HomeMy WebLinkAbout1448 Springmill Circle Permit Set 2021.04.06 (dragged)COVER SHEET AND GENERAL NOTES
ALEXANDER RESIDENCE
CARMEL, IN 46032
A0
1448 SPRINGMILL CIRCLE
ALEXANDER RESIDENCE
BASEMENT REMODEL
815 SF (GROSS)
1. ALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES,
ORDINANCES, RULES, REGULATIONS, AND STANDARDS, INCLUDING, BUT NOT LIMITED TO:
THE INDIANA BUILDING CODE, THE INDIANA CODES, THE INDIANA FIRE CODES, THE
AMERICANS WITH DISABILITIES ACT (ADA), UNIVERSAL BUILDING CODE, AND APPLICABLE
TRADE STANDARDS. ALL APPLICABLE RULES AND REGULATIONS ARE TO BE THE MOST
CURRENT ADOPTED EDITIONS.
2. THE ERRORS AND OMISSIONS DESIGN LIABILITY FOR THE PROJECT SHALL BE LIMITED TO
THE DESIGN COST OF CORRECTING THE DEFICIENCY
3. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL STATE AND LOCAL PERMITS
REQUIRED FOR COMPLETION OF THIS PROJECT.
4. DO NOT SCALE DRAWINGS.
5. THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL CONDITIONS PRIOR TO
COMMENCING WORK. ANY DISCREPANCIES SHALL BE REPORTED TO THE DESIGNER. ANY
ERRORS AND/OR OMISSIONS SHALL BE NOTED AND SENT TO THE OWNER AND DESIGN
TEAM PRIOR TO STARTING THAT PORTION OF WORK AND WITH ADEQUATE TIME TO
REVIEW AND RESPOND.
6. DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION, ALL EXISTING EXITS
SHALL BE CONTINUOUSLY MAINTAINED.
7. ALL METAL FASTENERS AND OTHER METAL ITEMS IN CONTACT WITH CONCRETE OR
MASONRY TO BE GALVANIZED.
8. CONTRACTOR IS RESPONSIBLE TO PROTECT EXISTING STRUCTURE AND MEP SYSTEMS
UNLESS REQUIRED.
9. REPAIR, PATCH AND PAINT ALL CONSTRUCTION DAMAGE TO MATCH EXISTING FINISHES.
10.WATER-RESISTANT GYP. BD. SHALL BE USED AT ALL WET LOCATIONS. CEMENT BOARD
WITH WATERPROOF MEMBRANE SHALL BE USED AS TILE BACKER BOARD.
11.CONTRACTOR TO VERIFY ROUGH-IN PLUMBING LOCATIONS. CONTACT DESIGNER IF
THERE ARE ANY DISCREPENCIES.
12.ALL DRAWINGS AND SPECIFICATIONS PROVIDED ARE CONSIDERED TO BE
COMPLIMENTARY. ITEMS SHOWN IN ONE LOCATION IN THE DRAWINGS OR INCLUDED IN
THE SPECIFICATIONS SHALL BE CONSIDERED PART OF THE WORK AND SHALL APPLY AT
SIMILAR LOCATIONS THROUGHOUT THE PROJECT. IN THE EVENT OF INCONSISTENCIES
BETWEEN THE DRAWINGS PROVIDED BY THE VARIOUS INVOLVED DISCIPLINES, THE
CONTRACTOR SHALL SEEK CLARIFICATION OR INTERPRETATION FROM THE OWNER'S
REPRESENTATIVE PRIOR TO THE WORK. WHERE INCONSISTENCIES ARE NOT CLARIFIED
PRIOR TO BIDDING, THE CONTRACTOR SHALL PROVIDE THE GREATER QUALITY OF WORK
AS DETERMINED BY THE OWNER'S REPRESENTATIVE.
A0 COVER SHEET AND GENERAL NOTES
A1 ARCHITECTURAL PLAN
A2 REFLECTED CEILING PLAN
A3 ELECTRICAL LOCATION PLAN
A4 WALL SECTIONS
A5 FINISH PLAN
GENERAL NOTES
PROJECT LOCATION
SHEET INDEX
04.06.2021
PROJECT LOCATION
04/15/21