Loading...
HomeMy WebLinkAboutA1.2 - REFLECTED CEILING PLAN_ELECTRICALSheet Number: Sheet Title: A1.2 REFLECTED CEILING/ ELECTRICAL PLANS Project: Developer: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date Myron Cromer 885 MONON GREEN BLVD., SUITE 101 SCALE: NTS PLAN NORTH KEY PLAN PEDCOR DESIGN GROUP LLC THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. JAMES R. STUTZMAN, AIA, Carmel, Indiana. State Release Set Project: Developer: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue Date TJ MAGIC HAT BARBER SHOP Carmel, Indiana 46032 THE HAMILTON BUILDING SCALE: NTS PLAN NORTH KEY PLAN THE HAMILTON PEDCOR DESIGN GROUP LLC THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2021 JAMES R. STUTZMAN, AIA, Carmel, Indiana. THE HAMILTON BUILDING SUITE 101 Tuesday, February 9, 2021, /Volumes/ALLDATA/MS/DESIGN/PROJECTS/CARMEL CITY CENTER/CCC Drawings/CCC Construction Doc/Building E/Building E.CAD/Building E.Interiors/TENANTS/MAGIC HAT BARBER SHOP/DRAWINGS/IBASE-MAGIC HAT.pln 6'-0" 3'-4" 5'-1" 5'-1" 3'-4" 11'-0" 10'-0" 6'-0" OPEN CP1 CP4 CP2 CP6 CP9 CP10 CP3 CP5 CP6 CP8 CP10 CP5 CP7 CP8 CP10 E2 A B D E1 E1 C C E2 E2 A A A A A A A A A A A A A A A A A A A A A A A C C W DR GFI J J J J J J EP7 EP1 EP6 EP8 EP2 EP4 EP4 EP4 EP6 EP5 EP1 EP2 EP3 EP2 EP9 EP10 REST ROOM 102 BACK ROOM 103 R +44" +80" ABOVE +44" WH +144" IM +132" +132" HALLWAY 104 HALLWAY 101 BARBER SHOP AREA 100 +144" +44" ABOVE +44" ABOVE J ELECTRICAL CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. GENERAL CEILING NOTES: CEILING PLAN NOTES: PROVIDE FIRE RATED DAMPERS WHERE REQUIRED AT FIRE RATED WALLS. EMERGENCY STROBES TO BE WHITE AND EMERGENCY LIGHT FIXTURES TO BE WHITE UNLESS NOTED OTHERWISE. COORDINATE IN THE FIELD WITH THE ARCHITECT AND TENANT. INSTALL ACOUSTICAL CEILING PANELS WITH GRAIN/TEXTURE RUNNING IN THE SAME DIRECTION UNLESS NOTED OTHERWISE. PROVIDE LIGHTING CONTROL TIMER SYSTEM FOR THIS SUITE WITH (6) ZONES TO MEET ENERGY CODE. 12. 11. 10. 9. 5. 6. 7. 4. 1. 2. 3. HVAC DIFFUSERS AND GRILLES, FIRE SPRINKLERS ARE TO BE CENTERED WITHIN CEILING TILES. REFLECTED CEILING LEGEND: WALLS GO TO DECK ABOVE. SEE CONSTRUCTION PLAN FOR WALL TYPE INFORMATION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR & ENGINEER TO PROVIDE COMPLETE HVAC PACKAGE (INCLUDING INDOOR AND OUTDOOR UNITS, POWER FROM THE TENANT'S PANEL, DISTRIBUTION DUCTWORK, AND FRESH AIR SUPPLY), SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CEILING HEIGHT IS INDICATED BY BENCHMARK. BLOCKING AND SUPPORTS ARE TO BE PROVIDED FOR ALL CEILING MOUNTED FIXTURES AS NEEDED. 13. LIGHTING CONTROLS. 2' X 2' SUSPENDED CEILING TO BE: ARMSTRONG, 2'X2' DUNE ANGLED TEGULAR, W/ PRELUDE XL 15/16" GRID. EXHAUST GRILLE IN CEILING FOR EXHAUST SYSTEM. 14. 15. MEP CONSULTANT TO RUN THE NECESSARY CALCULATIONS TO DETERMINE THAT THE LIGHTING LAYOUT MEETS THE ENERGY CODE. IF IT DOES NOT PLEASE ADDRESS THIS WITH THE ARCHITECT AND THE TENANT TO REVISE LIGHT SELECTIONS AS NEEDED. MEP CONSULTANT IS TO SUBMIT DRAWINGS SHOWING LOCATIONS OF ALL NECESSARY OCCUPANCY SENSORS, HORN STROBES, FIRE PULLS AND EMERGENCY LIGHTS. CP1 REMOVE DRY FALL OVERSPRAY FROM ALL SURFACES BESIDES THE FIRE RATED DECK AND BEAMS ABOVE. ALL LIGHT FIXTURES TO BE 3000K COLOR TEMPERATURE. SYMBOL TYPE LIGHT FIXTURE SCHEDULE DESCRIPTION MODEL WATTAGE MOUNTING HEIGHT NOTES EMERGI-LITE, PREMIER SERIES – EXIT SIGN, W- PREM-XX-R. EMERGENCY EXIT SIGNS EMERGENCY LIGHTS EMERGI-LITE, EF43D-LED. WALL 16. OCCUPANCY SENSORS TO BE MOUNTED IN THE CEILING OR ON THE WALL AT A LOCATION THAT SENSES ONLY MOVEMENT FROM INSIDE OF THE ROOM. REVIEW LOCATIONS WITH ARCHITECT. B A FLUSH MOUNT DOWNLIGHT KUZCO LIGHTING, FALCO FLUSH MOUNT DOWNLIGHT, FM 10605, WHITE. 12'-0" TO BOTTOM W/ CONDUIT & J-BOX 15W CP2 EXISTING OPEN CEILING TO REMAIN. HVAC UNITS, DUCTWORK AND CONDUIT TO REMAIN UNPAINTED. ACENT LIGHT FIXTURE OXYGEN, NEBULA PENDANT, 3-681-15. 30W 10'-0" TO BOTOM ELCO LIGHTING, 6” ROUND RECESSED LED, EL627 W/EL770ICA HOUSING. C RECESSED DOWNLIGHT 20W CEILING D WALL SCONCE SHADES OF LIGHT, MOD MIX WHITE GLOBE VANITY LIGHT-2 LIGHT, BLACK. E1 PENDANT LIGHT FIXTURE CAMMAN LIGHTING, MASON, P7100-12 STAIN BLACK (PSB) WITH OPAL GLASS E2 20W XW 7'-0" AFF TO BOTTOM OF FIXTURE JUNCTION BOX LIGHTS ON DIMMERS. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. COORDINATE ALL SWITCHING AND LOCATIONS WITH THE TENANT AND ARCHITECT. 8. NL NIGHT LIGHT. CEILING LIGHT ON DIMMER. 8'-0" TO BOTTOM W/ CONDUIT & J-BOX LIGHTS ON DIMMERS. PENDANT LIGHT FIXTURE CAMMAN LIGHTING, MASON, P7100-12 STAIN BLACK (PSB) WITH OPAL GLASS 20W 10'-0" TO BOTTOM W/ CONDUIT & J-BOX LIGHTS ON DIMMERS. CP3 PROVIDE DIMMER SWITCHES FOR THE ACCENT LIGHTS AT THIS LOCATION. CP4 CONTROL OVERALL LIGHTING FROM TIMER AT THIS LOCATION. CP5 PROVIDE NEW SUSPENDED CEILING TO BE: ARMSTRONG, DUNE 2X2, SQUARE LAY-IN WITH PRELUDE XL 15/16” GRID. CP6 PROVIDE COMPLETE HVAC PACKAGE INCLUDING INDOOR AND OUTDOOR UNITS, POWER FROM THE TENANTS’ PANEL, DISTRIBUTION DUCTWORK, AND FRESH AIR SUPPLY. LOCATE MECHANICAL UNIT ABOVE SUSPENDED CEILING. USE SPIRAL DUCT IN OPEN CEILING AREA. ALL EXPOSED MECHANICAL AND ELECTRICAL ITEMS ARE TO REMAIN UNPAINTED. CP7 PROVIDE EXHAUST WITH FAN AND DUCTWORK TO THE OUTSIDE. CP8 LIGHTS TO BE ON OCCUPANCY SENSOR. 17. CONTACT TRACI ASHCRAFT, SPECIFIED LIGHTING SYSTEMS, 317-863-7024 FOR LIGHTING PRODUCTS. CP10 INSTALL LIFE SAFETY ITEMS AS REQUIRED FOR TENANT BUILD-OUT. INCLUDE ADDITIONAL FIRE SPRINKLER HEADS FROM EXISTING SYSTEM AND FIRE ALARMS, SENSORS AND WIRING BACK TO MAIN MODULE. CP9 LIGHTS TO BE ON TIMER SYSTEM. J TV GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AND WIRING FROM THE TENANT'S PHONE BOARD TO EACH VOICE/DATA DROP. TERMINATIONS ARE TO BE INCLUDED AT EACH DROP. ELECTRICAL/DATA PLAN NOTES: FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER,CONSTRUCTION MANAGER, AND/OR DESIGN- BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE UNLESS NOTED OTHERWISE. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF TO THE CENTER UNLESS NOTED OTHERWISE. 7. 8. 6. 5. 4. 3. DUPLEX ELECTRICAL WALL OUTLET. ELECTRICAL/DATA LEGEND: GFI GROUND FAULT INTERRUPT CIRCUIT DUPLEX ELECTRICAL OUTLET. DATA OUTLET WITH (2) INTERNET CONNECTIONS. +44" HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. EP1 EP2 ALL FURNITURE, FIXTURES, AND EQUIPMENT TO BE SUPPLIED BY TENANT UNLESS NOTED OTHERWISE. PROVIDE NEW ELECTRICAL AND DATA OUTLETS. COORDINATE ELECTRICAL WITH TENANT PROVIDED EQUIPMENT. 9. ALL PENETRATIONS THROUGH THE DEMISING WALLS BETWEEN TENANTS AND BETWEEN THE TENANT AND THE SERVICE CORRIDOR NEED TO BE FIRE RATED. 10. FIRE ALARM SYSTEM SHALL BE COMPATIBLE AND TIED TO THE EXISTING BUILDING FIRE ALARM SYSTEM. 1. 2. ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. ELECTRICAL JUNCTION BOX IN-FLOOR DUPLEX ELECTRICAL OUTLET. DATA OUTLET WITH (1) CABLE CONNECTION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR & ENGINEER TO PROVIDE COMPLETE HVAC PACKAGE (INCLUDING INDOOR AND OUTDOOR UNITS, POWER FROM THE TENANT'S PANEL, DISTRIBUTION DUCTWORK, AND FRESH AIR SUPPLY), SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. D DEDICATED CIRCUIT QUAD ELECTRICAL OUTLET. DATA OUTLET WITH PHONE LINE CONNECTION. FAX IN-FLOOR DATA OUTLET WITH (2) INTERNET CONNECTIONS. EP3 PROVIDE A RECESSED ELECTRICAL PANEL FOR THIS TENANT SUITE WITH CONDUIT EXTENDED FROM THE METER. POWER FOR HVAC IS TO BE INCLUDED ON THE TENANT PANEL. EP4 PROVIDE ELECTRICAL SUPPLY FOR WALL MOUNTED, BACK-LIT MIRRORS. EP5 PROVIDE POWER FOR WATER HEATER. EP6 PROVIDE POWER FOR AN OUTDOOR SIGN AND INTERIOR BARBER POLE PROVIDED BY THE TENANT. EP7 PROVIDE FLOOR MOUNTED QUAD ELECTRICAL OUTLET. EP8 PROVIDE FLOOR MOUNTED DUPLEX ELECTRICAL OUTLET. EP9 PROVIDE POWER FOR TENANT SUPPLIED WASHER AND DRYER. EP10 PROVIDE POWER FOR TENANT SUPPLIED ICE MAKER. 1.5 2.1 2 1 3.1 0.9 1.6 3 1.6 M N Q 1.5 2.1 2 1 3.1 0.9 1.6 3 1.6 M N Q N N SCALE: 1/4" = 1'-0" 1 REFLECTED CEILING PLAN A1.2 SCALE: 1/4" = 1'-0" 2 ELECTRICAL/DATA PLAN A1.2 2/9/21 2/9/21 04/19/21