Loading...
HomeMy WebLinkAboutE101.0Indiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032102/05/2016PLAN REVISIONS........................ PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2017 Joel Hampshire3/30/2015 GARAGE LEFT 2600-Monaco 1837.0000 -- 01/02/2016 PLOTTED: January 3, 2017 / Mike Carney / 2600-IN-MEPP.DWG Opt. Electrical Floor PlansElevation 16.11 \pxql,t1;{\T0.9;ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE (N.E.C.). ALL MATERIAL AND EQUIPMENT SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS LABORATORIES, INC. AND MEET THE REQUIREMENTS OF THE N.E.C..\P\P1. STAIRWAYS WITHIN DWELLING UNITS SHALL HAVE AN ILLUMINATION LEVEL ON THE TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE. PROVIDE LIGHTING CONTROL AT EACH LEVEL. EXTERIOR STAIRWAYS SERVING A DWELLING UNIT SHALL HAVE A LIGHT IN THE IMMEDIATE VICINITY OF THE STAIR LANDING CLOSEST TO THE DWELLING UNIT. \P\P2. GFI PROTECTION SHALL BE PROVIDED FOR ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS:\P - BATHROOMS\P - GARAGE\P - OUTDOORS: BALCONIES, DECKS, AND PORCHES (INCLUDING INSIDE SCREENED ENCLOSURES)\P - UNFINISHED BASEMENT AREAS AND CRAWL SPACES, EXCEPT FOR LAUNDRY CIRCUIT AND SINGLE RECEPTACLE DEDICATED TO SUMP PUMPS\P - RECEPTACLES INTENDED TO SERVE KITCHEN COUNTER TOP SURFACES\P - RECEPTACUTILITY NOTESElectrical Schedule Table CH \A1;60'-8" OVERALL AT MASONRY WRAP3SSS R 3S R R R R R R GFI SDISPGFIDW GFI S GFI GFI GFI GFI DED. GFIDED.GFIGFI GFI PH 3SS4 HC \A1;60'-8" OVERALL AT MASONRY WRAP FAN/LIGHT, VENT TO EXT.S GFIGFIGFI SS FAN, VENT TO EXT. FW.P. S GFI GFI IN KNEE SPACE BELOW OPT. WALK-IN SHOWER ELEC. PLANSCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"OPT. GOURMET KITCHEN ELEC. PLANFIRST FLOOR ELECTRICAL PLAN - OPT. 3 CAR FRONT LOADSCALE: 1/4" = 1'-0" HC HC \A1;52'-2" OVERALL AT MASONRY WRAP \A1;60'-8" OVERALL AT MASONRY WRAP WP/GFISSS RR3S 3S GFI GDOGDOGDO HC HC \A1;60'-8" OVERALL AT MASONRY WRAP\A1;60'-8" OVERALL AT MASONRY WRAP FIRST FLOOR ELECTRICAL PLAN - OPT. 2 CAR COURTYARD WITH STORAGE OPTIONSCALE: 1/4" = 1'-0" WP/GFISSS RR3S 3S GDO GDO GFI \A1;60'-8" OVERALL AT MASONRY WRAP CH SCALE: 1/4" = 1'-0"OPT. BUILT-IN KITCHEN ELEC. PLAN R 3S R R R R R R GFI SDISPGFIDW GFI S GFI GFI GFI GFI DED. DED.GFIGFI GFI PH 3SS4 DED. \A1;60'-8" OVERALL AT MASONRY WRAP R S SCALE: 1/4" = 1'-0"OPT. FIREPLACE ELEC. PLAN not applicable in Indiana 04/07/21