HomeMy WebLinkAboutA111 Deconstruction and ArchitecturalUP
DN
UP
DN
OPEN OFFICE
STG. 419
424
RR
418
MULTIPURPOSE
ROOM
423
STORAGE
433
8'-5"
5'-5"
(HOLD)
7'-11" 9'-11"
7'-11"
115°
ALIGN
FE
WALL
THICKNESS
PRE-FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
TYPICAL WALL TYPE
METAL STUD
EXISTING WINDOW
MULLION
EQUAL & ARCHITECTURAL
FLOOR PLAN
A111
AREA NOT IN CONTRACT ARCHITECTURAL PLAN
AREA OF WORK
WALL
DOOR AND FRAME
(SEE DOOR SCHEDULE)
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT WINDOW / SIDELIGHT
ARCHITECTURAL LEGEND
PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL
DEMISING WALL WITH SECURITY MESH
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" SOUND BATT INSULATION
EACH SIDE OF WALL ABOVE CEILING;
PROVIDE METAL SECURITY MESH ON TOP OF
WALL ABOVE CEILING TO DECK
W1 WALL WITH INSULATION
35
8 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5
8" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
W2
WALL TYPES
W1
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
DATE DESCRIPTION
ISSUE
03.23.2021 REVIEW SET
03.25.2021 PERMIT SET
REVISIONS
MARK DATE DB DESCRIPTION
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
AMERICAN PAIN
CONSORTIUM EXPANSION
ONE PENN MARK | SUITE 400
11595 N MERIDIAN, CARMEL IN 46032
EH JR
2020.299
4TH FLOOR
N
0 2' 4' 8' 16'
DECONSTRUCTION PLAN
REMOVE EXISTING CABINETRY AND COUNTERTOP.
REMOVE EXISTING SINK. NO SERVICE SINKS ARE BEING REMOVED.
REMOVE EXISTING WALL AT THIS LOCATION.
REMOVE PLASTIC LAMINATE WINDOW SILL AT THIS LOCATION;
PREPARE DRYWALL SILL FOR NEW FINISHES AS REQUIRED.
DECON. PLAN NOTES
AREA NOT IN CONTRACT
AREA OF WORK
DECONSTRUCTION
ARCH. GENERAL NOTES
ARCH. PLAN NOTES
TYP.
A111
1
0 2' 4' 8' 16' NOT TO SCALE
WALL AT MULLION DETAIL
A111
1
1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
3. ALL EXISITING WINDOW BLINDS THROUGHOUT SUITE ARE TO BE
CLEANED. CONFIRM ALL BLINDS ARE IN GOOD, WORKING
ORDER. REPAIR, OR REPLACE, ANY DAMAGED OR MISSING
BLINDS AS REQUIRED.
ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
NEW FIRE EXTINGUISHER AND SEMI-RECESSED CABINET TO BE
PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE
EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10.
SEMI-RECESSED CABINET TO BE PAINTED TO MATCH ADJACENT
WALL.
PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
CONSTRUCT NEW CORRIDOR WALL TO MATCH ADJACENT
CORRIDOR WALL CONSTRUCTION. CONTRACTOR TO CONFIRM IN
FIELD ALL CONDITIONS.
PROVIDE 8'-0" H X 13'-5" W,
3
8" TEMPERED GLASS IN TIMELY FRAME,
PAINTED TO MATCH SUITE STANDARD. PROVIDE MULTIPLE, EQUAL
SIZED PANES WITH BUTT-GLAZE TRANSITION AS REQUIRED. PROVIDE
CLEAR POLYMER STRIPS AT TRANSITION BETWEEN PANELS. NO
SILICONE SEALANT PERMITTED.
PROVIDE (5) 18"D WHITE MELAMINE SHELVES ON HEAVY DUTY KV
BRACKETS AND STANDARDS AT THIS LOCATION.
_______________________________________________________________
PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL
AUTOMATIC SHUTOFF VALVES AS REQUIRED.
PROVIDE COLD WATER SUPPLY AND WATER LINES AS REQUIRED
FOR NEW TOILET.
DECON. GENERAL NOTES
1. REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET T111.
2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE
CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR
SALVAGED FOR LANDLORD. FOR ALL ITEMS DETERMINED FOR
REMOVAL, REFER TO THE RECYCLING INSTRUCTIONS.
3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN
ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW
FINISHES AS REQUIRED.
4. SALVAGE REMOVED LIGHT FIXTURES AND HVAC DIFFUSERS FOR
REUSE WHERE POSSIBLE. SEE REFLECTED CEILING PLAN FOR MORE
INFORMATION. REFER TO RECYCLING INSTRUCTIONS FOR
FIXTURES THAT WILL NOT BE SALVAGED.
5. SALVAGE REMOVED DOORS FOR REUSE WHERE POSSIBLE. SEE
DOOR SCHEDULE FOR MORE INFORMATION. REFER TO
RECYCLING INSTRUCTIONS FOR DOORS THAT WILL NOT BE
SALVAGED.
ELECTRIC OUTLET(S)
EXISTING TO BE REMOVED EXISTING TO REMAIN
WALL
DOOR AND FRAME
WALL
DOOR AND FRAME
SUPPLY AIR DIFFUSERS
LIGHT FIXTURE,
FLUORESCENT, 2'x4'
CEILING GRID AND
TILES, 2'x2'
PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL
LEGEND RECYCLING INSTRUCTIONS
SALVAGE FOR
RELOCATION
METALS ONLY RECYCLING BIN:
1. CONTACT WASTE HAULER TO ORDER TRASH DUMPSTER(S) AS
REQUIRED AND (1) "METALS ONLY" RECYCLING BIN FOR THE
DEMOLITION PORTION OF PROJECT ONLY. SIZE OF "METALS ONLY"
BIN IS DETERMINED BY THE AMOUNT OF DEMOLITION (10-40 YARD
CONTAINERS AVAILABLE).
2. DRYWALL MUST BE REMOVED FROM ALL METAL STUDS PRIOR TO
PLACING IN "METALS ONLY" BIN. ANY ADDED LABOR COST WILL BE
COVERED BY METAL CREDITS RECEIVED FROM WASTE HAULER.
3. WASTE HAULER WILL APPLY CREDIT FOR METALS OBTAINED IN
"METALS ONLY" BIN TOWARDS CONTRACTORS OVERALL INVOICE.
4. DATA/DIVERSION REPORTS ARE NOT REQUIRED NOR ANY LEED
PROCESSES OR PAPERWORK.
APPROVED METAL ITEMS:
5. METAL STUDS, DOOR FRAMES, DOOR HARDWARE, CEILING GRID,
LIGHT BOX FIXTURES, METAL CABINETS, METAL PLUMBING FIXTURES,
ELECTRICAL AND DATA WIRING/CONDUIT, HVAC COMPONENTS,
AND ELECTRICAL/DATA/SWITCH BOXES
CARPET RECYCLING:
6. CONTACT KRUSE CARPET RECYCLING TO SCHEDULE PICK UP OF
ALL CARPET BEING REMOVED (BROADLOOM AND CARPET TILE).
COORDINATE REQUIREMENTS AND PICK UP WITH SUSAN SHAFER
(317) 337-1950. DEMOLITION CREW IS NOT RESPONSIBLE FOR
KRUSE SERVICE FEES AND WILL ALSO RECOGNIZE A SAVINGS BY
NO LONGER PAYING HAULING/TIPPING FEES ON CARPET
DISPOSAL WITH WASTE HAULER.
7. KRUSE WILL PROVIDE AN ON-SITE BIN ON DAYS REQUIRED.
DEMOLITION CREW IS TO PLACE CARPET DIRECTLY INTO BIN; DOES
NOT NEED TO BE PALLETIZED. CONTRACTOR IS RESPONSIBLE FOR
KEEPING BINS CLEAN AND DRY AS TO NOT CONTAMINATE
CONTENTS.
8. KRUSE PICK UP AND RECYCLING FEES ARE TO BE PAID THROUGH
SCHOTT DESIGN'S "NO COST ADD PROGRAM". CARPET
MANUFACTURER IS TO PAY $1.00 PER SQUARE YARD FOR CARPET
RECYCLING BY REDUCING PRICE OF CARPET MATERIAL BY $1.00.
FLOORING CONTRACTOR IS RESPONSIBLE FOR DEDUCTING
MATERIAL PRICE AND PAYING $1.00 PER SQUARE YARD TO KRUSE.
CONTACT EMILY HILLYER (317) 762-7840 AT SCHOTT DESIGN FOR ANY
QUESTIONS REGARDING THE RECYCLING PROCESSES.
schottXchange:
9. CONTACT schottXchange BEFORE DEMOLITION OF ITEMS THAT
CANNOT BE RECYCLED OR SALVAGED FOR LANDLORD.
schottXchange CONSIDERS: DOORS, GLASS WINDOW SYSTEMS,
CABINETS, DECORATIVE LIGHTS, AND FURNITURE. IF ITEMS ARE
ACCEPTED FOR OUR INVENTORY, COORDINATE PICKUP AFTER
DEMOLITION WITH EMILY HILLYER (317) 762-7840 AT
schottXchange AT NO COST TO THE PROJECT.
A141
4
W2
W2
04/19/21