HomeMy WebLinkAboutLS300 - P.2 Life Safety PlanREFRIG BY TENANT REFRIG BY TENANT DW MICROMICRO SNACK ICE REFRIG BY TENANT COKE VEND VEND ENTRY 301 6x6 6x6 6x6 6x6 OPEN OFFICE 314 6x6 6x6 COPY 315 MICRO REFRIG BY TENANT FE 6x6 6x6 ELN ELN ELN ELN ELN x SERVER 302 6'-3" 7'-0" x CONFERENCE 303 21'-7" 13'-0" ENTRY 301 x FOCUS 318 5'-7" 8'-5" x FOCUS 317 5'-7" 8'-5" x OFFICE 304 11'-2" 13'-0" x EXEC OFFICE 305 16'-6" 13'-0" 6x6 6x6 6x6 6x6 OPEN OFFICE 314 6x6 6x6 COPY 315 MICRO REFRIG BY TENANT x OFFICE 308 10'-0" 12'-0" x OFFICE 309 10'-0" 12'-0" x STG. 310 15'-10" 8'-3" x OFFICE 311 x 12'-0" 10'-0" OFFICE 312 x 12'-0" 11'-0" OFFICE 313 12'-0" 10'-0" x EXEC OFFICE 307 13'-0" 17'-4" x BREAK 306 13'-0" 14'-6" FE 6x6 6x6 ELN ELN ELN ELN ELN LIFE SAFETY PLAN L100 LIFE SAFETY PLAN DATE DESCRIPTION ISSUE 03.12.21 REVIEW SET 03.15.21 PERMIT SET 03.24.21 CONSTRUCTION SET REVISIONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY PUBLIC RISK CITY CENTER AT PENN - SUITE 325 1320 CITY CENTER DRIVE, CARMEL, IN 46032 SDH/EH CB/NP 2020.269 3RD FLOOR N 0 4' 8' 16' AREA NOT IN CONTRACT AREA OF WORK LIFE SAFETY NOTES GENERAL NOTES SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACE TOTAL BUILDING AREA TOTAL PROJECT AREA CHANGE OF OCCUPANCY CLASS? OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD NO OCCUPANCY CLASSIFICATION B(USINESS) GEN. OFFICE SF 100 SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 TOTAL AREA ON THE FLOOR SF SF/FLOOR X STORIES SF SF 45,576 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A = TOTAL OCCUPANTS IN PROJECT AREA 39 CODE SUMMARY PREVIOUS USE OF SPACE B(USINESS) ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN) BUILT BEFORE 1978? NO 3,887 3,887 45,576 3 136,728 39 BUILDING CONSTRUCTION TYPE II-B L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. EXISTING ELECTRICAL PANEL LOCATION EXISTING EXIT EP EX LEGEND FIRE EXTINGUISHER EXIT SIGN FE EMERGENCY LIGHT FE - BUILDING STAIR LOCATION TRAVEL DISTANCE NUMBER OF EXITS REQUIRED: 1 PROVIDED: 2 TRAVEL DISTANCE = 111' 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. BUSINESS BUSINESS BUSINESS BUSINESS L100 1 0 4' 8' 16' ENLARGED PLAN L100 1 EX EX EX 04/19/21