SERVER
302
CONFERENCE
303
TV
ENTRY
301
FOCUS
318
FOCUS
317
OFFICE
304
EXEC
OFFICE
305
6x6 6x6
6x6 6x6
OPEN OFFICE
314
6x6
6x6
COPY
315
MICRO
REFRIG
BY
TENANT
OFFICE
308
OFFICE
309
STG.
310
OFFICE
311
OFFICE
312
OFFICE
313
EXEC
OFFICE
307
BREAK
306
+60"
+60"
DED
DED
+24" DED
J J
+42"
+42"
GFCI
GFCI
+44"
6x6
6x6
+44"
+44"
+60"
+60"
USB
USB
SERVER
302
CONFERENCE
303
TV
ENTRY
301
FOCUS
318
FOCUS
317
OFFICE
304
EXEC
OFFICE
305
6x6 6x6
6x6 6x6
OPEN OFFICE
314
6x6
6x6
COPY
315
MICRO
REFRIG
BY
TENANT
OFFICE
308
OFFICE
309
STG.
310
OFFICE
311
OFFICE
312
OFFICE
313
EXEC
OFFICE
307
BREAK
306
+60"
+60"
DED
DED
+24" DED
J J
+42"
+42"
GFCI
GFCI
+44"
6x6
6x6
+44"
+44"
+60"
+60"
USB
USB
REFLECTED
CEILING PLAN
A121
REFLECTED CEILING PLAN
DATE DESCRIPTION
ISSUE
03.12.21 REVIEW SET
03.15.21 PERMIT SET
03.24.21 CONSTRUCTION SET
REVISIONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
PUBLIC RISK
CITY CENTER AT PENN - SUITE 325
1320 CITY CENTER DRIVE, CARMEL, IN 46032
SDH/EH CB/NP
2020.269
3RD FLOOR
N
0 2' 4' 8' 16'
ELECTRICAL PLAN NOTES
ELECTRICAL PLAN
DED
POWER OUTLET, DUPLEX
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
POWER OUTLET, DUPLEX
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
BOX, BLANK COVER PLATE
BOX, OPEN
BOX, BLANK COVER PLATE
BOX, OPEN
POWER AND DATA POLE
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
JUNCTION BOX AND
DATA, FLUSH MOUNTED
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DEDICATED CIRCUIT
DATA/COMMUNICATION
OUTLET (PROVIDE BOX
AND PULL STRING ONLY)
DATA/COMMUNICATION
OUTLET
GFCI GROUND FAULT CIRCUIT
INTERRUPT OUTLET
HEIGHT OF ELECTRICAL
OR DATA DEVICE
ELECTRICAL LEGEND
CEILING MOUNTED
JUNCTION BOX
CEILING MOUNTED
JUNCTION BOX
ELECTRICAL PLAN/
A121
1
MECHANICAL DIFFUSER RELOCATION
A121
1
*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
RCP PLAN NOTES
EXISTING VAV BOXES OR
HEAT PUMP AND MAIN SUPPLY
DUCTS TO REMAIN
RELOCATE DIFFUSERS &
FLEXDUCT IF REQUIRED
VAV /
HEAT PUMP
GENERAL ELEC. NOTES
CONTROL ENTRY 301, BREAK 306, COPY 315, AND OPEN OFFICE
AREA LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE
MULTIPLE SWITCHES AS REQUIRED.
0 2' 4' 8' 16'
1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL
EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE.
REPLACE WITH NEW AS REQUIRED.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. CONTRACTOR TO PROVIDE GFCI OUTLET FOR WATER HEATER AND
AUTOMATIC SHUTOFF VALVES AS REQUIRED.
5. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
J
J
B
O
J
+42"
PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER
(CARD READER BY TENANT). COORDINATE WITH TENANT'S
SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE
DETAILS.
COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE
FOR JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM.
COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT
LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT
FOR APPROVAL PRIOR TO ORDERING.
PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE
FOR ELECTRICAL AND DATA. COORDINATE WITH TENANTS
FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU
DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO
ORDERING. PROVIDE DIRECT HDMI/VGA CONDUIT CONNECTION
FROM FLOOR CORE POKE THRU DEVICE TO WALL MOUNTED
MONITOR.
PROVIDE RECESSED ELECTRICAL, DATA, AND CABLE OUTLET 60"
A.F.F. AND CORE AT FLOOR IN WALL FOR TENANT PROVIDED FLAT
SCREEN MONITOR. COORDINATE WITH TENANT ON EXACT
LOCATION.
PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET
INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT
24" A.F.F.
PROVIDE POWER/DATA IN WALL AS REQUIRED FOR TENANT
PROVIDED SIGNAGE. CONFIRM EXACT REQUIREMENTS WITH
TENANT.
CONFIRM EXACT REQUIREMENTS WITH TENANT FOR EQUIPMENT
REQUIREMENTS. COORDINATE RECEPTACLE WITH TENANT.
PROVIDE ALTERNATE PRICE FOR FLUSH MOUNT FLOOR CORE WITH
POKE THRU DEVICE FOR JUNCTION BOX AND DATA FOR TENANT'S
FURNITURE SYSTEM. COORDINATE WITH TENANTS FURNITURE
VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE
SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING.
PROVIDE POWER AS NEEDED FOR TENANT'S WATER COOLER.
PROVIDE JUNCTION BOX
ABOVE CEILING FOR
POWER POLE
CONNECTION. POWER
POLE BY OTHERS.
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
ND
N
N3
D
3
EXIT LIGHT FIXTURE
LIGHT FIXTURE, LED
PENDANT - SEED
DESIGN DORA P3
MULTI-LIGHT PENDANT
LIGHT - CHROME
RECESSED LIGHT
FIXTURE
LIGHT FIXTURE, 2'x2',
FLUORESCENT,
DIRECT/INDIRECT
LIGHT FIXTURE, 2'x4',
FLUORESCENT,
DIRECT/INDIRECT
RELOCATED DIFFUSER,
LAY-IN, 4"x4'
RELOCATED DIFFUSER,
LAY-IN, 2'x2'
CEILING GRID,
SUSPENDED, 2'x2'
NIGHT LIGHT
NEW OR RELOCATED EXISTING TO REMAIN
LIGHT FIXTURE, 1'x4',
FLUORESCENT, INDIRECT
LIGHT FIXTURE,
PENDANT
LIGHT FIXTURE, 1'x4',
FLUORESCENT, INDIRECT
EXIT LIGHT FIXTURE
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
CEILING GRID,
SUSPENDED, 2'x2'
DIFFUSER,
LAY-IN, 4"x4'
DIFFUSER,
LAY-IN, 2'x2'
GYPSUM BOARD CEILING
LIGHT FIXTURE, 2'x2',
FLUORESCENT,
DIRECT/INDIRECT
LIGHT FIXTURE, 2'x4',
FLUORESCENT,
DIRECT/INDIRECT
RCP LEGEND
RECESSED LIGHT
FIXTURE
EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE
EXHAUST FAN, 2'x2' EXHAUST FAN, 2'x2'
GYPSUM BOARD CEILING
NE SWITCH, EXHAUST FAN E
SWITCH, EXHAUST FAN
1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED.
EXISTING GRID IS 2x2 AT 9'-6" A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN
TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED
TILES WITH NEW TO MATCH EXISTING.
2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM
DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE
CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE
UNIFORM LOOK.
3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,
CONTRACTOR MUST NOTIFY SDI.
5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO
UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A
ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED.
6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE
POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE
MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON
PLAN.
7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
GENERAL NOTES
1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING
H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE
SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS
BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY
APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
MECHANICAL NOTES
LIGHT SWITCH, DIMMER
AREA NOT IN CONTRACT
AREA OF WORK
AREA NOT IN CONTRACT
AREA OF WORK
LIGHT FIXTURE, LED
PENDANT - DWELED
ETERNAL LED PENDANT
LIGHT - CHROME
RECEPTACLE TO BE
DUPLEX WITH 2 USB PORTS
USB
04/19/21