Loading...
HomeMy WebLinkAboutLS1.2 - LIFE SAFETYSheet Number: Sheet Title: LS1.2 LIFE SAFETY PLAN Project: Developer: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date Myron Cromer 885 MONON GREEN BLVD., SUITE 101 SCALE: NTS PLAN NORTH KEY PLAN PEDCOR DESIGN GROUP LLC THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. JAMES R. STUTZMAN, AIA, Carmel, Indiana. State Release Set Project: Developer: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date TJ MAGIC HAT BARBER SHOP Carmel, Indiana 46032 THE HAMILTON WEST BUILDING SCALE: NTS PLAN NORTH KEY PLAN THE HAMILTON PEDCOR DESIGN GROUP LLC THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2021 JAMES R. STUTZMAN, AIA, Carmel, Indiana. THE HAMILTON BUILDING SUITE 101 Friday, March 12, 2021, /Volumes/ALLDATA/MS/DESIGN/PROJECTS/CARMEL CITY CENTER/CCC Drawings/CCC Construction Doc/Building E/Building E.CAD/Building E.Interiors/TENANTS/MAGIC HAT BARBER SHOP/DRAWINGS/IBASE-MAGIC HAT.pln MAGIC HAT BARBER SHOP LIFE SAFETY & CODE SUMMARY PROJECT SUMMARY This project is a new tenant improvement project known as the MAGIC HAT BARBER SHOP, occupying 912 square feet of the ground floor of an existing Shell and Core project known as The Hamilton West Building. The MAGIC HAT BARBER SHOP project occupies approximately six and a half percent (6.5%) of the ground floor area of a single story building. The MAGIC HAT BARBER SHOP project is a Group B occupancy, and the construction type of this project and the shell and core is I-B. The entire facility is fully protected by an automatic sprinkler system. The MAGIC HAT BARBER SHOP tenant is a Business Occupancy providing hair care services. APPLICABLE CODES & STANDARDS Indiana General Administrative Rules (675 IAC 12) 2006 Indiana Building Code (IBC 2012) 2014 Accessibility-Indiana Building Code (ANSI A117.1-2009) 2014 Minimum Design Loads for Buildings (ASCE 7-2010) 2014 Indiana Plumbing Code, 2012 Edition 2012 Indiana Mechanical Code, 2014 Edition (IMC 2012) 2014 Indiana Electrical Code, 2008 Edition (NFPA 70-2008) 2009 Indiana Fuel Gas Code, 2014 Edition (IFGC 2012) 2014 Indiana Fire Code (IFC 2012) 2014 Indiana Energy Conservation Code (ASHRAE 90.1 2007) 2010 NFPA 10-2010 Portable Fire Extinguishers 2012 NFPA 13-2010 Installation of Fire Sprinkler Systems 2012 NFPA 72-2010 National Fire Alarm Code 2014 NFPA 90A- Installation of Air Conditioning & Ventilating Systems 2015 NFPA 90m — Installation of Warm Air Heating & Air Conditioning Systems 2015 ADA Standards for Accessible Design 2010 OCCUPANCY CLASSIFICATIONS: MAGIC HAT BARBER SHOP Tenant: Group B Building Shell & Core: Group A-2, A-3, B, M OCCUPANT LOAD: MAGIC HAT BARBER SHOP Total Gross Area 912 sq ft B Occupancy 912 sf @ 100 sf/person 9 persons CONSTRUCTION TYPES: MAGIC HAT BARBER SHOP Tenant: Type I-B Building Shell & Core: Type I-B BUILDING AREAS: MAGIC HAT BARBER SHOP Tenant: 912 sf Shell & Core: (Ground Floor) 13,857 sf FIRE RESISTANCE: MAGIC HAT BARBER SHOP Tenant & Shell & Core (Ground Floor): Walls: All construction to be non-combustible Exit Passageways: 2 hours Fire walls: 2 hours Exit Access Corridors: 1 hour INTERIOR FINISHES: MAGIC HAT BARBER SHOP Tenant & Shell & Core (Ground Floor): Vertical Exits & Passageways: Class B Exit Access Corridors Class C All Others Class C FIRE PROTECTION: 100% protection by an automatic sprinkler system per NFPA 13-1999 100% protection by a fire alarm & annunciator system meeting NFPA 72-2002 ACCESSIBILITY REQUIREMENTS: All tenant restrooms comply with ICC/ANSI A117.1-2003; Section 604.5.1 PREVIOUS IDHS APPROVALS: Project No. 415013 CDR Letter Standard Release - Architectural, Structural, Mechanical, Electrical, Plumbing 06.19.07 W DR REST ROOM 102 BACK ROOM 103 R IM HALLWAY 104 HALLWAY 101 BARBER SHOP AREA 100 49' - 3" 51' - 2" N RI RI RI SCALE: 1/4" = 1'-0" 1 LIFE SAFETY PLAN LS1.2 LEGEND EGRESS PATH, POINT OF BEGINNING EGRESS PATH, POINT OF EXITING EGRESS PATH, DISTANCE TRAVEL X'-X" 2/9/21 2/9/21 REVISIONS 3/12/21 N-E NE 4,668 04/19/21