Loading...
HomeMy WebLinkAboutA10602 WB1 01 WB1 01 WB1 02 WB1 02 WB1 02 WB1 02 WB1 02 WB1 04 WB1 03 WB1 02 WB1 GARAGE DRYWALL NOTE: ALL GARAGE WALLS, CEILING, BEAMS, COLUMNS AND WALLS THAT SUPPORT FLOOR-CEILING ASSEMBLY ABOVE TO HAVE 12" DRYWALL (FINISHED). CEILING TO BE 58" TYPE "X" FIRECODE DRYWALL BELOW HABITABLE SPACES. 02 WB1 02 WB1 02 WB1 02 WB1 WILLIAML.KAU FH O L Z A RCHITECT12" GYPSUM BOARD (UNBLOCKED) - FASTEN 7"o.c. ON PERIMETER (EXCEPT AT UNBLOCKED HORIZONTAL SEAMS) AND FIELD - FASTENERS TO BE TYPE "W" OR "S" 114" LONG SCREWS OR 112" LONG 38" HEAD .120" DRYWALL NAILS 2x FRAME WALL NOTES: COMPLIANCE METHOD: THIS STRUCTURE HAS BEEN DESIGNED IN COMPLIANCE WITH SECTIONS R301.1.1 and R602.10, ENGINEERED WALL SYSTEM. THIS DRAWING ILLUSTRATES AN ENGINEERED DESIGN APPROACH AND IS BASED ON STRUCTURAL ENGINEERING CALCULATIONS SPECIFIC TO THIS DESIGN. WALL LOAD CAPACITY: THERMO-SHEATH (BLUE) VALUES PROVIDED BY DrJ EVALUATION REPORT TER No. 1310-03. DRYLINE TSX (BLUE) VALUES PROVIDED BY DrJ EVALUATION REPORT TER No. 1407-07. WALL WIND LOADS CALCULATED USING A 115MPH ULTIMATE DESIGN WIND SPEED, EXPOSURE B. PLAN DETAIL - OUTSIDE FRAMED CORNER SCALE:07 2x FRAME WALL (REAR OR FRONT WALL) 2x FRAME WALL (SIDE WALL) 412" PIECE OF .135" THERMO-SHEATH EXTERIOR SHEATHING (BLUE) LAPPED OVER UNSHEATHED END OF REAR/ FRONT WALL AND SIDE WALL - FASTEN 3"o.c. TO END STUDS - FASTENERS TO BE 1" CROWN x 114" LEG STAPLES (16 GAUGE)SIDE WALL FRONT OR BACK WALL SECTION DETAIL - GYP BOARD / GYP BOARD SCALE:03 TOP PLATE 2x FRAME WALL SECTION DETAIL - THERMO-SHEATH SCALE: 3" = 1'-0"01 TOP PLATE EXTERIOR STRUCTURAL SHEATHING - FASTEN 3"o.c. ON PERIMETER AND IN FIELD - FASTENERS TO BE 1" CROWN x 114" LEG STAPLES (16 GAUGE) GYP BOARD / THERMO-SHEATH / GYP BOARD SCALE:04 TOP PLATE 2x FRAME WALL GYP BOARD / THERMO-SHEATH SCALE:02 TOP PLATE SECTION DETAIL - 12" GYPSUM BOARD (UNBLOCKED) - FASTENERS TO BE #6 x 114" LONG TYPE "W" DRYWALL SCREWS FASTENED 6"o.c. AROUND PERIMETER (EXCEPT AT UNBLOCKED HORIZONTAL SEAMS) AND 12"o.c. IN FIELD OR 112" LONG 38" HEAD .120" DRYWALL NAILS FASTENED 6"o.c. AROUND PERIMETER (EXCEPT AT UNBLOCKED HORIZONTAL SEAMS) AND 7"o.c. IN FIELD 2x FRAME WALL 3" = 1'-0" 3" = 1'-0" 3" = 1'-0" 3" = 1'-0" 12" GYPSUM BOARD (UNBLOCKED) - FASTEN 7"o.c. ON PERIMETER (EXCEPT AT UNBLOCKED HORIZONTAL SEAMS) AND FIELD - FASTENERS TO BE TYPE "W" OR "S" 11 4" LONG SCREWS OR 112" LONG 38" HEAD .120" DRYWALL NAILS 12" GYPSUM BOARD (UNBLOCKED) - FASTENERS TO BE #6 x 114" LONG TYPE "W" DRYWALL SCREWS FASTENED 6"o.c. AROUND PERIMETER (EXCEPT AT UNBLOCKED HORIZONTAL SEAMS) AND 12"o.c. IN FIELD OR 112" LONG 38" HEAD .120" DRYWALL NAILS FASTENED 6"o.c. AROUND PERIMETER AND 7"o.c. IN FIELD (1) ROW 16d @ 12"o.c. REAR OF GARAGE SHEAR TRANSFER SCALE: 3" = 1'-0" 09 EXTERIOR PLAN DETAIL - SIDE WALL / GARAGE END NAIL REAR OF GARAGE WALL STUD w/ (2) 16d NAILS @ 6" o.c. STUD WALL @ REAR OF GARAGE - 2x4 STUD WALL @ 16"o.c. - HEIGHT PER PLAN STUD WALL @ SIDE OF HOUSE 12" GYPSUM BOARD (UNBLOCKED) - FASTEN 7"o.c. ON PERIMETER (EXCEPT AT UNBLOCKED HORIZONTAL SEAMS) AND FIELD - FASTENERS TO BE TYPE "W" OR 112" LONG 38" HEAD .120" DRYWALL NAILS INTERIOR REAR OF GARAGE SHEAR TRANSFER SCALE: 3" = 1'-0"08 EXTERIOR PLAN DETAIL - SIDE WALL / GARAGE END NAIL REAR OF GARAGE WALL INTO 2x FRAMING W/ (2) 16d @ 6"o.c. STUD WALL @ REAR OF GARAGE - 2x4 STUD WALL @ 16"o.c. - HEIGHT PER PLAN 2x4 STUD @ WALL INTERSECTION FOR SHEAR TRANSFER - FASTEN W/ (2) 16d NAILS @ 6"o.C. END NAIL THROUGH STUDS INTO FRAMING W/ 16d @ 6"o.c. STUD WALL @ SIDE OF HOUSE 12" GYPSUM BOARD (UNBLOCKED) - FASTEN 7"o.c. ON PERIMETER (EXCEPT AT UNBLOCKED HORIZONTAL SEAMS) AND FIELD - FASTENERS TO BE TYPE "W" OR 112" LONG 38" HEAD .120" DRYWALL NAILS 12" GYPSUM BOARD (UNBLOCKED) - FASTEN 7"o.c. ON PERIMETER (EXCEPT AT UNBLOCKED HORIZONTAL SEAMS) AND FIELD - FASTENERS TO BE TYPE "W" OR "S" 11 4" LONG SCREWS OR 112" LONG 38" HEAD .120" DRYWALL NAILS 2x FRAME WALL SECTION DETAIL - GYP BOARD / GYP BOARD SCALE:05 TOP PLATE GYP BOARD / THERMO-SHEATH / GYP BOARD SCALE: 06 TOP PLATE SECTION DETAIL - 2x FRAME WALL 3" = 1'-0" 3" = 1'-0" 12" GYPSUM BOARD (UNBLOCKED) - FASTEN 7"o.c. ON PERIMETER (EXCEPT AT UNBLOCKED HORIZONTAL SEAMS) AND FIELD - FASTENERS TO BE TYPE "W" OR "S" 114" LONG SCREWS OR 112" LONG 38" HEAD .120" DRYWALL NAILS INTERIOR INTERIOR GARAGE EXTERIOR CONTINUOUS FOIL FACE TAPE EXTERIOR STRUCTURAL SHEATHING - FASTEN 3"o.c. ON PERIMETER AND IN FIELD - FASTENERS TO BE 1" CROWN x 114" LEG STAPLES (16 GAUGE) EXTERIOR GARAGE EXTERIOR STRUCTURAL SHEATHING - FASTEN 3"o.c. ON PERIMETER AND IN FIELD - FASTENERS TO BE 1" CROWN x 114" LEG STAPLES (16 GAUGE) GARAGE INTERIOR GARAGE INTERIOR EXTERIOR STRUCTURAL SHEATHING - FASTEN 3"o.c. ON PERIMETER AND IN FIELD - FASTENERS TO BE 1" CROWN x 114" LEG STAPLES (16 GAUGE) GARAGE INTERIOR EXTERIOR STRUCTURAL SHEATHING - FASTEN 3"o.c. ON PERIMETER AND IN FIELD - FASTENERS TO BE 1" CROWN x 114" LEG STAPLES (16 GAUGE) EXTERIOR STRUCTURAL SHEATHING - FASTEN 3"o.c. ON PERIMETER AND IN FIELD - FASTENERS TO BE 1" CROWN x 114" LEG STAPLES (16 GAUGE) EXTERIOR STRUCTURAL SHEATHING - FASTEN 3"o.c. ON PERIMETER AND IN FIELD - FASTENERS TO BE 1" CROWN x 114" LEG STAPLES (16 GAUGE) INTERIOR INTERIOR SECTION DETAIL -OVERBROOK FARMSREASON FOR PLOT: PLOT DATE:Job No. Sheet No.IN HOMESITE NO.OFFICE REVIEW:MASTER BY: DATE: C DATE: 3940 OLYMPIC BLVD ERLANGER, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVEDFISCHER HOMES, Inc.JOB INFO:DATE: PERMIT: SIGN-OFF: CONSTRUCTION:REVISION:REVISION:REVISION:REVISION:HOME TYPE:PLAN:2/25/2021 10:54 AM# OBF011000000VIJAYALAKSHMI CUTTAMANCHI3965 BEAR CREEK WAYCLAY46-430-CLAY FRENCH MANOR WITH BRICKCARMEL, IN10005/2017JP------------------------------------------------fieldspecchange@fischerhomes.comREVISED BY:----KIRANKUMAR MANUBOLUSAPPHIRE TRADE SUPPORTsapphiretradepartners@fischerhomes.comFischer Homes Indianapolis II, LLCWB1 SCALE = 1'-0" FIRST FLOOR WALL BRACING 1/8"11 SCALE = 1'-0" SECOND FLOOR WALL BRACING 1/8"10 04/01/21