HomeMy WebLinkAboutA125BRICK VENEER @ BAND BOARD SCALE: 3" = 1'-0"2"(MIN.)BRICK VENEER - 24" O.C. VERT. (9 COURSES) - 16" O.C. HORIZONTAL METAL WALL TIES STRUCTURAL SHEATHING DOUBLE 2x4 TOP PLATE STRUCTURAL SHEATHING AIR SPACE, TYPICAL @ SECOND FLOOR NOTE: SECOND FLR STRUCTURAL SHT'G TO OVERLAP FIRST FLR STRUCTURAL SHT'G 2" MINIMUM @ FIRST FLOOR SECTION DETAIL 8" @ 2x10's6" @ 2x12'sHOLD T/POLY FLASH'G AT: 8" OFF T/SUBFLOOR FOR 2x10 JSTS 6" OFF T/SUBFLOOR FOR 2x12 JSTS APPROVED FASTENER @ 12"o.c. IN BTM 1/3 OF BAND BD APPROVED FASTENER @ 3"o.c., TYPICAL APPROVED FASTENER @ 3"o.c., TYPICAL 24" POLY FLASHING @ SECOND FLR BAND BD - EXTEND PAST BTM. OF 2nd FLR SHT'G, TYPICAL BRICK VENEER TO GRADE @ CONC FDN WALL SCALE: 3" = 1'-0" STRUCTURAL SHEATHING THICKNESS VARIES REFER TO FOUNDATION PLAN BRICK VENEER CAST-IN-PLACE CONCRETE FOUNDATION SUBWALL - REFER TO FOUNDATION PLAN FOR WALL THICKNESS @ 24" O.C. HORIZONTAL BRICK WEEP HOLES AIR SPACE, TYPICAL SECTION DETAIL 12" WIDE 'FLASH & SEAL' FLASH'G - TOP OF FLASHING TO BE SEALED w/ FIBERGLASS MESH & TAR, TYP. HOLD THERMOPLY SHT'G 3/8" OFF T/ FOUNDATION - CONTINUOUS, TYPICAL CAULK @ SILL PLATE SILL SEALER, TYPICAL OF GRADE APPROXIMATE LINE @ 3"o.c., TYP. APPROVED FASTENER - OVERHANG FOUNDATION 1/4", TYP. NOTE: - w/ WEEP CARDS 14" O.H. 3 12" (FROM SHT'G) ENLARGED SOFFIT DETAIL w/ BRICK VENEER SCALE: 3" = 1'-0" 5/4 BLOCKING 2x3 BLK'G LADDER @ 24"o.c.,TYPICAL BRICK VENEER - 2" WIDE RIPPERS 638"±1x2 NAILER 1 2 2 2 1x2 NAILER 1 2 FIBERGLASS / ASPHALT SHINGLES - w/ 15# ROOF FELT O.S.B. ROOF SHEATHING - w/ PLY-CLIPS ALUMINUM GUTTER STRUCTURAL SHEATHING APPROVED FASTENER @ 3"o.c., TYP. 2x2 NAILER VENTED SOFFIT 12" x 912" HARDBOARD FRIEZE - TRIM TO MATCH WINDOW HDR HEIGHTS 1'-0" OVERHANG (UNLESS OTHERWISE NOTED ON PLANS) 1x GUTTER BOARD 158" BARGE MOULD - ONLY AS NOTED ON SHEET A1.0 - REFER TO SHEET A1.0 FOR SIZE FIBER CEMENT BOARD SIDING @ BAND BOARD SCALE: 3" = 1'-0" 2"(MIN.)18" 312" 358" STRUCTURAL SHEATHING DOUBLE 2x4 TOP PLATE STRUCTURAL SHEATHING @ SECOND FLOOR NOTE: SECOND FLR STRUCTURAL SHT'G TO OVERLAP FIRST FLR STRUCTURAL SHT'G 2" MINIMUM @ FIRST FLOOR SECTION DETAIL APPROVED FASTENER @ 3"o.c., TYPICAL 8" @ 2x10's6" @ 2x12'sHOLD T/ POLY FLASH'G AT: 8" OFF T/ SUBFLOOR FOR 2x10 JSTS 6" OFF T/ SUBFLOOR FOR 2x12 JSTS APPROVED FASTENER @ 12"o.c. IN BTM 1/3 OF BAND BD APPROVED FASTENER @ 3"o.c., TYPICAL 24" POLY FLASHING @ SECOND FLR. BAND BD - EXTEND PAST BTM OF 2nd FLR SHT'G, TYPICAL FIBER CEMENT BOARD SIDING - PROVIDE 7" EXPOSURE w/ 1 14" LAP - TYPICAL BRICK VENEER @ CAST STONE SILL w/ 1x TRIM SCALE: 3" = 1'-0" SECTION DETAIL METAL DRIP FLASHING, TYP. - NAIL TO SHEATHING - USE 1" ROOFING NAILS @ EA. STUD 214" x 4" CAST STONE SILL, TYP. - PROJECT BTM. 1"± METAL DRIP FLASHING - NAIL & TAPE TO SHEATHING - USE 1" ROOFING NAILS @ EA. STUD 1x TRIM BOARD - REFER TO ELEVATIONS FOR SIZES AND PROFILES BRICK VENEER, TYPICAL 1"±FIBER CEMENT BOARD SIDING - PROVIDE 7" EXPOSURE w/ 1 14" LAP - TYPICAL 178"178"14"10° 10 0° 100 ° 1"± BRICK VENEER @ CAST STONE SILL SCALE: 3" = 1'-0" SECTION DETAIL METAL DRIP FLASHING, TYP. - NAIL & TAPE TO SHEATHING - USE 1" ROOFING NAILS @ EA. STUD 214" x 4" CAST STONE SILL, TYP. - PULL BTM. 1"± BRICK VENEER, TYPICAL 1"± FIBER CEMENT BOARD SIDING - PROVIDE 7" EXPOSURE w/ 1 14" LAP - TYPICAL 11316"11316"1 4"10° 100 ° 100° 1"± 03 02 01 06 05 0407 08 09 10 11 DETAIL w/ FIBER CEMENT BOARD SIDING SCALE: 3" = 1'-0" 2 2 1x GUTTER BOARD ALUMINUM GUTTER STRUCTURAL SHEATHING 2x2 NAILER VENTED SOFFIT 1'-0" OVERHANG (UNLESS OTHERWISE NOTED ON PLANS) 12" x 912" HARDBOARD FRIEZE - TRIM TO MATCH WINDOW HDR HEIGHTS FIBER CEMENT BOARD SIDING - PROVIDE 7" EXPOSURE w/ 1 14" LAP - TYPICAL ENLARGED SOFFIT BLOCKING FIBERGLASS / ASPHALT SHINGLES - w/ 15# ROOF FELT O.S.B. ROOF SHEATHING - w/ PLY-CLIPS APPROVED FASTENER @ 3"o.c., TYP 158" BARGE MOULD - ONLY AS NOTED ON SHEET A1.0 - REFER TO SHEET A1.0 FOR SIZE DRIP EDGE - GUTTER - STYLE 'G' - 234" x 112" - INSTALL DIRECTLY TO OSB, BENEATH UNDERLAYMENT DRIP EDGE - GUTTER - STYLE 'G' - 234" x 112" - INSTALL DIRECTLY TO OSB, BENEATH UNDERLAYMENT BRICK VENEER @ FDN BRICK CURB UP TO 48" SCALE: 3" = 1'-0" SECTION DETAIL STRUCTURAL SHEATHING BRICK VENEER AIR SPACE, TYPICAL 1"- HOLD BTM OF SHEATHING 1" BELOW T/ SUBFLOOR APPROVED FASTENER @ 3"o.c., TYPICAL SILL SEALER, TYPICAL 4" @ 2x10's& 2x12's312" THICKNESS VARIES REFER TO FOUNDATION PLAN 1" 18" WIDE COUNTER FLASHING - HOLD T/ MYLAR 4" OFF T/ SUBFLR 18"w. FLASH & SEAL FLASHING - HOLD T/ FLASHING FLUSH w/ TOP OF FLOOR JOIST- SEAL AROUND ALL PENETRATIONS 8"thk. FOUNDATION WALLS: VERTICAL #4 RE-BARS @ 24" o.c. - MAINTAIN MINIMUM 2" COVER - EXTEND 24" BELOW BTM/ BRICK CURB 10"thk. FOUNDATION WALLS:RE-BAR @ BRICK CURB NOT REQUIRED BRICK VENEER @ FOUNDATION BRICK CURB SCALE: 3" = 1'-0" SECTION DETAIL STRUCTURAL SHEATHING BRICK VENEER AIR SPACE, TYPICAL 1"- HOLD BTM OF SHEATHING 1" BELOW T/ SUBFLOOR APPROVED FASTENER @ 3"o.c., TYPICAL SILL SEALER, TYPICAL 4" @ 2x10's& 2x12's3 12" THICKNESS VARIES REFER TO FOUNDATION PLAN612"d. BRICK CURBMAX. DEPTHw/ NO RE-INFORCINGFOR 8"thk. WALL1" BRICK WEEP HOLES @ 24" o.c. HORIZONTAL - w/ WEEP CARDS NOTE: HOLD T/ GRADE DOWN 812" FROM T/ FOUNDATION WALL 18"w. FLASH & SEAL FLASHING - HOLD 234" DOWN FROM T/ 2x10 JOIST - HOLD 434" DOWN FROM T/ 2x12 JOIST - SEAL AROUND ALL PENETRATIONS 234" @ 2x10's434" @ 2x12's18" WIDE COUNTER FLASHING - HOLD T/ MYLAR 4" OFF T/ SUBFLR THICKNESS VARIES REFER TO FOUNDATION PLAN AIR SPACE, TYPICAL BRICK VENEER STRUCTURAL SHEATHING 38"SILL SEALER, TYPICAL @ 3"o.c., TYP. APPROVED FASTENER - HOLD 3/8" (MIN.) ABOVE T/FOUNDATION BRICK VENEER @ GARAGE FOUNDATION WALL SCALE: 3" = 1'-0" SECTION DETAIL 612" MAX. DEPTH BRICK CURB w/ NO RE-INFORCING 312" 612"MAX. DEPTHw/ NO RE-INFORCINGBRICK WEEP HOLES @ 24" o.c. HORIZONTAL - w/ WEEP CARDS 1" NOTE: HOLD T/ GRADE DOWN 812" FROM T/ FOUNDATION WALL 18"w. FLASH & SEAL FLASHING- SEAL AROUND ALL PENETRATIONS CMU / STONE VENEER @ FDN. BRICK CURB SCALE: 3" = 1'-0" SECTION DETAIL CULTURED STONE VENEER ON 3x8x16 SOLID BLOCK SCRATCH COAT STRUCTURAL SHEATHING AIR SPACE, TYPICAL 1"- HOLD BTM OF SHEATHING 1" BELOW T/ SUBFLOOR APPROVED FASTENER @ 3"o.c., TYPICAL SILL SEALER, TYPICAL 312" THICKNESS VARIES REFER TO FOUNDATION PLAN612"MAX. DEPTHw/ NO RE-INFORCINGFOR 8"thk. WALL1"CMU WEEP HOLES @ 24" o.c. HORIZONTAL - w/ WEEP CARDS 4" @ 2x10's& 2x12'sNOTE: HOLD T/ GRADE DOWN 812" FROM T/ FOUNDATION WALL 18"w. FLASH & SEAL FLASHING - HOLD 234" DOWN FROM T/ 2x10 JOIST - HOLD 434" DOWN FROM T/ 2x12 JOIST- SEAL AROUND ALL PENETRATIONS 234" @ 2x10's434" @ 2x12's18" WIDE COUNTER FLASHING - HOLD T/ MYLAR 4" OFF T/ SUBFLR NOTE: HOLD CULTURED STONE DOWN 1" FROM T/ FDN.WILLIAML.KAU FH O L Z A RCHITECTOVERBROOK FARMSREASON FOR PLOT: PLOT DATE:Job No. Sheet No.IN HOMESITE NO.OFFICE REVIEW:MASTER BY: DATE: C DATE: 3940 OLYMPIC BLVD ERLANGER, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVEDFISCHER HOMES, Inc.JOB INFO:DATE: PERMIT: SIGN-OFF: CONSTRUCTION:REVISION:REVISION:REVISION:REVISION:HOME TYPE:PLAN:2/25/2021 10:58 AM# OBF011000000VIJAYALAKSHMI CUTTAMANCHI3965 BEAR CREEK WAYCLAY46-430-CLAY FRENCH MANOR WITH BRICKCARMEL, IN10005/2017JP------------------------------------------------fieldspecchange@fischerhomes.comREVISED BY:----KIRANKUMAR MANUBOLUSAPPHIRE TRADE SUPPORTsapphiretradepartners@fischerhomes.comFischer Homes Indianapolis II, LLCWS-B2 04/01/21