HomeMy WebLinkAboutA111 Architectural Floor PlanWALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT METAL STUD EXISTING WINDOW MULLION EQUAL REFRIG BY TENANT MICRO OPEN OFFICE 505 OPEN OFFICE 512 WELCOME 501 OFFICE SUPPLIES + STORAGE 514 STUDIO 511 TV TV TV TV TOWN HALL 503 TV TEAM ROOM 504 TV BRAINSTORM 502 SERVER 508 STORAGE 507 REFRIG BY TENANT DW MICRO WORKSHOP 506 TV REJUVENATE 509 NEIGHBORHOOD 510 13'-5" 6'-10" 5'-3" 9'-4" 3'-6" 2'-3" 11'-10" 10'-11" 102° 12'-2" 12'-3" 21'-1" 9'-0" 7'-2" FE 151° 124° FE 15'-11" ALIGN ICE COPY 515 78° 3'-11 4 " ARCHITECTURAL FLOOR PLAN A111 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE NEW 24"DEEP PLASTIC LAMINATE (PL1) COUNTERTOP @36" AFF TO FIT WIDTH OF WALL WITH NO BACKSPLASH. SCRIBE COUNTER TO WALL. PROVIDE SUPPORT COUNTER AS REQUIRED WITH RAKKS EH-1818-FM BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. NEW FIRE EXTINGUISHER AND SEMI-RECESSED CABINET TO BE PROVIDED AND INSTALLED BY CONTRACTOR. UTILIZE SALVAGED RECESSED CABINET AND FIRE EXTINGUISHER WHERE POSSIBLE. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. EXISTING FIRE EXTINGUISHER TO REMAIN IF IN PROPER WORKING ORDER. CONTRACTOR TO CONFIRM THAT EXISTING FIRE EXTINGUISHER IS INSTALLED ACCORDING TO NFPA 10. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W1". IF NOT, ALTER EXISTING WALL AS REQUIRED TO MATCH "W1". NEW WALL CONSTRUCTION TO MATCH EXISTING ADJACENT WALL CONSTRUCTION, CONTRACTOR TO CONFIRM IN FIELD ALL EXISTING CONDITIONS. PROVIDE 54" DEEP SOLID SURFACE COUNTERTOP (SS1) AT 42" A.F.F. WITH MITREFOLDED WATERFALL EDGE ON EAST AND WEST SIDES OF COUNTERTOP. ISLAND TO BE CENTERED ON WALL BELOW, PROVIDE CONCEALED/IN-WALL SUPPORTS AS REQUIRED. DESIGN INTENT IS FOR SUPPORTS TO BE FULLY CONCEALED; GENERAL CONTRACTOR TO ENSURE DESIGN INTENT IS MET. REFER TO ELEVATION FOR ADDITIONAL INFORMATION. DESIGN INTENT IS TO INSTALL SALVAGED WOOD CABINETS FROM DEMOLITION WITH NEW COUNTERTOPS AT THIS LOCATION. CONTRACTOR TO ENSURE THAT COUNTERTOP FINISHED HEIGHT IS AT 34" A.F.F. ALTER TOE KICK AS REQUIRED. PROVIDE NEW WOOD CABINETS TO MATCH AS REQUIRED TO FINISH LAYOUT AS INTENDED ON PLAN. PROVIDE (4) 18" DEEP WHITE MELAMINE ADJUSTABLE SHELVES ON HEAVY DUTY KV BRACKETS AND STANDARDS. CONFIRM THAT EXISTING DEMISING WALL MATCHES WALL TYPE "W4". IF NOT, ALTER EXISTING WALLS AS REQUIRED TO MATCH "W4". COORDINATE WITH TENANT ON EXACT LAYOUT OF WOOD CABINETRY RELOCATED FROM DEMOLITION. PURCHASE ADDITIONAL CABINETRY AS NEEDED TO COMPLETE LAYOUT. ENSURE THAT TOP OF COUNTERTOP IS AT 34" AFF TO MEET ADA REQUIREMENTS. PREP CABINETS TO RECEIVE PAINT (PT5). ENSURE THAT PAINT FINISH IS SMOOTH AND "LIKE NEW CONDITION". _______________________________________________________________ PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. DESIGN INTENT IS TO UTILIZE EXISTING HOT AND COLD WATER AT THIS LOCATION. PROVIDE WATER LINE FOR COFFEE AND/OR REFRIGERATOR. CONFIRM LOCATION WITH TENANT. PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT PROVIDED DISHWASHER AT THIS LOCATION. PLAN NOTES ARCHITECTURAL PLAN WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL W1 DEMISING WALL WITH SECURITY MESH 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" SOUND BATT INSULATION EACH SIDE OF WALL ABOVE CEILING; PROVIDE METAL SECURITY MESH ON TOP OF WALL ABOVE CEILING TO DECK WALL WITH INSULATION 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W4 W2 WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. DATE DESCRIPTION ISSUE 12.17.2020 REVIEW SET 12.21.2020 PERMIT SET 03.16.2021 ADDENDUM SET 03.29.2021 CONSTRUCTION SET REVISIONS MARK DATE DB DESCRIPTION 03.17.2021 JR REV1 2 03.29.21 ACM REV2 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. 450 E. 96th Street Indianapolis, IN 46240 p: 317.387.1700 www.schottdesign.com PROJECT NUMBER PROJ. MGR DRAWN BY AMERICAN HEALTH + WELNESS 11555 NORTH MERIDIAN, SUITE 530 CARMEL, IN 46032 ACM ACM/JR 2020.242 5TH FLOOR N 1 0 2' 4' 8' 16' 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 3. CONTRACTOR TO REVIEW AND CONFIRM DAMAGED EXTERIOR WINDOWS WHERE SEALS NEED TO BE REPAIRED. COORDINATE WITH BUILDING LANDLORD ON EXACT LOCATIONS. 4. PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. CONFIRM ALL BLINDS ARE IN GOOD WORKING ORDER. REPAIR, OR REPLACE, ANY DAMAGED OR MISSING BLINDS AS REQUIRED. GENERAL NOTES NOT TO SCALE WALL AT MULLION DETAIL A111 1 W? AREA NOT IN CONTRACT AREA OF WORK TYP. A111 1 W3 A211 5 PARTIAL HEIGHT WALL 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO 3'-4""; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED; W3 1 1 1 1 DELETED FROM SCOPE 1 1 1 1 2 2 04/20/21