HomeMy WebLinkAboutE1BASEMENT
CRAWL SPACE SLAB ON GRADE
STORAGE MECH SPACE
SLAB ON GRADE
SLAB ON GRADE
1
Basement Plan - Electrical
1/4" = 1'-0"
E1
Basement - Electrical
Plan
Scale
Date
Project number 19.01
20 JAN 2021
1/4" = 1'-0"
No.
Description
Date
BARBER RESIDENCE
JIM BARBER
12749 WEST ROAD
CARMEL, IN 46077
EVAN ANDERSON-DECINA
11532 CREEKSIDE LANE
CARMEL, IN 46033
WP
GFI, or "G"
SYMBOL DESCRIPTION
LEGEND
DUPLEX RECEPTACLE OUTLET .
'D' FOR DEDICATED OUTLETS
'CS' FOR CHILD SAFETY OUTLETS
DUPLEX FLOOR RECEPTACLE IN CAST IRON FLOOR BOX.
SEE SPECS.
DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER
HEIGHT. MOUNT 6" ABOVE BACK SPLASH U.O.N.
WEATHERPROOF DUPLEX RECEPTACLE
PROVIDE CLEAR PLASTIC IN-USE COVERS.
DUPLEX RECEPTACLE WITH GOURND FAULT CIRCUIT
INTERRUPTER.
20Amp SPST SWITCH (SEE SPECS). 'D' INDICATES DIMMER.
20Amp 3-WAY SWITCH (SEE SPECS).
MANUAL MOTOR STARTER.
CATV OUTLET MOUNTED, VERIFY HEIGHT W/ G.C.
PROVIDE SEMI-RECESSED WALL BOX WITH QUADPLEX
OUTLET AND LOW-VOLTAGE CABLE OUTLET.
U.O.N. UNLESS OTHERWISE NOTED / UNLESS NOTED OTHERWISE
D
S
m
S
3
S
T.V.
O.S.
"OS" INDICATES OCCUPANCY SENSOR, SEE
SPECIFICTIONS BOOK.
TYP (TYP) TYPICAL.
CCT / CKT CIRCUIT.
PNL PANEL.
EC ELECTRICAL CONTRACTOR.
XFRMR TRANSFORMER
NON-FUSED DISCONNECT SWITCH. 3R DENOTES NEMA
CONSTRUCTION TYPE.
FUSED DISCONNECT SWITCH. 60 IS AMP RATING / 50
INDICATES FUSE SIZE, 3R DENOTES NEMA
CONSTRUCTION TYPE.
MOTOR CONNECTION. NUMBER INDICATES
HORSEPOWER RATING.
TELEPHONE OUTLET MOUNTED
ROUTE 1"C. TO ABOVE ACCESSIBLE CEILING. CABLE BY
OTHERS.
10
3R
60/50
3R
TELEPHONE OUTLET MOUNTED ABOVE COUNTER HEIGHT
MOUNT 6" ABOVE COUNTER IN HORIZONTAL
ORIENTATION U.O.N., CABLE BY OTHERS.
FLUSH MOUNTED FLOOR TELEPHONE OUTLET IN CAST
IRON FLOOR BOX (SEE SPECS). ROUTE 1"C. TP ABOVE
ACCESSIBLE CEILING LOCATION. CABLE BY OTHERS.
PUSHBUTTON STARTER PROVIDED BY OTHERS.
PANEL BOARD.
WELL PUMP SWITCH
ELECTRICAL KEY NOTES:
1. COMBO LIGHT/ EXHAUST FAN.
2. GARBAGE DISPOSAL CONNECTION. COORDINATE WITH
PLUMBER AND MILLWORK CONTRACTOR.
3. MICROWAVE CONNECTION. COORDINATE WITH
MILLWORK CONTRACTOR.
4. FURNACE CONNECTION. COORDINATE WITH
MECHANICAL CONTRACTOR.
5. WATER HEATER CONNECTION. COORDINATE WITH
PLUMBING CONTRACTOR.
6. WASHER AND DRYER CONNECTIONS.
7. I.T. PANEL LOCATION.
8. POWER PANEL LOCATION.
9. DISHWASHER CONNECTION. COORDINATE WITH
MILLWORK AND PLUMBING CONTRACTOR.
4
5
S
120V
S
200 AMP SUBPANEL
DEDICATED SUMP
AND LIFT PUMP OUTLETS
20 AMP
D D
GFI GFI
S
3
S
3
S
3
S
R1
W1
S8
S8
S8
GFI
S
GFI
VERIFY CRAWL OUTLET,
SWITCH AND LIGHT LOCATION
S
C1
S
8
1
3 X 2" STUB THRU WALL FOR FUTURE USE
03/23/21