Loading...
HomeMy WebLinkAboutRCP300&E300 - P.4 Reflected Ceiling Plan & ElectricalS ND SN S N SN S N SN S N SN S N SN SN SN S N S N3 S N3 ELN ELN ELN ELN ELN S ND S ND B A NL NL NL S ND SN S N SN S N SN S N SN S N SN SN SN S N S N3 S N3 ELN ELN ELN ELN ELN S ND S ND B A NL NL NL SERVER 302 CONFERENCE 303 TV ENTRY 301 FOCUS 318 FOCUS 317 OFFICE 304 EXEC OFFICE 305 6x6 6x6 6x6 6x6 OPEN OFFICE 314 6x6 6x6 COPY 315 MICRO REFRIG BY TENANT OFFICE 308 OFFICE 309 STG. 310 OFFICE 311 OFFICE 312 OFFICE 313 EXEC OFFICE 307 BREAK 306 +60" +60" DED DED +24" DED J J +42" +42" GFCI GFCI +44" 6x6 6x6 +44" +44" +60" +60" USB USB SERVER 302 CONFERENCE 303 TV ENTRY 301 FOCUS 318 FOCUS 317 OFFICE 304 EXEC OFFICE 305 6x6 6x6 6x6 6x6 OPEN OFFICE 314 6x6 6x6 COPY 315 MICRO REFRIG BY TENANT OFFICE 308 OFFICE 309 STG. 310 OFFICE 311 OFFICE 312 OFFICE 313 EXEC OFFICE 307 BREAK 306 +60" +60" DED DED +24" DED J J +42" +42" GFCI GFCI +44" 6x6 6x6 +44" +44" +60" +60" USB USB REFLECTED CEILING PLAN A121 REFLECTED CEILING PLAN DATE DESCRIPTION ISSUE 03.12.21 REVIEW SET 03.15.21 PERMIT SET 03.24.21 CONSTRUCTION SET REVISIONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY PUBLIC RISK CITY CENTER AT PENN - SUITE 325 1320 CITY CENTER DRIVE, CARMEL, IN 46032 SDH/EH CB/NP 2020.269 3RD FLOOR N 0 2' 4' 8' 16' ELECTRICAL PLAN NOTES ELECTRICAL PLAN DED POWER OUTLET, DUPLEX NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, QUADRUPLEX JUNCTION BOX POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX BOX, BLANK COVER PLATE BOX, OPEN BOX, BLANK COVER PLATE BOX, OPEN POWER AND DATA POLE FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED DEDICATED CIRCUIT DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) DATA/COMMUNICATION OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE ELECTRICAL LEGEND CEILING MOUNTED JUNCTION BOX CEILING MOUNTED JUNCTION BOX ELECTRICAL PLAN/ A121 1 MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION RCP PLAN NOTES EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV / HEAT PUMP GENERAL ELEC. NOTES CONTROL ENTRY 301, BREAK 306, COPY 315, AND OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. 0 2' 4' 8' 16' 1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE WITH NEW AS REQUIRED. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. CONTRACTOR TO PROVIDE GFCI OUTLET FOR WATER HEATER AND AUTOMATIC SHUTOFF VALVES AS REQUIRED. 5. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. J J B O J +42" PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS. COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND DATA. COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. PROVIDE DIRECT HDMI/VGA CONDUIT CONNECTION FROM FLOOR CORE POKE THRU DEVICE TO WALL MOUNTED MONITOR. PROVIDE RECESSED ELECTRICAL, DATA, AND CABLE OUTLET 60" A.F.F. AND CORE AT FLOOR IN WALL FOR TENANT PROVIDED FLAT SCREEN MONITOR. COORDINATE WITH TENANT ON EXACT LOCATION. PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT 24" A.F.F. PROVIDE POWER/DATA IN WALL AS REQUIRED FOR TENANT PROVIDED SIGNAGE. CONFIRM EXACT REQUIREMENTS WITH TENANT. CONFIRM EXACT REQUIREMENTS WITH TENANT FOR EQUIPMENT REQUIREMENTS. COORDINATE RECEPTACLE WITH TENANT. PROVIDE ALTERNATE PRICE FOR FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. PROVIDE POWER AS NEEDED FOR TENANT'S WATER COOLER. PROVIDE JUNCTION BOX ABOVE CEILING FOR POWER POLE CONNECTION. POWER POLE BY OTHERS. LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH ND N N3 D 3 EXIT LIGHT FIXTURE LIGHT FIXTURE, LED PENDANT - SEED DESIGN DORA P3 MULTI-LIGHT PENDANT LIGHT - CHROME RECESSED LIGHT FIXTURE LIGHT FIXTURE, 2'x2', FLUORESCENT, DIRECT/INDIRECT LIGHT FIXTURE, 2'x4', FLUORESCENT, DIRECT/INDIRECT RELOCATED DIFFUSER, LAY-IN, 4"x4' RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x2' NIGHT LIGHT NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, 1'x4', FLUORESCENT, INDIRECT LIGHT FIXTURE, PENDANT LIGHT FIXTURE, 1'x4', FLUORESCENT, INDIRECT EXIT LIGHT FIXTURE LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH CEILING GRID, SUSPENDED, 2'x2' DIFFUSER, LAY-IN, 4"x4' DIFFUSER, LAY-IN, 2'x2' GYPSUM BOARD CEILING LIGHT FIXTURE, 2'x2', FLUORESCENT, DIRECT/INDIRECT LIGHT FIXTURE, 2'x4', FLUORESCENT, DIRECT/INDIRECT RCP LEGEND RECESSED LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EXHAUST FAN, 2'x2' EXHAUST FAN, 2'x2' GYPSUM BOARD CEILING NE SWITCH, EXHAUST FAN E SWITCH, EXHAUST FAN 1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x2 AT 9'-6" A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. GENERAL NOTES 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES LIGHT SWITCH, DIMMER AREA NOT IN CONTRACT AREA OF WORK AREA NOT IN CONTRACT AREA OF WORK LIGHT FIXTURE, LED PENDANT - DWELED ETERNAL LED PENDANT LIGHT - CHROME RECEPTACLE TO BE DUPLEX WITH 2 USB PORTS USB 04/19/21