HomeMy WebLinkAboutS100.034'-3"
21'-2 1/8"
11'-11 5/8"
CL
+/- 16'-1"
CL
+/- 17'-6 1/2"
CL
11'-1"
C
L
11'-1"
5'-3"
2'-3 1/4" 2'-3 1/4" 7'-1 3/16"
F/I NEW 3-PLY 1-3/4” X 16”H LVL BEAM SUPPORT AT
BOTTOM OF EXISTING GARAGE CEILING JOISTS FOR
ATTIC FLOOR SUPPORT
NEW 3" OD ADJUSTABLE STEEL POST ON 24"
SQUARE X 8"T CAST-IN-PLACE CONCRETE PIER
TO BE CENTERED BETWEEN GARAGE DOORS
F/I NEW 2-PLY 1-3/4” x 16”H LVL HEADER TO REPLACE
EXISTING WINDOW HEADER
F/I NEW 3-PLY 2X4 POST FROM BOTTOM OF NEW LVL
BEAM TO EXISTING BOTTOM PLATE IN EXISTING WALL
F/I (3) NEW SKYLIGHTS; ROUGH
OPENINGS @ 21" W x 37 3/8" H
#1
of
14
Date:
03.24.21
Sheet:
Revision:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been
prepared by Case Design &
Remodeling solely for its use and
should not be reproduced or relied
upon by any other parties.
Dimensions shown or scaled are
subject to change per actual job
condition and must be verified.
Materials are to be supplied as
specified as equal or standard
when not uniquely specified.
Installed materials may vary in
appearance from drawings.
Reference manufacturer's product
data for actual appearance and
specifications.
Ferguson Residence
Attic& Bathroom Remodel
Ann Marie & Bradford Ferguson
14283 Dove Drive,
Carmel, IN 46033
Approved By:
Date:
A102
CONTRACT
Jessica VanLiew
Designer
jvanliew@caseindy.com
Dawn Ashburn
Project Developer
dashburn@caseindy.com
PROPOSED FLOOR PLAN - GARAGE
SCALE: 1/4" = 1'
04/16/21