HomeMy WebLinkAboutA211 Door Schedule and InteriorEXIST
4"V.
EXIST
4"W.
2"W.
F.F.
2"W.
2"W.
SINK
TO
BUILDING
DRAIN
F.F.
11
2"V.
CLG.
11
2"V.
CLG.
TO EXISTING
STACK
NOTE: REFER TO FLOOR PLAN
AND CASEWORK ELEVATION(S)
FOR SINK LOCATION(S)
F1
6'-6"
2" 3'-0"
REFER TO DOOR SCHED. 2"
2" 3'-0" 2"
1
4" TEMPERED
GLASS
F2
5'-6"
2" 3'-0"
REFER TO DOOR SCHED. 2"
2" 2'-0" 2"
1
4" TEMPERED
GLASS
F3
F4
10'-2"
2" 3'-0"
REFER TO DOOR SCHED. 2"
2" 6'-8" 2"
PROVIDE NEW, EQUAL SIZED,
1
2" TEMPERED GLASS PANELS
IN TIMELY FRAME TO MATCH
SUITE STANDARD. PROVIDE
CLEAR POLYMER STRIPS AS
REQUIRED AT BUTT-GLAZE;
NO SILICONE
SEALANT PERMITTED.
PROVIDE CUSTOM VINYL
FILM ON GLASS
COMPONENTS; EXACT
DESIGN: TBD
EQ. EQ.
F5
10'-7"
2" 3'-0"
REFER TO DOOR SCHED. 2"
2" 7'-1" 2"
PROVIDE NEW, EQUAL SIZED,
1
2" TEMPERED GLASS PANELS
IN TIMELY FRAME TO MATCH
SUITE STANDARD. PROVIDE
CLEAR POLYMER STRIPS AS
REQUIRED AT BUTT-GLAZE;
NO SILICONE
SEALANT PERMITTED.
PROVIDE CUSTOM VINYL
FILM ON GLASS
COMPONENTS; EXACT
DESIGN: TBD
EQ. EQ.
F6
5'-2"
2" 3'-0"
REFER TO DOOR SCHED. 2"
2" 1'-8" 2"
1
4" TEMPERED
GLASS
DELETED FROM SCOPE
REFER TO DOOR SCHED.
D1
3'-0"
1'-0" 8"
7" 7"
REFER TO DOOR SCHED.
3'-0"
D2 D3
1
4" TEMPERED
GLASS, WOOD
FLUSH BEAD
STAINED TO
MATCH DOOR
FULL HEIGHT
3'-0"
PROVIDE ONE PULL ON
EACH SIDE OF DOOR
(TOTAL COUNT 2), AS
NOTED
4" STAINLESS STEEL
TOP RAIL
1/2" TEMPERED GLASS
4" STAINLESS STEEL
BOTTOM RAIL
3'-0"
25" DEEP PLASTIC LAMINATE
(PL1) COUNTERTOP WITH NO
BACKSPLASH; SCRIBE COUNTER
TO WALL AND PROVIDE BEAD
OF CLEAR SILICONE AT
COUNTER TO WALL TRANSITION.
PROVIDE CONCEALED/IN-WALL
SUPPORTS AS REQUIRED.
DESIGN INTENT IS FOR
SUPPORTS TO BE FULLY
CONCEALED.
4'-5"
2'-0" 1"
EXISTING
COLUMN
(4) 18" DEEP ADJUSTABLE WHITE
MELAMINE SHELVES ON HEAVY
DUTY KV BRACKETS AND
STANDARDS
VINYL BASE (VB1) AS
SCHEDULED
DOOR SCHEDULE
# DIMENSIONS DOOR FRAME HARDWARE REM.
01
02 R1
03 R1
04A
04B
06 R1
08 R2
09
11 R1
14
15 DELETED FROM SCOPE
DOOR SCHEDULE
INTERIOR DETAILS
A211
TYPICAL ALL SINGLE LOCATIONS,
CL CLOSER
CH COAT HOOK
CR CARD READER BY TENANT (N.I.C.)
DB DEADBOLT
DL DUMMY LEVER
EL ELECTROMAGNETIC LOCK (PER IBC 2012)
ES ELECTRIC STRIKE BY TENANT (N.I.C.)
FP FOOT PULL - STEP N PULL HANDS FREE DOOR OPENER SNPE-B
H HOLD OPEN
KP KICK PLATE
KS KICK STOP
OL OFFICE LOCKSET
PH PANIC HARDWARE
PL PRIVACY LOCKSET
PP PUSH/PULL - PROVIDE ONE POST MOUNT PULL ON EACH SIDE OF DOOR
(TOTAL COUNT 2), ROCKWOOD #RM3302, 628 CLEAR ANODIZED FINISH.
PS PASSAGE LATCHSET
PV PIVOT HINGE
RL ROLLER LATCHES
SL STOREROOM LOCKSET
TS TOP STRIKES
HARDWARE LEGEND
DATE DESCRIPTION
ISSUE
12.17.2020 REVIEW SET
12.21.2020 PERMIT SET
03.16.2021 ADDENDUM SET
03.29.2021 CONSTRUCTION SET
REVISIONS
MARK DATE DB DESCRIPTION
03.17.2021 JR REV1
2 03.29.21 ACM REV2
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
AMERICAN HEALTH +
WELNESS
11555 NORTH MERIDIAN, SUITE 530
CARMEL, IN 46032
ACM ACM/JR
2020.242
5TH FLOOR
1
DOOR/FRAME TYPES
0 1' 2' 4'
ELEVATION - WELCOME 501
A211
2
NOT TO SCALE
RISER DIAGRAM
A211
1
R1. ALTER DOOR AS REQUIRED TO MATCH DOOR STYLE "D3".
R2. PROVIDE 24"X24" METAL LOUVER IN DOOR, PAINTED TO MATCH
DOOR FRAME. DOOR TO HAVE 1" UNDERCUT THRESHOLD FOR
ADDITIONAL AIR FLOW.
R3. DELETED.
R4. DELETED.
REMARKS
DOOR/FRAME NOTES
1. REUSE DOORS FROM DECONSTRUCTION WHERE POSSIBLE; TOUCH UP
EXISTING DOOR STAIN AS REQUIRED. PROVIDE NEW BUILDING STANDARD
DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS TO
MATCH EXISTING. PRE-MACHINE NEW DOORS FOR CYLINDRICAL
LOCKSETS.
2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS. REUSE
EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW
DOOR HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD.
PROVIDE ADA ACCESSIBLE LEVER HANDLES ON NEW LOCK AND
LATCHSETS.
3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED. REUSE
EXISTING FROM DEMOLITION WHERE POSSIBLE. IF FRAMES ARE NOT BEING
REPAINTED, TOUCH UP EXISTING FRAMES TO BE REUSED.
4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL
CORNERS UNLESS OTHERWISE NOTED ON PLAN.
5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND
LOCKSETS.
6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION,
PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED
ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES.
ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE
INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS.
7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS:
· 7'-0" HT. TO HAVE 3 HINGES
· GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES
· FINISH TO MATCH HARDWARE SET
8. PROVIDE (1) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE
NOTED.
9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR
UNLESS OTHERWISE NOTED. PROVIDE BLOCKING BEHIND WALL STOP.
TYPE MATERIAL FINISH TYPE MATERIAL FINISH
3'-0"x8'-0"x1
3
4" (PAIR) D1 HERCULITE GLASS SYSTEM DRYWALL WRAPPED OPENING EL, CR, CL, PP
3'-0"xFULL HEIGHT -- -- -- F1 TIMELY PT4 PS
-- --
PS
NEW
SWING
LH,RH
LH
--
3'-0"xFULL HEIGHT LH -- -- -- F2 TIMELY PT4
-- -- -- -- -- -- -- --
CR, ES, SL, CL
RELOCATED
RELOCATED
RELOCATED
EXISTING
RELOCATED
EXISTING
--
--
LH
--
RH
--
0 1' 2' 4'
ELEVATION - REJUVENATE 509
A211
3
0 1' 2' 4'
ELEVATION - STORAGE 507
A211
5
0 1' 2' 4'
ELEVATION - REJUVENATE 509
A211
4
EXISTING -- --
--
-- -- -- F4 TIMELY PT4
-- -- -- -- -- PT4
-- -- -- -- -- PT4
-- -- -- -- -- PT4
-- -- -- F5 TIMELY PT4
3'-0"xFULL HEIGHT
3'-0"xFULL HEIGHT
PS
SL, CL
PS
PS
DELETED FROM SCOPE
1
EXISTING
EXISTING
--
--
1
-- -- -- --
1
1
1
1
DELETED FROM SCOPE DELETED FROM SCOPE
04/20/21