HomeMy WebLinkAboutE101.0Indiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032102/05/2016PLAN REVISIONS........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2017
Joel Hampshire3/30/2015
GARAGE LEFT
2600-Monaco
1837.0000
--
01/02/2016
PLOTTED: January 3, 2017 / Mike Carney / 2600-IN-MEPP.DWG Opt. Electrical Floor PlansElevation 16.11
\pxql,t1;{\T0.9;ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE (N.E.C.). ALL MATERIAL AND EQUIPMENT SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS LABORATORIES, INC. AND MEET THE REQUIREMENTS OF THE N.E.C..\P\P1. STAIRWAYS WITHIN DWELLING UNITS SHALL HAVE AN ILLUMINATION LEVEL ON THE TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE. PROVIDE LIGHTING CONTROL AT EACH LEVEL. EXTERIOR STAIRWAYS SERVING A DWELLING UNIT SHALL HAVE A LIGHT IN THE IMMEDIATE VICINITY OF THE STAIR LANDING CLOSEST TO THE DWELLING UNIT. \P\P2. GFI PROTECTION SHALL BE PROVIDED FOR ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS:\P - BATHROOMS\P - GARAGE\P - OUTDOORS: BALCONIES, DECKS, AND PORCHES (INCLUDING INSIDE SCREENED ENCLOSURES)\P - UNFINISHED BASEMENT AREAS AND CRAWL SPACES, EXCEPT FOR LAUNDRY CIRCUIT AND SINGLE RECEPTACLE DEDICATED TO SUMP PUMPS\P - RECEPTACLES INTENDED TO SERVE KITCHEN COUNTER TOP SURFACES\P - RECEPTACUTILITY NOTESElectrical Schedule Table
CH
\A1;60'-8" OVERALL AT MASONRY WRAP3SSS
R
3S
R
R
R
R
R
R
GFI
SDISPGFIDW
GFI
S
GFI
GFI
GFI
GFI
DED.
GFIDED.GFIGFI
GFI
PH
3SS4
HC
\A1;60'-8" OVERALL AT MASONRY WRAP
FAN/LIGHT, VENT TO EXT.S
GFIGFIGFI
SS
FAN, VENT TO EXT.
FW.P.
S
GFI
GFI IN KNEE SPACE BELOW
OPT. WALK-IN SHOWER ELEC. PLANSCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0"OPT. GOURMET KITCHEN ELEC. PLANFIRST FLOOR ELECTRICAL PLAN - OPT. 3 CAR FRONT LOADSCALE: 1/4" = 1'-0"
HC HC
\A1;52'-2" OVERALL AT MASONRY WRAP
\A1;60'-8" OVERALL AT MASONRY WRAP
WP/GFISSS
RR3S
3S
GFI
GDOGDOGDO
HC HC
\A1;60'-8" OVERALL AT MASONRY WRAP\A1;60'-8" OVERALL AT MASONRY WRAP
FIRST FLOOR ELECTRICAL PLAN - OPT. 2 CAR COURTYARD WITH STORAGE OPTIONSCALE: 1/4" = 1'-0"
WP/GFISSS
RR3S
3S
GDO
GDO
GFI
\A1;60'-8" OVERALL AT MASONRY WRAP
CH
SCALE: 1/4" = 1'-0"OPT. BUILT-IN KITCHEN ELEC. PLAN
R
3S
R
R
R
R
R
R
GFI
SDISPGFIDW
GFI
S
GFI
GFI
GFI
GFI
DED.
DED.GFIGFI
GFI
PH
3SS4
DED.
\A1;60'-8" OVERALL AT MASONRY WRAP
R
S
SCALE: 1/4" = 1'-0"OPT. FIREPLACE ELEC. PLAN
not applicable in Indiana