Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Floor Plan
B C 2 1 1.2 1.1 A A2 2 17' - 5 1/2"3"60' - 2" VCR 1 106 VCR 2 105 BREAK ROOM 120 WOMENS 117 MENS 116 ELECTRICAL 115 ATM/NER 102 24 HOUR ZONE 100 MAIL 122 VESTIBULE 101 VCR 3 10327' - 2"31' - 7"7' - 8"1 1 2 5 5 NER RACK 6 6 77 ACTIVE LEAFACTIVE LEAFACTIVE LEAFPUSH PLATE PUSH PLATE PUSH PLATE PUSH PLATE PUSH PLATE 103 105A 102 101B 111 120 121 116B 106 107 105B 100 101A PUSH PLATE 2 DAY 1 ATM ADA COMPLIANT ATMS DRIVE THRU 126 7' - 0"13' - 10"6"10' - 0"6"9' - 3"8' - 9"1' - 3"8' - 9"10' - 0"10' - 0"10' - 0"10' - 0" 7' - 6"7' - 6"4"7' - 6"4"7' - 6"4"1' - 6"8' - 0"1' - 6"8' - 0"1' - 6"5' - 10"6' - 2"1' - 4"6' - 2"JANITOR 118 5' - 6" MW08A LOBBY 107 OPEN OFFICE 110 CONFERECE 109 OFFICE 111 OFFICE 112 CORRIDOR 113 CORRIDOR 114 VCR 4 104 WELLNESS 119 UNISEX 121 NER 123 STORAGE 124 COAT 125 COAT 108 2"6"2"6"2' - 5 1/2"A3 2 A2 1 A316' - 5 1/2"3"66' - 5"1' - 1 1/2"75' - 9 1/2"62' - 9"68' - 6"Indiana Cert. Nos. NO Cert. No. for IN. Reynolds, Smith and Hills, Inc. www.rsandh.com Indiana Cert. Nos. NO Cert. No. for IN. Reynolds, Smith and Hills, Inc. www.rsandh.com CHECKED BY: DRAWN BY: DATE ISSUED: REVISIONS SHEET TITLE DESIGNED BY: THESE DRAWINGS ARE NOT APPROVED UNLESS SIGNED AND SEALED BELOW. KEY NOTES SHEET NOTES CONSULTANTS 670 Morrison Road, Suite 260 Gahanna, Ohio 43230 614-501-6331 FAX 614-501-6341 © 2020 RS&H, INC. AEP PROJECT NUMBER BULLETIN:01-2021 SHEET NUMBER DESIGN DEVELOPMENT 4/14/2021 10:55:08 AMBIM 360://5240234000_BAC IN Carmel GU AC ML CoLo/BAC IN Carmel GU AL ML CoLo A 20.rvt 04/12/21 KK GC CONSTRUCTION PLAN KCC 5240234000 11505 N. ILLINOIS STREET CARMEL, IN 46032 A13/16" = 1'-0"A1 1 CONSTRUCTION PLANN 0 4'8'16' 1 DASHED LINE INDICATES OVERHEAD CANOPY CONSTRUCTION, RE: EXTERIOR ELEVATIONS, STRUCUTRAL SHEETS 2 PROVIDE FIRE-RATED 3/4" PLYWOOD BACKBOARD IN THIS ROOM, H = 8'-0" 3 LADDER TO ROOF HATCH ABOVE - SEE DETAIL X/AXXX 4 ROOF HATCH ABOVE - SEE DETAIL X/AXXX 5 ATM AND SURROUND, REFER TO BANK APPROVED CUT SHEETS FOR INSTALLATION INSTRUCTIONS 6 ACCESSIBLE ATM SHALL COMPLY WITH AMERICAN DISABILITY ACT 2010 7 OFFICE STOREFRONTS WITH DISTRACTION MARKER.GLASS AND ALUMINUIM SYSTEM OWNER PROVIDED AND INSTALLED. A. ALL PARTITIONS TO BE TYPE "A2", UNLESS OTHERWISE NOTED. REFER TO SHEET G004. B. FOR ADDITIONAL GENERAL NOTE, LEGENDS AND SCHEDULES REFERENCE "G" SERIES SHEETS. C. UNLESS OTHERWISE NOTED, LOCATE HINGE SIDE OF ALL DOORS 4" FROM ADJACENT PERPENDICULAR PARTITION. D. REFER TO DRAWING A601 FOR BANKING EQUIPMENT, VERIFY ALL EQUIPMENT WITH VENDOR. E. CONTRACTOR SHALL PROVIDE BLOCKING FOR ALL EQUIPMENT AND ACCESSORIES MOUNTED ON WALLS. XFLOOR PLAN LEGEND x SPACE DEMISING WALL KEYNOTES NO. DESCRIPTION DATE