REFLECTED
CEILING PLAN
A121
REFLECTED CEILING PLAN
DATE DESCRIPTION
ISSUE
01.08.21 REVIEW SET
01.15.21 PERMIT SET
REVISIONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
ACCOLADE
WEALTH MANAGEMENT
ONE PENN MARK - SUITE 100
11595 N MERIDIAN ST CARMEL, IN 46032
EH EH
2020.265
1ST FLOOR
N
0 2' 4' 8' 16'
AREA NOT IN CONTRACT
AREA OF WORK
AREA NOT IN CONTRACT
AREA OF WORK
ELECTRICAL PLAN NOTES
ELECTRICAL PLAN
DED
POWER OUTLET, DUPLEX
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
POWER OUTLET, DUPLEX
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
BOX, BLANK COVER PLATE
BOX, OPEN
BOX, BLANK COVER PLATE
BOX, OPEN
POWER AND DATA POLE
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
JUNCTION BOX AND
DATA, FLUSH MOUNTED
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DEDICATED CIRCUIT
DATA/COMMUNICATION
OUTLET (PROVIDE BOX
AND PULL STRING ONLY)
DATA/COMMUNICATION
OUTLET
GFCI GROUND FAULT CIRCUIT
INTERRUPT OUTLET
HEIGHT OF ELECTRICAL
OR DATA DEVICE
ELECTRICAL LEGEND
CEILING MOUNTED
JUNCTION BOX
CEILING MOUNTED
JUNCTION BOX
ELECTRICAL PLAN/
MECHANICAL DIFFUSER RELOCATION
A121
1
*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
RCP PLAN NOTES
EXISTING VAV BOXES OR
HEAT PUMP AND MAIN SUPPLY
DUCTS TO REMAIN
RELOCATE DIFFUSERS &
FLEXDUCT IF REQUIRED
VAV /
HEAT PUMP
GENERAL ELEC. NOTES
CONTROL ENTRY + COFFEE GENERAL LIGHTING WITH SWITCH AT
THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED.
EXISTING DIMMER SWITCH LOCATION TO REMAIN - PROVIDE NEW
WHITE BOX + DEVICE TO CONTROL NEW CAN LIGHTING.
CONTRACTOR TO INSPECT PLENUM ABOVE DEMISING WALL AND
IDENTIFY POSSIBLE CONSTRUCTION AND/OR HVAC SOLUTIONS TO
ASSIST IN BLOCKING SOUNDS AND SMELLS FROM ADJACENT SUITE.
COORDINATE FINDINGS WITH PROPERTY MANAGEMENT.
0 2' 4' 8' 16'
1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL
NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE WITH NEW
AS REQUIRED.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. CONTRACTOR TO PROVIDE GFCI OUTLET FOR WATER HEATER AND
AUTOMATIC SHUTOFF VALVES AS REQUIRED.
5. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
J
J
B
O
J
+42"
PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET
INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT
24" A.F.F.
PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED
TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT
LOCATION WITH TENANT.
PROVIDE POWER FOR TENANT'S UNDERCOUNTER REFRIGERATOR
AT THIS LOCATION. COORDINATE OUTLET LOCATION WITH
CASEWORK - REFER TO ELEVATIONS.
PROVIDE DIRECT HDMI HOOK-UP BOX AT THIS LOCATION. INTENT IS
FOR CORD TO BE CONNECTED TO TV AND FISHED THROUGH
WALL AS MUCH AS POSSIBLE, SUCH THAT TENANT CAN PLUG IN
DIRECTLY TO DEVICES. CONFIRM FINAL HEIGHT AND LOCATION
OF HDMI BOX WITH TENANT.
COORDINATE IT EQUIPMENT PLACEMENT IN THIS AREA WITH
TENANT AND TENANT'S DATA VENDOR.
PROVIDE SEPARATE PRICE FOR POWER AS REQUIRED AT DOOR
FOR CARD READER (CARD READER BY TENANT). COORDINATE
WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE
REMARKS FOR MORE DETAILS.
PROVIDE JUNCTION BOX
ABOVE CEILING FOR
POWER POLE
CONNECTION. POWER
POLE BY OTHERS.
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
ND
N
N3
D
3
EXIT LIGHT FIXTURE
LIGHT FIXTURE, 2'x2',
BUILDING STANDARD LED
LIGHT FIXTURE, 2'x4',
BUILDING STANDARD LED
RELOCATED DIFFUSER,
LAY-IN, 4"x4'
RELOCATED DIFFUSER,
LAY-IN, 2'x2'
CEILING GRID,
SUSPENDED, 2'x2'
NEW OR RELOCATED EXISTING TO REMAIN
EXIT LIGHT FIXTURE
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
CEILING GRID,
SUSPENDED, 2'x2'
DIFFUSER,
LAY-IN, 4"x4'
DIFFUSER,
LAY-IN, 2'x2'
LIGHT FIXTURE, 2'x2',
FLUORESCENT, PARABOLIC
LIGHT FIXTURE, 2'x4',
FLUORESCENT, PARABOLIC
RCP LEGEND
EMERGENCY LIGHT FIXTURE
EMERGENCY LIGHT FIXTURE
1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED.
EXISTING GRID IS 2x2 AT 9'-7" A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN
TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED
TILES WITH NEW TO MATCH EXISTING.
2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM
DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE
CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE
UNIFORM LOOK.
3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,
CONTRACTOR MUST NOTIFY SDI.
5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO
UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A
ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED.
6. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE.
REPLACE WITH NEW AS REQUIRED. WHERE POSSIBLE, GANG MULTIPLE
SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN
SWITCHES ARE SHOWN ADJACENT ON PLAN.
7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
GENERAL NOTES
1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING
H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE
SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS
BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY
APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
MECHANICAL NOTES
LIGHT SWITCH, DIMMER
6" RECESSED LED LIGHT
FIXTURE, DIRECTIONAL
A121
1
NLEL
04/13/21