HomeMy WebLinkAboutA121_electrical_reflectedceilingUP S ND S ND NLEL S ND UP S ND S ND NLEL S ND UP TV TV U.C. REFRGI ENTRY 101 COFFEE 102 OFFICE 103 OFFICE 104 +60" +60" +60" +60" +42" GFCI +44" GFCI UP TV TV U.C. REFRGI ENTRY 101 COFFEE 102 OFFICE 103 OFFICE 104 +60" +60" +60" +60" +42" GFCI +44" GFCI REFLECTED CEILING PLAN A121 REFLECTED CEILING PLAN DATE DESCRIPTION ISSUE 01.08.21 REVIEW SET 01.15.21 PERMIT SET REVISIONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY ACCOLADE WEALTH MANAGEMENT ONE PENN MARK - SUITE 100 11595 N MERIDIAN ST CARMEL, IN 46032 EH EH 2020.265 1ST FLOOR N 0 2' 4' 8' 16' AREA NOT IN CONTRACT AREA OF WORK AREA NOT IN CONTRACT AREA OF WORK ELECTRICAL PLAN NOTES ELECTRICAL PLAN DED POWER OUTLET, DUPLEX NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, QUADRUPLEX JUNCTION BOX POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX BOX, BLANK COVER PLATE BOX, OPEN BOX, BLANK COVER PLATE BOX, OPEN POWER AND DATA POLE FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED DEDICATED CIRCUIT DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) DATA/COMMUNICATION OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE ELECTRICAL LEGEND CEILING MOUNTED JUNCTION BOX CEILING MOUNTED JUNCTION BOX ELECTRICAL PLAN/ MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION RCP PLAN NOTES EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV / HEAT PUMP GENERAL ELEC. NOTES CONTROL ENTRY + COFFEE GENERAL LIGHTING WITH SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. EXISTING DIMMER SWITCH LOCATION TO REMAIN - PROVIDE NEW WHITE BOX + DEVICE TO CONTROL NEW CAN LIGHTING. CONTRACTOR TO INSPECT PLENUM ABOVE DEMISING WALL AND IDENTIFY POSSIBLE CONSTRUCTION AND/OR HVAC SOLUTIONS TO ASSIST IN BLOCKING SOUNDS AND SMELLS FROM ADJACENT SUITE. COORDINATE FINDINGS WITH PROPERTY MANAGEMENT. 0 2' 4' 8' 16' 1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE WITH NEW AS REQUIRED. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. CONTRACTOR TO PROVIDE GFCI OUTLET FOR WATER HEATER AND AUTOMATIC SHUTOFF VALVES AS REQUIRED. 5. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. J J B O J +42" PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT 24" A.F.F. PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT. PROVIDE POWER FOR TENANT'S UNDERCOUNTER REFRIGERATOR AT THIS LOCATION. COORDINATE OUTLET LOCATION WITH CASEWORK - REFER TO ELEVATIONS. PROVIDE DIRECT HDMI HOOK-UP BOX AT THIS LOCATION. INTENT IS FOR CORD TO BE CONNECTED TO TV AND FISHED THROUGH WALL AS MUCH AS POSSIBLE, SUCH THAT TENANT CAN PLUG IN DIRECTLY TO DEVICES. CONFIRM FINAL HEIGHT AND LOCATION OF HDMI BOX WITH TENANT. COORDINATE IT EQUIPMENT PLACEMENT IN THIS AREA WITH TENANT AND TENANT'S DATA VENDOR. PROVIDE SEPARATE PRICE FOR POWER AS REQUIRED AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE REMARKS FOR MORE DETAILS. PROVIDE JUNCTION BOX ABOVE CEILING FOR POWER POLE CONNECTION. POWER POLE BY OTHERS. LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH ND N N3 D 3 EXIT LIGHT FIXTURE LIGHT FIXTURE, 2'x2', BUILDING STANDARD LED LIGHT FIXTURE, 2'x4', BUILDING STANDARD LED RELOCATED DIFFUSER, LAY-IN, 4"x4' RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x2' NEW OR RELOCATED EXISTING TO REMAIN EXIT LIGHT FIXTURE LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH CEILING GRID, SUSPENDED, 2'x2' DIFFUSER, LAY-IN, 4"x4' DIFFUSER, LAY-IN, 2'x2' LIGHT FIXTURE, 2'x2', FLUORESCENT, PARABOLIC LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC RCP LEGEND EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE 1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x2 AT 9'-7" A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 6. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE WITH NEW AS REQUIRED. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. GENERAL NOTES 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES LIGHT SWITCH, DIMMER 6" RECESSED LED LIGHT FIXTURE, DIRECTIONAL A121 1 NLEL 04/13/21