HomeMy WebLinkAboutL100 Life Safety PlanREFRIG BY TENANT OPEN OFFICE 505 OPEN OFFICE 512 WELCOME 501 x OFFICE SUPPLIES + STORAGE 514 12'-9" 4'-10" x STUDIO 511 15'-9" 16'-5" x TOWN HALL 503 12'-6" 21'-1" x TEAM ROOM 504 25'-6" 16'-1" x BRAINSTORM 502 15'-6" 11'-10" 6x8 6x8 6x8 6x8 x SERVER 508 3'-5" 8'-3" 6x8 6x8 6x8 6x8 6x8 6x8 6x8 x STORAGE 507 12'-11" 8'-4" 6x6 6x6 6x6 6x6 6x6 6x6 REFRIG BY TENANT DW 6x8 6x8 MICRO x WORKSHOP 506 13'-0" 10'-8" 6x6 6x6 REJUVENATE 509 NEIGHBORHOOD 510 FE EL FE ELN ELN ELN ELN ICE COPY 515 LIFE SAFETY PLAN L100 LIFE SAFETY PLAN DATE DESCRIPTION ISSUE 12.17.2020 REVIEW SET 12.21.2020 PERMIT SET 03.16.2021 ADDENDUM SET 03.29.2021 CONSTRUCTION SET REVISIONS MARK DATE DB DESCRIPTION 03.17.2021 JR REV1 2 03.29.21 ACM REV2 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY AMERICAN HEALTH + WELNESS 11555 NORTH MERIDIAN, SUITE 530 CARMEL, IN 46032 ACM ACM/JR 2020.242 5TH FLOOR N 1 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. LIFE SAFETY NOTES L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. REPLACE ALL EXISTING EXIT SIGNS WITH NEW, EDGE LIT LED EXIT SIGNS. EXISTING FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. L3. RELOCATE EXISTING SPRINKLER HEADS TO FIT NEW WALL LAYOUT; PROVIDE NEW AS REQUIRED. SPRINKLERS TO BE LOCATED PER FIRE PROTECTION CODE. GENERAL NOTES 0 4' 8' 16' EXISTING ELECTRICAL PANEL LOCATION EXISTING EXIT EP EX LEGEND FIRE EXTINGUISHER EXIT SIGN EMERGENCY LIGHT FE - BUILDING STAIR LOCATION AREA NOT IN CONTRACT AREA OF WORK TRAVEL DISTANCE SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACE TOTAL BUILDING AREA TOTAL PROJECT AREA CHANGE OF OCCUPANCY CLASS? OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD NO OCCUPANCY CLASSIFICATION B(USINESS) GEN. OFFICE SF 100 NUMBER OF EXITS REQUIRED: 2 PROVIDED: 2 SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 TOTAL AREA ON THE FLOOR SF SF/FLOOR X STORIES SF SF 19,568 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A = TOTAL OCCUPANTS IN PROJECT AREA 66 CODE SUMMARY PREVIOUS USE OF SPACE B(USINESS) ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN) BUILT BEFORE 1978? NO 6,572 6,752 19,568 5 97,840 66 - LED EDGE LIT BUILDING CONSTRUCTION TYPE II-B EP EX EX BUSINESS BUSINESS BUSINESS TRAVEL DISTANCE = 154' 04/20/21