HomeMy WebLinkAboutLS300 - P.2 Life Safety PlanREFRIG
BY
TENANT
REFRIG
BY
TENANT
DW
MICROMICRO
SNACK
ICE
REFRIG
BY
TENANT
COKE
VEND
VEND
ENTRY
301
6x6 6x6
6x6 6x6
OPEN OFFICE
314
6x6
6x6
COPY
315
MICRO
REFRIG
BY
TENANT
FE
6x6
6x6
ELN
ELN
ELN
ELN
ELN
x
SERVER
302
6'-3" 7'-0"
x
CONFERENCE
303
21'-7" 13'-0"
ENTRY
301
x
FOCUS
318
5'-7" 8'-5"
x
FOCUS
317
5'-7" 8'-5"
x
OFFICE
304
11'-2" 13'-0"
x
EXEC
OFFICE
305
16'-6" 13'-0"
6x6 6x6
6x6 6x6
OPEN OFFICE
314
6x6
6x6
COPY
315
MICRO
REFRIG
BY
TENANT
x
OFFICE
308
10'-0" 12'-0"
x
OFFICE
309
10'-0" 12'-0"
x
STG.
310
15'-10" 8'-3"
x
OFFICE
311
x 12'-0" 10'-0"
OFFICE
312
x 12'-0" 11'-0"
OFFICE
313
12'-0" 10'-0"
x
EXEC
OFFICE
307
13'-0" 17'-4"
x
BREAK
306
13'-0" 14'-6"
FE
6x6
6x6
ELN
ELN
ELN
ELN
ELN
LIFE SAFETY
PLAN
L100
LIFE SAFETY PLAN
DATE DESCRIPTION
ISSUE
03.12.21 REVIEW SET
03.15.21 PERMIT SET
03.24.21 CONSTRUCTION SET
REVISIONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
PUBLIC RISK
CITY CENTER AT PENN - SUITE 325
1320 CITY CENTER DRIVE, CARMEL, IN 46032
SDH/EH CB/NP
2020.269
3RD FLOOR
N
0 4' 8' 16'
AREA NOT IN CONTRACT
AREA OF WORK
LIFE SAFETY NOTES GENERAL NOTES
SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACE
TOTAL BUILDING AREA
TOTAL PROJECT AREA
CHANGE OF OCCUPANCY CLASS?
OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD
NO
OCCUPANCY CLASSIFICATION B(USINESS)
GEN. OFFICE SF 100
SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES 0
TOTAL AREA ON THE FLOOR
SF
SF/FLOOR X STORIES SF
SF
45,576 SF
ACCESSORY AREA EXCEEDS 10% NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
=
TOTAL OCCUPANTS IN PROJECT AREA 39
CODE SUMMARY
PREVIOUS USE OF SPACE B(USINESS)
ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN)
BUILT BEFORE 1978? NO
3,887
3,887
45,576 3 136,728
39
BUILDING CONSTRUCTION TYPE II-B
L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT
SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS
REQUIRED TO MEET ALL LOCAL AND STATE CODES.
EXISTING ELECTRICAL PANEL LOCATION
EXISTING EXIT
EP
EX
LEGEND
FIRE EXTINGUISHER
EXIT SIGN
FE
EMERGENCY LIGHT
FE
- BUILDING STAIR LOCATION
TRAVEL DISTANCE
NUMBER OF EXITS REQUIRED: 1 PROVIDED: 2
TRAVEL DISTANCE = 111'
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
BUSINESS
BUSINESS
BUSINESS
BUSINESS
L100
1
0 4' 8' 16'
ENLARGED PLAN
L100
1
EX
EX
EX
04/19/21