Loading...
HomeMy WebLinkAboutA111 Deconstruction and ArchitecturalUP DN UP DN OPEN OFFICE STG. 419 424 RR 418 MULTIPURPOSE ROOM 423 STORAGE 433 8'-5" 5'-5" (HOLD) 7'-11" 9'-11" 7'-11" 115° ALIGN FE WALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT TYPICAL WALL TYPE METAL STUD EXISTING WINDOW MULLION EQUAL & ARCHITECTURAL FLOOR PLAN A111 AREA NOT IN CONTRACT ARCHITECTURAL PLAN AREA OF WORK WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL DEMISING WALL WITH SECURITY MESH 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" SOUND BATT INSULATION EACH SIDE OF WALL ABOVE CEILING; PROVIDE METAL SECURITY MESH ON TOP OF WALL ABOVE CEILING TO DECK W1 WALL WITH INSULATION 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W2 WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. DATE DESCRIPTION ISSUE 03.23.2021 REVIEW SET 03.25.2021 PERMIT SET REVISIONS MARK DATE DB DESCRIPTION THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY AMERICAN PAIN CONSORTIUM EXPANSION ONE PENN MARK | SUITE 400 11595 N MERIDIAN, CARMEL IN 46032 EH JR 2020.299 4TH FLOOR N 0 2' 4' 8' 16' DECONSTRUCTION PLAN REMOVE EXISTING CABINETRY AND COUNTERTOP. REMOVE EXISTING SINK. NO SERVICE SINKS ARE BEING REMOVED. REMOVE EXISTING WALL AT THIS LOCATION. REMOVE PLASTIC LAMINATE WINDOW SILL AT THIS LOCATION; PREPARE DRYWALL SILL FOR NEW FINISHES AS REQUIRED. DECON. PLAN NOTES AREA NOT IN CONTRACT AREA OF WORK DECONSTRUCTION ARCH. GENERAL NOTES ARCH. PLAN NOTES TYP. A111 1 0 2' 4' 8' 16' NOT TO SCALE WALL AT MULLION DETAIL A111 1 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 3. ALL EXISITING WINDOW BLINDS THROUGHOUT SUITE ARE TO BE CLEANED. CONFIRM ALL BLINDS ARE IN GOOD, WORKING ORDER. REPAIR, OR REPLACE, ANY DAMAGED OR MISSING BLINDS AS REQUIRED. ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. NEW FIRE EXTINGUISHER AND SEMI-RECESSED CABINET TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. SEMI-RECESSED CABINET TO BE PAINTED TO MATCH ADJACENT WALL. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. CONSTRUCT NEW CORRIDOR WALL TO MATCH ADJACENT CORRIDOR WALL CONSTRUCTION. CONTRACTOR TO CONFIRM IN FIELD ALL CONDITIONS. PROVIDE 8'-0" H X 13'-5" W, 3 8" TEMPERED GLASS IN TIMELY FRAME, PAINTED TO MATCH SUITE STANDARD. PROVIDE MULTIPLE, EQUAL SIZED PANES WITH BUTT-GLAZE TRANSITION AS REQUIRED. PROVIDE CLEAR POLYMER STRIPS AT TRANSITION BETWEEN PANELS. NO SILICONE SEALANT PERMITTED. PROVIDE (5) 18"D WHITE MELAMINE SHELVES ON HEAVY DUTY KV BRACKETS AND STANDARDS AT THIS LOCATION. _______________________________________________________________ PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL AUTOMATIC SHUTOFF VALVES AS REQUIRED. PROVIDE COLD WATER SUPPLY AND WATER LINES AS REQUIRED FOR NEW TOILET. DECON. GENERAL NOTES 1. REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET T111. 2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR SALVAGED FOR LANDLORD. FOR ALL ITEMS DETERMINED FOR REMOVAL, REFER TO THE RECYCLING INSTRUCTIONS. 3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED. 4. SALVAGE REMOVED LIGHT FIXTURES AND HVAC DIFFUSERS FOR REUSE WHERE POSSIBLE. SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. REFER TO RECYCLING INSTRUCTIONS FOR FIXTURES THAT WILL NOT BE SALVAGED. 5. SALVAGE REMOVED DOORS FOR REUSE WHERE POSSIBLE. SEE DOOR SCHEDULE FOR MORE INFORMATION. REFER TO RECYCLING INSTRUCTIONS FOR DOORS THAT WILL NOT BE SALVAGED. ELECTRIC OUTLET(S) EXISTING TO BE REMOVED EXISTING TO REMAIN WALL DOOR AND FRAME WALL DOOR AND FRAME SUPPLY AIR DIFFUSERS LIGHT FIXTURE, FLUORESCENT, 2'x4' CEILING GRID AND TILES, 2'x2' PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL LEGEND RECYCLING INSTRUCTIONS SALVAGE FOR RELOCATION METALS ONLY RECYCLING BIN: 1. CONTACT WASTE HAULER TO ORDER TRASH DUMPSTER(S) AS REQUIRED AND (1) "METALS ONLY" RECYCLING BIN FOR THE DEMOLITION PORTION OF PROJECT ONLY. SIZE OF "METALS ONLY" BIN IS DETERMINED BY THE AMOUNT OF DEMOLITION (10-40 YARD CONTAINERS AVAILABLE). 2. DRYWALL MUST BE REMOVED FROM ALL METAL STUDS PRIOR TO PLACING IN "METALS ONLY" BIN. ANY ADDED LABOR COST WILL BE COVERED BY METAL CREDITS RECEIVED FROM WASTE HAULER. 3. WASTE HAULER WILL APPLY CREDIT FOR METALS OBTAINED IN "METALS ONLY" BIN TOWARDS CONTRACTORS OVERALL INVOICE. 4. DATA/DIVERSION REPORTS ARE NOT REQUIRED NOR ANY LEED PROCESSES OR PAPERWORK. APPROVED METAL ITEMS: 5. METAL STUDS, DOOR FRAMES, DOOR HARDWARE, CEILING GRID, LIGHT BOX FIXTURES, METAL CABINETS, METAL PLUMBING FIXTURES, ELECTRICAL AND DATA WIRING/CONDUIT, HVAC COMPONENTS, AND ELECTRICAL/DATA/SWITCH BOXES CARPET RECYCLING: 6. CONTACT KRUSE CARPET RECYCLING TO SCHEDULE PICK UP OF ALL CARPET BEING REMOVED (BROADLOOM AND CARPET TILE). COORDINATE REQUIREMENTS AND PICK UP WITH SUSAN SHAFER (317) 337-1950. DEMOLITION CREW IS NOT RESPONSIBLE FOR KRUSE SERVICE FEES AND WILL ALSO RECOGNIZE A SAVINGS BY NO LONGER PAYING HAULING/TIPPING FEES ON CARPET DISPOSAL WITH WASTE HAULER. 7. KRUSE WILL PROVIDE AN ON-SITE BIN ON DAYS REQUIRED. DEMOLITION CREW IS TO PLACE CARPET DIRECTLY INTO BIN; DOES NOT NEED TO BE PALLETIZED. CONTRACTOR IS RESPONSIBLE FOR KEEPING BINS CLEAN AND DRY AS TO NOT CONTAMINATE CONTENTS. 8. KRUSE PICK UP AND RECYCLING FEES ARE TO BE PAID THROUGH SCHOTT DESIGN'S "NO COST ADD PROGRAM". CARPET MANUFACTURER IS TO PAY $1.00 PER SQUARE YARD FOR CARPET RECYCLING BY REDUCING PRICE OF CARPET MATERIAL BY $1.00. FLOORING CONTRACTOR IS RESPONSIBLE FOR DEDUCTING MATERIAL PRICE AND PAYING $1.00 PER SQUARE YARD TO KRUSE. CONTACT EMILY HILLYER (317) 762-7840 AT SCHOTT DESIGN FOR ANY QUESTIONS REGARDING THE RECYCLING PROCESSES. schottXchange: 9. CONTACT schottXchange BEFORE DEMOLITION OF ITEMS THAT CANNOT BE RECYCLED OR SALVAGED FOR LANDLORD. schottXchange CONSIDERS: DOORS, GLASS WINDOW SYSTEMS, CABINETS, DECORATIVE LIGHTS, AND FURNITURE. IF ITEMS ARE ACCEPTED FOR OUR INVENTORY, COORDINATE PICKUP AFTER DEMOLITION WITH EMILY HILLYER (317) 762-7840 AT schottXchange AT NO COST TO THE PROJECT. A141 4 W2 W2 04/19/21