Loading...
HomeMy WebLinkAboutD300&S300 - P.3 Demolition & Structural PlanSERVER 302 CONFERENCE 303 ENTRY 301 FOCUS 318 FOCUS 317 OFFICE 304 EXEC OFFICE 305 OPEN OFFICE COPY 314 315 OFFICE 308 OFFICE 309 STG. 310 OFFICE 311 OFFICE 312 OFFICE 313 EXEC OFFICE 307 BREAK 306 4'-8" 10'-5" 10'-5" 13'-5" 12'-71 4 " 10'-5" 11'-5" 10'-5" 16'-3" 5'-5" 12'-5" 4'-0" (CLEAR) 7'-41 2 " 8'-91 2 " 6'-01 4 " 17'-61 2 " 5'-0" (CLEAR) 7'-31 4 " FE 11'-63 4 " 16'-103 4 " 4'-0" (CLEAR) WALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT TYPICAL WALL TYPE METAL STUD EXISTING WINDOW MULLION EQUAL & ARCHITECTURAL FLOOR PLAN A111 AREA NOT IN CONTRACT ARCHITECTURAL PLAN AREA OF WORK WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL W1 WALL WITH INSULATION 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. DATE DESCRIPTION ISSUE 03.12.21 REVIEW SET 03.15.21 PERMIT SET 03.24.21 CONSTRUCTION SET REVISIONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY PUBLIC RISK CITY CENTER AT PENN - SUITE 325 1320 CITY CENTER DRIVE, CARMEL, IN 46032 SDH/EH CB/NP 2020.269 3RD FLOOR N 0 2' 4' 8' 16' ARCH. GENERAL NOTES ARCH. PLAN NOTES TYP. A111 1 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x4'x 3 4", PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT PROVIDED SIGNAGE. CONFIRM EXACT REQUIREMENTS WITH TENANT. PROVIDE FULL HEIGHT X 3'-0" WIDE, 1 4" THICK, TEMPERED GLASS WINDOW WITH TOP AND BOTTOM TRACK TO MATCH DOOR FRAME COLOR. PROVIDE 18" DEEP X 10'-0" LONG PLASTIC LAMINATE (PL_) COUNTER AT 42" AFF. SUPPORT COUNTER AS REQUIRED WITH RAKKS EH-1818-FM BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. _______________________________________________________________ PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL AUTOMATIC SHUTOFF VALVES AS REQUIRED. PROVIDE WATER LINE FOR REFRIGERATOR AND WATER COOLER. CONFIRM LOCATION WITH TENANT. PARTIAL HEIGHT WALL 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO 5'-0" PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED; PROVIDE DRYWALL TOP CAP. W2 W2 A211 3 A211 2 AREA NOT IN CONTRACT DECONSTRUCTION PLAN AREA OF WORK 0 2' 4' 8' 16' NOT TO SCALE WALL AT MULLION DETAIL A111 1 DECON. GENERAL NOTES 1. REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET T111. 2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR SALVAGED FOR LANDLORD. FOR ALL ITEMS DETERMINED FOR REMOVAL, REFER TO THE RECYCLING INSTRUCTIONS. 3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED. 4. SALVAGE REMOVED LIGHT FIXTURES AND HVAC DIFFUSERS FOR REUSE WHERE POSSIBLE. SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. REFER TO RECYCLING INSTRUCTIONS FOR FIXTURES THAT WILL NOT BE SALVAGED. 5. SALVAGE REMOVED DOORS FOR REUSE WHERE POSSIBLE. SEE DOOR SCHEDULE FOR MORE INFORMATION. REFER TO RECYCLING INSTRUCTIONS FOR DOORS THAT WILL NOT BE SALVAGED. ELECTRIC OUTLET(S) DATA OR COMMUNICATION OUTLET EXISTING TO BE REMOVED EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WALL DOOR AND FRAME CEILING GRID AND TILES, 2'x4' SUPPLY AIR DIFFUSERS LIGHT FIXTURE, FLUORESCENT, 2'x4' LIGHT FIXTURE, CAN LIGHT SWITCH LIGHT FIXTURE, FLUORESCENT, 2'x2' WINDOW / SIDELIGHT CEILING GRID AND TILES, 2'x2' LIGHT FIXTURE, TRACK LIGHT FIXTURE, SCONCE LIGHT FIXTURE, PENDANT EXIT LIGHT LIGHT FIXTURE, FLUORESCENT EXHAUST FAN EMERGENCY LIGHT PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL LEGEND SALVAGE FOR RELOCATION schottXchange PICKUP (SEE RECYCLING NOTES) REMOVE EXISTING FLOOR CORE AND INFILL AS REQUIRED TO MAINTAIN BUILDING CONSTRUCTION TYPE. PREPARE FLOOR FOR NEW FINISHES AS REQUIRED. DECON. PLAN NOTES DECONSTRUCTION 04/19/21