Loading...
HomeMy WebLinkAboutE3 (2)W D E2 First Floor - Electrical Plan Scale Date Project number 19.01 20 JAN 2021 1/4" = 1'-0" No. Description Date BARBER RESIDENCE JIM BARBER 12749 WEST ROAD CARMEL, IN 46077 EVAN ANDERSON-DECINA 11532 CREEKSIDE LANE CARMEL, IN 46033 SCREENED-IN PORCH MASTER BEDROOM LIVING CLOSET MASTER BATH MECH TOILET 1/2 BATH GARAGE KITCHEN BREEZEWAY FOYER LAUNDRY 1 First Floor Plan - Electrical 1/4" = 1'-0" P1 J 9 1 2 3 6 8 ELECTRICAL KEY NOTES: 1. COMBO LIGHT/ EXHAUST FAN. 2. GARBAGE DISPOSAL CONNECTION. COORDINATE WITH PLUMBER AND MILLWORK CONTRACTOR. 3. MICROWAVE CONNECTION. COORDINATE WITH MILLWORK CONTRACTOR. 4. FURNACE CONNECTION. COORDINATE WITH MECHANICAL CONTRACTOR. 5. WATER HEATER CONNECTION. COORDINATE WITH PLUMBING CONTRACTOR. 6. WASHER AND DRYER CONNECTIONS. 7. I.T. PANEL LOCATION. 8. POWER PANEL LOCATION. 9. DISHWASHER CONNECTION. COORDINATE WITH MILLWORK AND PLUMBING CONTRACTOR. 7 400 AMP MCB WITH FEED THRU LUGS. S8 S4 R1 R1 FAN RATED BOX 1 J FAN RATED BOX J FAN RATED BOX S8 S8 J J J J 3 S 3 S SS 3 S 3 S 3 S V36 V24 3 S PE PC M SEE ABOVE FOR LIGHTING W1 W1 W1 COORDINATE ALL WALL LIGHT LOCATIONS WITH OWNER. W1 W1 W1 W1 S +48" GFI / WP GFI / WP GFI / WP GFI / WP GFI / WP GFI / WP GFI / WP GFI / WP GFI / WP GFI +48" GFI +48" GFI +48" GFI +48" +48" GFI GFI GFI GFI GFI +48" +48" 3 S 3 S R1 R1 R1 R1 4 S 3 S 3 S 3 S 3 S 3 S S S R1 R1 S SS GFI S S4 S4 S R1 1 S S GFI R1 R1 S 120V T.V. SSSS S 120V R1 R1 R1 R1 CENTER DOWNLIGHTS IN BEDROOM CORNERS 16" FROM EACH WALL. (TYPICAL ALL) P2 3 S R1 R1 R1 R1 COORDINATE LOCATION FOR FIRE PLACE S S 3 S R1 R1 R1 P1 P1 P1 S T.V. R2 R2 R2 S R2 R2 R2 R2 R2 R2 R2 TO CABINET LIGHTS S GFI GFI USB D GFI GFI GFI GFI GFI GFI GFI WINE D GFI GFI GFI 03/23/21