HomeMy WebLinkAboutE121 Electrical and Reflected CeilingUP DN OPEN OFFICE STG. 419 424 RR 418 MULTIPURPOSE ROOM 423 LF STORAGE 433 +60" +60" +44" GFCI P J J J UP DN OPEN OFFICE STG. 419 424 RR 418 MULTIPURPOSE ROOM 423 LF STORAGE 433 +60" +60" +44" GFCI P J J J UP DN S N3 SN S N SN NLEL NLEL S N UP DN S N3 SN S N SN NLEL NLEL S N REFLECTED CEILING PLAN A121 REFLECTED CEILING PLAN DATE DESCRIPTION ISSUE 03.23.2021 REVIEW SET 03.25.2021 PERMIT SET REVISIONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY AMERICAN PAIN CONSORTIUM EXPANSION ONE PENN MARK | SUITE 400 11595 N MERIDIAN, CARMEL IN 46032 EH JR 2020.299 4TH FLOOR N 0 2' 4' 8' 16' AREA NOT IN CONTRACT AREA OF WORK AREA NOT IN CONTRACT AREA OF WORK ELECTRICAL PLAN NOTES ELECTRICAL PLAN DED POWER OUTLET, DUPLEX NEW CONSTRUCTION EXISTING TO REMAIN JUNCTION BOX POWER OUTLET, DUPLEX JUNCTION BOX POWER AND DATA POLE DEDICATED CIRCUIT DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) DATA/COMMUNICATION OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE ELECTRICAL LEGEND ELECTRICAL PLAN/ A121 1 MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION RCP PLAN NOTES EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV / HEAT PUMP GENERAL ELEC. NOTES CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION, TIE INTO EXISTING OPEN OFFICE CIRCUIT. PROVIDE MULTIPLE SWITCHES AS REQUIRED. REWORK ANY EXISTING LIGHTING AND LIFE SAFETY ELEMENTS IN THIS LOCATION AS REQUIRED TO WORK WITH NEW WALL LAYOUT AND COMPLY WITH ALL STATE AND LOCAL CODES. PROVIDE OCCUPANCY SENSOR FOR LIGHTING IN THIS ROOM. 0 2' 4' 8' 16' 1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL NEW DEVICES AND FACE PLATES TO MATCH EXISTING. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. CONTRACTOR TO PROVIDE GFCI OUTLET FOR WATER HEATER AND AUTOMATIC SHUTOFF VALVES AS REQUIRED. 5. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. J +42" PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS. PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT. DESIGN INTENT IS TO TIE INTO TENANT'S EXISTING POWER POLE FOR WORKSTATIONS AT THIS LOCATION. PROVIDE JUNCTION BOX ABOVE CEILING FOR POWER POLE CONNECTION. POWER POLE BY OTHERS. LIGHT SWITCH, 3-WAY LIGHT SWITCH N N3 3 EXIT LIGHT FIXTURE RECESSED LIGHT FIXTURE LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC RELOCATED DIFFUSER, LAY-IN, 4"x4' RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x2' NIGHT LIGHT/EMERGENCY LIGHT NEW OR RELOCATED EXISTING TO REMAIN EXIT LIGHT FIXTURE LIGHT SWITCH, 3-WAY LIGHT SWITCH CEILING GRID, SUSPENDED, 2'x2' DIFFUSER, LAY-IN, 4"x4' DIFFUSER, LAY-IN, 2'x2' LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC RCP LEGEND RECESSED LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EXHAUST FAN, 2'x2' EXHAUST FAN, 2'x2' 1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x2 AT 8'-8" A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 8. PROVIDE SEPARATE PRICE FOR CEILING GRID TO REMAIN AND ALL CEILING TILES TO BE REPLACED WITH NEW. TILES TO MATCH SUITE STANDARD. 9. PROVIDE SEPARATE PRICE TO PROVIDE ALL NEW, 2X4 LED LAY-IN LIGHT FIXTURES THROUGHOUT TO MATCH BUILDING STANDARD. GENERAL NOTES 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES EMERGENCY LIGHT FIXTURE 04/19/21