HomeMy WebLinkAboutS101_GRADE BEAM_SLAB EDGE-Layout1LINE OF FLAT SLAB LINE OF FLAT SLAB
SLOPE 3" TO DOOR
CONTRACTOR TO VERIFY
SLAB AT THIS POINT
SLOPE 3" TO DOOR
LINE OF FLAT SLAB
LINE OF FLAT SLAB
CONTRACTOR TO VERIFY
SLAB AT THIS POINT
B C D
C
3
B D
2
A
A
E
E
1
4
EXISTING BUILDING
CORNER
15'-10 1/4" 15'-3" 28'-10 3/4"
15'-6 1/4" 28'-6 3/4" 4"
4"
59'-4" 8'-4"
CONTRACTOR TO INSTALL CONTROL
JOINTS PER INDUSTRY STANDARDS
VERIFY LOCATION W/ CONTRACTOR
CONTRACTOR TO INSTALL CONTROL
JOINTS PER INDUSTRY STANDARDS
VERIFY LOCATION W/ CONTRACTOR
INSTALL DIAMOND CONTROL
JOINTS @ EACH COLUMN
INSTALL DIAMOND CONTROL
JOINTS @ EACH COLUMN
23'-1 1/4" 22'-4 3/4" 1'-0 1/2"
7'-6" 32'-9" 6'-8"
6'-7 1/2" 8'-3" 7'-9" 8'-3" 1'-10 1/2"
46'-11"
25'-1 3/8" 5 1/2" 7'-3 1/4" 5 1/2" 4'-3 1/4" 5 1/2" 7'-3 1/4" 5 1/2" 1'-1 7/8"
1"
10"
10"
4'-3 1/2" 12'-2" 4'-1" 11'-8 1/2" 6"
15'-2" 4'-11 1/2" 6"
15'-2" 4'-11 1/2" 6"
59'-4" 8'-4"
5'-0 1/2" 1'-7" 1'-7" 4'-10" 1'-4" 1'-4 1/2" 6"
12'-3 1/2"
12'-3 1/2"
9 1/2"
9 1/2"
8 1/2" 23'-1 1/4" 22'-4 3/4" 1'-0 1/2"
10"
10"
4"
4"
4"
4"
10"
10"
10"
9" 11'-5" 9" 10'-11 1/2"
SLAB EDGE SHALL BE PINNED TO GRADE
BEAM BY SURVEYOR - DIMENSIONS SHALL
BE COORDINATED WITH ARCHITECT.
FLOOR
FLOOR
FLOOR
10'-2" 8'-0" 8'-0"
15'-0 1/2"
8'-5 3/4"
FLOOR
8'-1 1/4"
LINE OF FLAT SLAB LINE OF FLAT SLAB
SLOPE 3" TO DOOR
CONTRACTOR TO VERIFY
SLAB AT THIS POINT
SLOPE 3" TO DOOR
LINE OF FLAT SLAB LINE OF FLAT SLAB
8" WIDE FOUNDATION
TO EXISTING FOOTING
NOTIFY ARCHITECT OF ANY
DISCREPANCIES TO ASSUMED
EXISTING CONDITIONS
5" x 5" x 3/8" COL
W/ 12" x 12" x 3/4" BASE PLATE
5" x 5" x 3/8" COL
W/ 12" x 12" x 3/4" BASE PLATE
5" x 5" x 3/8" COL
W/ 12" x 12" x 3/4" BASE PLATE
5" x 5" x 3/8" COL
W/ 12" x 12" x 3/4" BASE PLATE
5" x 5" x 3/8" COL
W/ 12" x 12" x 3/4" BASE PLATE
5" x 5" x 3/8" COL
W/ 12" x 12" x 3/4" BASE PLATE
8 1/2" 23'-1 1/4" 22'-4 3/4" 1'-0 1/2"
CONTRACTOR TO VERIFY
SLAB AT THIS POINT
15'-10 1/4"
1"
15'-3" 28'-10 3/4"
4" 61'-0" 7'-10"
7'-3" 33'-5" 7'-2"
36" x 60" x 12" COL PAD
W/ (5) #6 EACH WAY
60" x 60" x 12" COL PAD
W/ (5) #6 EACH WAY
48" x 48" x 12" COL PAD
W/ (4) #6 EACH WAY
36" x 48" x 12" COL PAD
W/ (4) #6 EACH WAY
36" x 48" x 12" COL PAD
W/ (4) #6 EACH WAY
36" x 60" x 12" COL PAD
W/ (4) #6 EACH WAY
1'-11 5/8" 3'-4 3/4" 2'-0" 9'-0 3/4" 2'-0" 3'-4 3/4" 2'-0" 1'-0 1/4" 1'-2" 6'-6 3/4" 1'-2" 3'-6 3/4" 1'-2" 6'-6 3/4" 1'-2" 1'-7 5/8"
47'-10"
8" 8'-1 1/2"
37'-4 1/2"
1'-8"
12" x 12" FOOTING
DROP 8"
12" x 12" FOOTING
DROP 8"
36" x 36" x 12" COL PAD
W/ (3) #6 EACH WAY
12" x 12" FOOTING
DROP 8"
20" x 12" FOOTING
DROP 8"
15'-2 1/2" 1'-8" 9'-11 1/4" 3'-0" 5'-11" 1'-6"
1'-8" 6'-4"
3'-10"
3'-0 3/4" 1'-0" 6'-3 1/4" 29'-10" 5'-4"
8'-10"
1'-0" 3'-6" 1'-0"
8" 45'-6" 1'-8"
4"
4"
10'-9 1/2" 5'-5" 10'-4 1/2"
4'-8 1/2" 3'-0" 6'-5 5/8" 3'-8 5/8"
2'-0 3/4" 3'-0" 3'-0 3/4"
8" WIDE FOUNDATION
TO EXISTING FOOTING
NOTIFY ARCHITECT OF ANY
DISCREPANCIES TO ASSUMED
EXISTING CONDITIONS
1'-8" 7'-10"
6" 6"
6"
1'-8"
1'-8"
B C D
C
3
B D
2
A
A
E
E
1
4
EXISTING BUILDING
CORNER
8" THICKENED SLAB
UNDER DROPPED EDGE
8" THICKENED SLAB
UNDER DROPPED EDGE
C
A301
C
A301
D
A301
C
A301
B
A301
A
A301
B
A301
A
A301
C
A301
C
A301
D
A301
C
A301
B
A301
A
A301
B
A301
A
A301
SCALE:
F
1/4" = 1' - 0"
GRADE BEAM PLAN S101
GRADE BEAM &
SLAB EDGE PLAN
ALL IDEAS, DESIGNS AND PLANS INDICATED OR
REPRESENTED BY THESE DRAWINGS ARE OWNED
BY, AND THE PROPERTY OF STUART R SHADE, RA.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE
FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS
RESERVED, EXCEPT FOR USES EXPRESSLY
PERMITTED IN WRITING.
SHEET NUMBER:
CERTIFICATION:
PROJECT :
PROPOSED PROFESSIONAL BUILDING
VILLAGE 10, LLC
LOT 62
12755 HORSEFERRY STREET
REV 1:
CARMEL, INDIANA 46032
CARMEL PERMIT SET 3_11_21
SRS ARCHITECTS
200 S RANGELINE RD , #226
INC
CARMEL, INDIANA 46032
PHONE: 317-989-6248
E-MAIL : sshade@mitschdesign.com
T
A
N
N
I
A
R
A
T
U
S
A
E
R
I
G
T
S
R
T
R.
H
S
STATE OF
E
E
D
D
E
R
E
A
I
D
I
T
C
H
C
AR00034184
SCALE:
F
1/4" = 1' - 0"
SLAB EDGE PLAN
04/13/21