REFLECTED
CEILING PLAN
A121
CONTROL WELCOME 501, OPEN OFFICE 505, REJUVENATE 509, NEIGHBORHOOD 510 AND OPEN OFFICE 512 LIGHTING
WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED.
DELETED FROM SCOPE.
PROVIDE $500 PER PENDANT MATERIAL ALLOWANCE FOR DECORATIVE PENDANT LIGHT FIXTURE AT THIS LOCATION.
EACH PENDANT LIGHT TO HAVE SEPARATE DIMMER SWITCH. CONFIRM EXACT PLACEMENT WITH SDI AND TENANT AS
REQUIRED.
DELETED FROM SCOPE.
DELETED FROM SCOPE.
DELETED FROM SCOPE.
DELETED FROM SCOPE.
PLAN NOTES
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
ND
N
N3
D
3
EXIT LIGHT FIXTURE
LIGHT FIXTURE,
PENDANT
RECESSED LIGHT
FIXTURE, MATCH
EXISTING
LIGHT FIXTURE, 2'x4',
FLUORESCENT, PARABOLIC
RELOCATED DIFFUSER,
LAY-IN, 4"x4'
RELOCATED DIFFUSER,
LAY-IN, 2'x2'
CEILING GRID,
SUSPENDED, 2'x2'
NEW OR RELOCATED EXISTING TO REMAIN
SUSPENDED LINEAR LIGHT
FIXTURE, UP LIGHT/DOWN
LIGHT 2.5"W, LENGTH
VARIES, LED; SEPARATE
PRICE
LIGHT FIXTURE,
PENDANT
SUSPENDED LINEAR LIGHT
FIXTURE
EXIT LIGHT FIXTURE
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
CEILING GRID,
SUSPENDED, 2'x2'
DIFFUSER,
LAY-IN, 4"x4'
DIFFUSER,
LAY-IN, 2'x2'
GYPSUM BOARD CEILING
LIGHT FIXTURE, 2'x4',
FLUORESCENT, PARABOLIC
LEGEND
REFLECTED CEILING PLAN
RECESSED LIGHT
FIXTURE
DATE DESCRIPTION
ISSUE
12.17.2020 REVIEW SET
12.21.2020 PERMIT SET
03.16.2021 ADDENDUM SET
03.29.2021 CONSTRUCTION SET
REVISIONS
MARK DATE DB DESCRIPTION
03.17.2021 JR REV1
2 03.29.21 ACM REV2
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.com
PROJECT NUMBER
PROJ. MGR DRAWN BY
AMERICAN HEALTH +
WELNESS
11555 NORTH MERIDIAN, SUITE 530
CARMEL, IN 46032
ACM ACM/JR
2020.242
5TH FLOOR
N
1
0 2' 4' 8' 16'
EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE
MECHANICAL DIFFUSER RELOCATION
A121
1
*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
EXISTING VAV BOXES OR
HEAT PUMP AND MAIN SUPPLY
DUCTS TO REMAIN
RELOCATE DIFFUSERS &
FLEXDUCT IF REQUIRED
VAV /
HEAT PUMP
GYPSUM BOARD CEILING
EXPOSED TO DECK
A121
1
1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x2
AT 8'-8" A.F.F. TILES ARE 2x2 ACOUSTICAL REVEAL EDGE TILES. REPAIR ANY DAMAGED
GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING.
2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM DECONSTRUCTION
CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS
WHERE POSSIBLE TO CREATE UNIFORM LOOK.
3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC.
EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER
SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES
SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE
ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH
DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO
SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL
CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS
REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI.
5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH
ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE.
OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY
PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY
SENSORS IN OPEN AREAS AS REQUIRED.
6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE POSSIBLE, GANG
MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE
SHOWN ADJACENT ON PLAN. PROVIDE SEPARATE PRICE TO REPLACE ALL EXISTING
DEVICES AND FACEPLATES WITH WHITE.
7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE
DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF
ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF
THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL
PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES.
GENERAL NOTES
1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING
H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE
SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS
BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY
APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
MECHANICAL NOTES
AREA NOT IN CONTRACT
AREA OF WORK
PROVIDE SEPARATE PRICE FOR SOUND BOOTS ON ALL NEW AND EXISTING RETURN AIR GRILLS AT THIS LOCATION.
1
1
1
1
1
1
04/20/21