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-0-0. (lb) - Max Horz 2=85(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 6, 2, 7, 8 Max Grav All reactions 250 lb or less at joint(s) 6, 2, 7, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 2, 7, 8. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss M03 Truss Type Monopitch Qty 14 Ply 1 TG184 RF B Job Reference (optional) I45169044 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:53 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-IwEg_FncTTiYDS?smPwm1Poo2GvHFHjC0fZgWNzbk2e Scale = 1:17.5 1 2 3 5 4 6 7 8 3x4 1.5x4 3x4 4x4 3x4 5-0-0 5-0-0 -1-0-0 1-0-0 5-0-0 5-0-0 0-3-150-5-33-5-30-2-12-6-70-5-93-5-36.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-12] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MR 0.40 0.22 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.03 -0.06 0.13 0.01 (loc) 4-5 4-5 7 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-1-12, 7=0-1-8 Max Horz 2=70(LC 12) Max Uplift 2=-34(LC 12), 7=-31(LC 12) Max Grav 2=381(LC 19), 7=209(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 7. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 7. 10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V3B Truss Type Valley Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169045 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:45:07 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-uc5yw1yOAmTZvb4YaLA2bMNGEvj8XdWGEqyQ0Zzbk2Q Scale = 1:14.7 1 2 3 4 2x4 4x4 2x4 1.5x4 0-0-6 0-0-6 6-0-0 5-11-10 3-0-0 3-0-0 6-0-0 3-0-0 0-0-42-0-00-0-48.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.10 0.05 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-11-4, 3=5-11-4, 4=5-11-4 Max Horz 1=-32(LC 8) Max Uplift 1=-18(LC 10), 3=-22(LC 11) Max Grav 1=108(LC 1), 3=108(LC 1), 4=187(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V3A Truss Type Valley Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169046 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:45:06 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-QQXaihxmPSLiHSVM1efp38q6pVO7oAW6?ACsU7zbk2R Scale = 1:7.7 1 2 3 2x4 3x4 2x4 0-0-6 0-0-6 3-0-0 2-11-10 1-6-0 1-6-0 3-0-0 1-6-0 0-0-41-0-00-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.01 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-11-4, 3=2-11-4 Max Horz 1=13(LC 9) Max Uplift 1=-5(LC 10), 3=-5(LC 11) Max Grav 1=81(LC 1), 3=81(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss BE01 Truss Type GABLE Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169047 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:41 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-ecW7T8e4InBFnc4Y3uiyYtIq9QrKRrHRFnf253zbk2q Scale = 1:43.1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 4x4 3x4 5x6 3x4 23-6-8 23-6-8 -1-0-0 1-0-0 11-9-4 11-9-4 23-6-8 11-9-4 24-6-8 1-0-0 0-6-06-4-100-6-06.00 12 Plate Offsets (X,Y)-- [27:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.08 0.04 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 18 18 18 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 117 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 23-6-8. (lb) - Max Horz 2=83(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 2, 28, 29, 30, 31, 32, 33, 34, 26, 25, 24, 23, 22, 21, 20, 18 Max Grav All reactions 250 lb or less at joint(s) 2, 27, 28, 29, 30, 31, 32, 33, 34, 26, 25, 24, 23, 22, 21, 20, 18 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 28, 29, 30, 31, 32, 33, 34, 26, 25, 24, 23, 22, 21, 20, 18. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss B01 Truss Type Common Qty 7 Ply 1 TG184 RF B Job Reference (optional) I45169048 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:40 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-APylFodSXT3O9SWMVABj?flYP1PsiNSH07vUZdzbk2r Scale = 1:41.7 1 2 3 4 5 6 7 10 9 8 17 18 19 20 4x6 3x6 4x4 4x6 1.5x4 4x4 1.5x4 4x6 7-10-3 7-10-3 15-8-5 7-10-2 23-6-8 7-10-3 -1-0-0 1-0-0 5-10-10 5-10-10 11-9-4 5-10-10 17-7-14 5-10-10 23-6-8 5-10-10 24-6-8 1-0-0 0-6-06-4-100-6-06.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.52 0.50 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.15 -0.25 0.04 0.04 (loc) 8-10 8-10 6 8-10 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 85 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 5-0-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=83(LC 12) Max Uplift 2=-85(LC 12), 6=-85(LC 13) Max Grav 2=1088(LC 3), 6=1088(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1769/129, 3-4=-1603/131, 4-5=-1603/132, 5-6=-1769/129 BOT CHORD 2-10=-133/1533, 8-10=-12/993, 6-8=-50/1533 WEBS 4-8=-54/688, 5-8=-415/166, 4-10=-54/688, 3-10=-415/166 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss BE2 Truss Type GABLE Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169049 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:42 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-6o4WgUfi24J6PmfkdbDB54rzGq21AGFaURObdWzbk2p Scale = 1:43.5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 18 17 16 15 19 20 21 22 23 24 25 26 33 4x6 4x4 3x6 3x4 4x4 5x6 4x6 4x8 9-10-8 9-10-8 15-7-6 5-8-14 19-9-0 4-1-10 23-6-8 3-9-8 4-11-4 4-11-4 9-10-8 4-11-4 11-9-4 1-10-12 17-6-7 5-9-3 23-6-8 6-0-1 24-6-8 1-0-0 0-6-06-4-100-6-06.00 12 Plate Offsets (X,Y)-- [16:0-3-0,0-1-12] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.25 0.58 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.14 -0.29 0.03 0.02 (loc) 18-29 18-29 30 18-29 l/defl >999 >818 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 106 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 5-10-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 19, 22, 24 REACTIONS.All bearings 4-1-0 except (jt=length) 1=0-3-8. (lb) - Max Horz 1=-90(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 1, 16 except 15=-172(LC 5) Max Grav All reactions 250 lb or less at joint(s) except 1=839(LC 19), 13=292(LC 20), 16=960(LC 20), 16=949(LC 1), 13=261(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1416/138, 2-3=-1068/68, 6-7=-263/28, 9-10=-254/0, 10-11=-264/0, 12-13=-255/9 BOT CHORD 1-18=-145/1220, 16-18=-59/1037 WEBS 3-20=-894/120, 19-20=-853/103, 19-21=-845/104, 21-22=-855/107, 22-26=-872/118, 23-26=-916/149, 23-24=-952/157, 24-25=-970/161, 16-25=-1002/167, 3-18=0/497, 2-18=-380/148, 18-26=-342/136 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 16 except (jt=lb) 15=172. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss EG01 Truss Type Common Girder Qty 1 Ply 2 TG184 RF B Job Reference (optional) I45169050 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:51 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-MX7vZZmMxrSr_8rTe_uIy_iWiSC8nJIvYL4aSUzbk2g Scale = 1:36.0 1 2 3 4 5 7 614151617 18 19 6x6 6x6 6x6 4x6 1.5x4 6x6 1.5x4 JUS26 JUS26 JUS26 JUS26 JUS26 JUS26 JUS26 4-10-11 4-10-11 9-9-5 4-10-10 14-8-0 4-10-11 3-8-0 3-8-0 7-4-0 3-8-0 11-0-0 3-8-0 14-8-0 3-8-0 0-8-05-6-110-8-08.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-2-6], [5:0-0-0,0-2-6], [6:0-3-0,0-4-0], [7:0-3-0,0-4-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.14 0.26 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.05 -0.09 0.01 0.03 (loc) 6-7 6-7 5 6-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 149 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP DSS WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 5=0-3-8 Max Horz 1=-95(LC 26) Max Uplift 1=-310(LC 10), 5=-266(LC 11) Max Grav 1=3773(LC 1), 5=3057(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-4222/365, 2-3=-4115/398, 3-4=-4104/408, 4-5=-4212/376 BOT CHORD 1-7=-324/3451, 6-7=-176/2379, 5-6=-273/3441 WEBS 3-6=-251/2343, 3-7=-231/2363 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=310, 5=266. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Use USP JUS26 (With 4-10d nails into Girder & 4-10d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 0-5-4 from the left end to 12-5-4 to connect truss(es) to front face of bottom chord. 10) Fill all nail holes where hanger is in contact with lumber. LOAD CASE(S) Standard Continued on page 2 March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss EG01 Truss Type Common Girder Qty 1 Ply 2 TG184 RF B Job Reference (optional) I45169050 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:51 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-MX7vZZmMxrSr_8rTe_uIy_iWiSC8nJIvYL4aSUzbk2g LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 8-11=-20 Concentrated Loads (lb) Vert: 10=-813(F) 14=-807(F) 15=-807(F) 16=-803(F) 17=-803(F) 18=-811(F) 19=-811(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss EE01 Truss Type GABLE Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169051 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:50 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-tLZXLDlkAYK_M_HH5HM3PmAMS3wj2wrlKhK0w2zbk2h Scale = 1:34.7 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 3x6 4x4 3x6 14-8-0 14-8-0 -1-0-0 1-0-0 7-4-0 7-4-0 14-8-0 7-4-0 15-8-0 1-0-0 0-8-05-6-110-8-08.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.10 0.02 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 12 12 14 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 72 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 14-8-0. (lb) - Max Horz 24=-120(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V3C Truss Type GABLE Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169052 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:45:08 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-MoeL7Nz0x3bQWlfk82hH8ZwS_J3tG3nPSUhzY?zbk2P Scale = 1:16.9 1 2 3 4 5 8 7 6 2x4 4x4 2x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 7-3-12 7-3-12 3-7-14 3-7-14 7-3-12 3-7-14 0-0-42-5-40-0-48.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.04 0.02 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 7-3-12. (lb) - Max Horz 1=-41(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 1, 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7, 8, 6 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V2A Truss Type Valley Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169053 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:45:04 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-T1PqH?wWtr5_28LzvDcL_jlmFiiPKG1pYsjmPEzbk2T Scale = 1:8.3 1 2 3 2x4 3x4 2x4 0-0-6 0-0-6 3-4-4 3-3-14 1-8-2 1-8-2 3-4-4 1-8-2 0-0-41-1-70-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.02 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 3-4-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-3-8, 3=3-3-8 Max Horz 1=-15(LC 6) Max Uplift 1=-6(LC 10), 3=-6(LC 11) Max Grav 1=96(LC 1), 3=96(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V2B Truss Type Valley Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169054 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:45:05 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-xDzCVLw8e9DrfIw9Tw8aWxIwU62Y3j_zmWTJxgzbk2S Scale = 1:15.3 1 2 3 4 2x4 4x4 2x4 1.5x4 0-0-6 0-0-6 6-4-4 6-3-14 3-2-2 3-2-2 6-4-4 3-2-2 0-0-42-1-70-0-48.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.12 0.06 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-3-8, 3=6-3-8, 4=6-3-8 Max Horz 1=35(LC 7) Max Uplift 1=-19(LC 10), 3=-24(LC 11) Max Grav 1=115(LC 1), 3=115(LC 1), 4=200(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V2C Truss Type Valley Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169055 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:45:05 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-xDzCVLw8e9DrfIw9Tw8aWxItb60B3jjzmWTJxgzbk2S Scale = 1:20.7 1 2 3 42x4 4x4 2x4 1.5x4 9-3-14 9-3-14 9-4-4 0-0-6 4-8-2 4-8-2 9-4-4 4-8-2 0-0-43-1-70-0-48.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.30 0.15 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=9-3-8, 3=9-3-8, 4=9-3-8 Max Horz 1=54(LC 9) Max Uplift 1=-30(LC 10), 3=-37(LC 11) Max Grav 1=180(LC 1), 3=180(LC 1), 4=312(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss V2D Truss Type Valley Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169056 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:45:06 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-QQXaihxmPSLiHSVM1efp38q1rVLOo9M6?ACsU7zbk2R Scale = 1:25.8 1 2 3 44x4 4x6 4x4 1.5x4 0-0-6 0-0-6 12-4-4 12-3-14 6-2-2 6-2-2 12-4-4 6-2-2 0-0-44-1-70-0-48.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.33 0.22 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=12-3-8, 3=12-3-8, 4=12-3-8 Max Horz 1=73(LC 7) Max Uplift 1=-26(LC 10), 3=-35(LC 11), 4=-7(LC 10) Max Grav 1=217(LC 1), 3=217(LC 1), 4=477(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-282/58 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss DE01 Truss Type GABLE Qty 1 Ply 1 TG184 RF B Job Reference (optional) I45169057 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:49 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-P8?98tk5PEC7lqi5XZrqtZdB8fa?JUbc51bTNczbk2i Scale = 1:36.1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 25 24 23 22 21 20 19 18 17 16 153x4 4x4 5x6 3x4 19-9-0 19-9-0 9-10-8 9-10-8 19-9-0 9-10-8 20-9-0 1-0-0 0-6-05-5-40-6-06.00 12 Plate Offsets (X,Y)-- [20:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.08 0.05 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 13 14 13 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 88 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 19-9-0. (lb) - Max Horz 1=-75(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 1, 21, 22, 23, 24, 25, 19, 18, 17, 16, 15, 13 Max Grav All reactions 250 lb or less at joint(s) 1, 20, 21, 22, 23, 24, 19, 18, 17, 16, 15, 13 except 25=265(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 21, 22, 23, 24, 25, 19, 18, 17, 16, 15, 13. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss D1 Truss Type Roof Special Qty 2 Ply 1 TG184 RF B Job Reference (optional) I45169058 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:46 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:8JTHMmKHy8cy9hJNfHm90rzc227-?ZJ0WriD6JpYtNzWsRI7Fw?YlRS66_RAP3MpmHzbk2l Scale = 1:37.6 1 2 3 4 5 7 6 11 10 9 15 16 8 5x6 4x6 3x4 6x8 1.5x4 4x8 5x6 6x10 5x9 8x8 7-10-117-10-11 9-10-81-11-13 14-4-54-5-13 14-6-50-2-0 15-6-8 1-0-3 19-1-33-6-11 4-11-44-11-4 9-10-84-11-4 14-4-54-5-13 14-6-50-2-0 15-6-8 1-0-3 16-11-51-4-13 19-1-32-1-14 19-9-00-7-13 20-1-3 0-4-3 0-6-01-5-45-5-40-2-81-1-126.00 12 Plate Offsets (X,Y)-- [4:0-4-7,0-2-8], [6:0-6-8,Edge], [7:0-7-13,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.66 0.51 0.58 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.18 -0.38 -0.16 0.08 (loc) 11-14 11-14 1 9 l/defl >999 >614 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 85 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E *Except* 3-5: 2x4 SP DSS, 5-8: 2x8 SP DSS BOT CHORD 2x4 SPF 1650F 1.5E *Except* 5-9: 2x4 SP DSS WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 3-8-8 oc purlins, except 2-0-0 oc purlins (10-0-0 max.): 6-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=Mechanical, 8=0-3-8 Max Horz 8=68(LC 16) Max Uplift 1=-67(LC 12), 8=-147(LC 13) Max Grav 1=831(LC 19), 8=1133(LC 33) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1410/157, 2-3=-1043/104, 3-4=-1117/101, 4-5=-3040/368, 5-7=-3112/354, 7-8=-496/100, 6-7=-404/3235 BOT CHORD 1-11=-92/1220, 10-11=-167/1455, 9-10=-34/306, 5-6=-953/150 WEBS 2-11=-477/154, 3-11=-13/626, 4-11=-671/174, 6-10=-184/1600, 4-6=-311/2381, 4-10=-1144/135 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=147. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss D2 Truss Type Roof Special Qty 2 Ply 1 TG184 RF B Job Reference (optional) I45169059 8.430 s Dec 17 2020 MiTek Industries, Inc. Fri Mar 12 11:47:25 2021 Page 1 84 Lumber-0783, Franklin, Indiana ID:8JTHMmKHy8cy9hJNfHm90rzc227-Kjl0l181Sqf9v4ZuhIQatNVbPGKJof77EfcjHwzbgVG Scale = 1:34.7 1 2 3 4 8 7 6 12 5 4x6 6x8 3x6 3x4 8x12 MT18HS 4x8 1.5x4 8-5-7 8-5-7 9-10-8 1-5-1 16-8-0 6-9-8 19-1-3 2-5-3 4-11-44-11-4 9-10-84-11-4 16-8-06-9-8 19-1-32-5-3 19-9-00-7-13 20-1-3 0-4-3 0-6-05-5-40-2-86.00 12 Plate Offsets (X,Y)-- [4:0-3-8,0-1-12] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.55 0.89 0.24 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.22 -0.39 0.24 0.12 (loc) 6 6 5 6 l/defl >999 >609 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 88 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E *Except* 3-5: 2x8 SP DSS BOT CHORD 2x4 SPF 1650F 1.5E *Except* 4-6: 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-10-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-3-12 oc bracing. REACTIONS.(lb/size)1=779/Mechanical, 5=727/0-3-8 Max Horz 1=-68(LC 13) Max Uplift 1=-59(LC 12), 5=-89(LC 13) Max Grav 1=818(LC 19), 5=766(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1380/136, 2-3=-1005/77, 3-12=-837/77, 4-12=-877/57, 4-5=-334/51 BOT CHORD 1-8=-136/1191, 7-8=-21/319, 6-7=-21/319 WEBS 2-8=-440/150, 4-8=-2/569, 3-8=0/343 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 59 lb uplift at joint 1 and 89 lb uplift at joint 5. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard March 12,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 23598-23598A Truss D3 Truss Type Common Qty 3 Ply 1 TG184 RF B Job Reference (optional) I45169060 8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Mar 12 07:44:47 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:f2jJdMYGnan1KdABAa0FhpzcNoy-TmtPjBirtdxPVXYiP8pMo8YnQrm4rWgJdj6MJjzbk2k Scale = 1:35.3 1 2 3 4 5 6 7 4x6 4x6 5x9 1.5x4 1.5x4 4x6 9-10-8 9-10-8 19-9-0 9-10-8 4-11-4 4-11-4 9-10-8 4-11-4 14-9-12 4-11-4 19-9-0 4-11-4 20-9-0 1-0-0 0-6-05-5-40-6-06.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-1-1], [5:Edge,0-1-1], [7:0-4-8,0-3-4] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.35 0.59 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.14 -0.28 0.03 0.02 (loc) 7-13 7-10 5 7-10 l/defl >999 >837 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 69 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 5-9-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=Mechanical, 5=0-3-8 Max Horz 1=-77(LC 17) Max Uplift 1=-56(LC 12), 5=-74(LC 13) Max Grav 1=827(LC 19), 5=890(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1407/130, 2-3=-1003/68, 3-4=-1001/69, 4-5=-1401/128 BOT CHORD 1-7=-127/1216, 5-7=-53/1208 WEBS 3-7=0/562, 4-7=-466/156, 2-7=-473/158 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 12,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths