HomeMy WebLinkAboutE111 ElectricalREFRIG
BY
TENANT
MICRO
OPEN OFFICE
505
OPEN OFFICE
512
WELCOME
501
OFFICE SUPPLIES +
STORAGE
514 STUDIO
511
TV
TV
TV
TV
TOWN HALL
503
TV
TEAM ROOM
504
TV
BRAINSTORM
502
6x8
6x8
6x8
6x8
SERVER
508
6x8
6x8
6x8
6x8
6x8
6x8
6x8
STORAGE
507
6x6
6x6 6x6
6x6 6x6
6x6
REFRIG
BY
TENANT
DW
6x8
6x8
MICRO
WORKSHOP
506
6x6 6x6
TV
REJUVENATE
509
NEIGHBORHOOD
510
+76"
+76"
+42"
+60"
+60"
+60"
+60"
+60"
+60"
+60"
+60"
+TBD
+TBD +TBD
+TBD
J
J
J
J
J
J
DED
DED
+24" DED
J J
+44" DED
+44"
+44"
+42"
+42" DED
+42"
+30"
DED
GFCI
GFCI
ICE
DED
DED
COPY
515
ELECTRICAL PLAN
E111
PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE
WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS.
COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED.
PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION
WITH TENANT'S FURNITURE VENDOR.
PROVIDE DEDICATED POWER OUTLET FOR TENANT'S MICROWAVE, COORDINATE EXACT HEIGHT WITH
TENANT.
PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN.
COORDINATE EXACT LOCATION WITH TENANT.
PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND DATA.
COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE
SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING.
PROVIDE POWER AT THIS LOCATION FOR TENANT PROVIDED DISHWASHER AND/OR ICE MAKER.
COORDINATE EXACT SERVER/IT REQUIREMENTS WITH TENANT.
CONTRACTOR IS TO ENSURE THAT ALL EXISTING OUTLETS IN THIS LOCATION ARE GFCI.
PROVIDE DIRECT HDMI/VGA CONDUIT CONNECTION FROM FLOOR CORE POKE THRU DEVICE TO WALL
MOUNTED MONITOR(S) OR CEILING MOUNTED PROJECTOR.
REUSE EXISTING JUNCTION BOX AND DATA AT THIS LOCATION. IF NOT POSSIBLE, PROVIDE NEW AS
DESCRIBED IN NOTE E03.
NOT USED.
PLAN NOTES
ELECTRICAL PLAN
LEGEND
DATE DESCRIPTION
ISSUE
12.17.2020 REVIEW SET
12.21.2020 PERMIT SET
03.16.2021 ADDENDUM SET
03.29.2021 CONSTRUCTION SET
REVISIONS
MARK DATE DB DESCRIPTION
03.17.2021 JR REV1
2 03.29.21 ACM REV2
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
AMERICAN HEALTH +
WELNESS
11555 NORTH MERIDIAN, SUITE 530
CARMEL, IN 46032
ACM ACM/JR
2020.242
5TH FLOOR
N
1
0 2' 4' 8' 16'
1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL
NEW DEVICES AND FACE PLATES TO MATCH EXISTING. PROVIDE
SEPARATE PRICE TO REPLACE ALL EXISTING TO WHITE.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. CONTRACTOR TO PROVIDE GFCI OUTLET FOR WATER HEATER AND
AUTOMATIC SHUTOFF VALVES AS REQUIRED.
5. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
GENERAL NOTES
DED
POWER OUTLET, DUPLEX
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
POWER OUTLET, DUPLEX
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
DEDICATED CIRCUIT
DATA/COMMUNICATION
OUTLET (PROVIDE BOX
AND PULL STRING ONLY)
DATA/COMMUNICATION
OUTLET
GFCI GROUND FAULT CIRCUIT
INTERRUPT OUTLET
HEIGHT OF ELECTRICAL
OR DATA DEVICE
J
+42"
AREA NOT IN CONTRACT
AREA OF WORK
1
1
1
1
1
1
04/20/21