HomeMy WebLinkAboutD300&S300 - P.3 Demolition & Structural PlanSERVER
302
CONFERENCE
303
ENTRY
301
FOCUS
318
FOCUS
317
OFFICE
304
EXEC
OFFICE
305
OPEN OFFICE
COPY 314
315
OFFICE
308
OFFICE
309
STG.
310
OFFICE
311
OFFICE
312
OFFICE
313
EXEC
OFFICE
307
BREAK
306
4'-8" 10'-5" 10'-5" 13'-5"
12'-71
4
"
10'-5" 11'-5" 10'-5" 16'-3" 5'-5"
12'-5" 4'-0"
(CLEAR)
7'-41
2
" 8'-91
2
"
6'-01
4
"
17'-61
2
"
5'-0"
(CLEAR)
7'-31
4
"
FE
11'-63
4
" 16'-103
4
"
4'-0"
(CLEAR)
WALL
THICKNESS
PRE-FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
TYPICAL WALL TYPE
METAL STUD
EXISTING WINDOW
MULLION
EQUAL & ARCHITECTURAL
FLOOR PLAN
A111
AREA NOT IN CONTRACT ARCHITECTURAL PLAN
AREA OF WORK
WALL
DOOR AND FRAME
(SEE DOOR SCHEDULE)
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT WINDOW / SIDELIGHT
ARCHITECTURAL LEGEND
PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL
W1 WALL WITH INSULATION
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
WALL TYPES
W1
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
DATE DESCRIPTION
ISSUE
03.12.21 REVIEW SET
03.15.21 PERMIT SET
03.24.21 CONSTRUCTION SET
REVISIONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
PUBLIC RISK
CITY CENTER AT PENN - SUITE 325
1320 CITY CENTER DRIVE, CARMEL, IN 46032
SDH/EH CB/NP
2020.269
3RD FLOOR
N
0 2' 4' 8' 16'
ARCH. GENERAL NOTES
ARCH. PLAN NOTES
TYP.
A111
1
1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
PROVIDE PLYWOOD PHONE BOARD, 4'x4'x
3
4", PAINTED WITH FIRE
RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY
CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED
ACCORDING TO NFPA 10.
PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
TENANT PROVIDED SIGNAGE. CONFIRM EXACT REQUIREMENTS
WITH TENANT.
PROVIDE FULL HEIGHT X 3'-0" WIDE,
1
4" THICK, TEMPERED GLASS
WINDOW WITH TOP AND BOTTOM TRACK TO MATCH DOOR
FRAME COLOR.
PROVIDE 18" DEEP X 10'-0" LONG PLASTIC LAMINATE (PL_)
COUNTER AT 42" AFF. SUPPORT COUNTER AS REQUIRED WITH
RAKKS EH-1818-FM BRACKET ATTACHED TO METAL STUDS WITH
WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL
SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS
NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE
APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS
NEEDED.
_______________________________________________________________
PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL
AUTOMATIC SHUTOFF VALVES AS REQUIRED.
PROVIDE WATER LINE FOR REFRIGERATOR AND WATER COOLER.
CONFIRM LOCATION WITH TENANT.
PARTIAL HEIGHT WALL
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO 5'-0"
PROVIDE 1" STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED; PROVIDE DRYWALL TOP CAP.
W2
W2
A211
3
A211
2
AREA NOT IN CONTRACT DECONSTRUCTION PLAN
AREA OF WORK
0 2' 4' 8' 16' NOT TO SCALE
WALL AT MULLION DETAIL
A111
1
DECON. GENERAL NOTES
1. REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET T111.
2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE
CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR
SALVAGED FOR LANDLORD. FOR ALL ITEMS DETERMINED FOR
REMOVAL, REFER TO THE RECYCLING INSTRUCTIONS.
3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN
ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW
FINISHES AS REQUIRED.
4. SALVAGE REMOVED LIGHT FIXTURES AND HVAC DIFFUSERS FOR
REUSE WHERE POSSIBLE. SEE REFLECTED CEILING PLAN FOR MORE
INFORMATION. REFER TO RECYCLING INSTRUCTIONS FOR
FIXTURES THAT WILL NOT BE SALVAGED.
5. SALVAGE REMOVED DOORS FOR REUSE WHERE POSSIBLE. SEE
DOOR SCHEDULE FOR MORE INFORMATION. REFER TO
RECYCLING INSTRUCTIONS FOR DOORS THAT WILL NOT BE
SALVAGED.
ELECTRIC OUTLET(S)
DATA OR
COMMUNICATION
OUTLET
EXISTING TO BE REMOVED EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT
WALL
DOOR AND FRAME
CEILING GRID AND
TILES, 2'x4'
SUPPLY AIR DIFFUSERS
LIGHT FIXTURE,
FLUORESCENT, 2'x4'
LIGHT FIXTURE, CAN
LIGHT SWITCH
LIGHT FIXTURE,
FLUORESCENT, 2'x2'
WINDOW / SIDELIGHT
CEILING GRID AND
TILES, 2'x2'
LIGHT FIXTURE, TRACK
LIGHT FIXTURE, SCONCE
LIGHT FIXTURE,
PENDANT
EXIT LIGHT
LIGHT FIXTURE,
FLUORESCENT
EXHAUST FAN
EMERGENCY LIGHT
PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL
LEGEND
SALVAGE FOR
RELOCATION
schottXchange PICKUP
(SEE RECYCLING NOTES)
REMOVE EXISTING FLOOR CORE AND INFILL AS REQUIRED TO
MAINTAIN BUILDING CONSTRUCTION TYPE. PREPARE FLOOR FOR
NEW FINISHES AS REQUIRED.
DECON. PLAN NOTES
DECONSTRUCTION
04/19/21