Loading...
HomeMy WebLinkAboutCover Sheet 1CHECKED DATE DRAWN CODE APPPDE CHK DES NO DATE REVISIONS AND RECORD OF ISSUE DRAWING NUMBERPROJECT REV AREADRN ANSI D 34x220 25/JUN/20 ISSUED FOR PERMITTING 1 11/FEB/21 ISSUED FOR PERMITTING 02/14/2017 04:16 PM 25/JUN/20 DESIGNER 1R J.P. MORGAN CHASE 13085 PETTIGRU DRIVE, CARMEL, IN 46032-4436 COVER PAGE 156701 : 33.75 kWp J.P. MORGAN CHASE 13085 Pettigru Drive CARMEL, IN 46032-4436 ASSESSOR'S #: 29-09-29-020-001.002-018 AUTHORITIES HAVING JURISDICTION BUILDING: CITY OF CARMEL ZONING: CITY OF CARMEL UTILITY: DUKE ENERGY/1326 DESIGN SPECIFICATIONS OCCUPANCY: B CONSTRUCTION: COMMERCIAL / INDUSTRIAL GROUND SNOW LOAD: 20 PSF WIND SPEED: 106 MPH DESIGN SPECIFICATIONS RISK CATEGORY: II SITE CLASS: D (DEFAULT) SEISMIC IMPORTANCE FACTOR: 1.0 SEISMIC DESIGN CATEGORY: B SS: 0.168 S1: 0.082 SDS: 0.18 SD1: 0.131 ANALYSIS PROCEDURE: NONSTRUCTURAL COMPONENTS DESIGN CODES & STANDARDS BUILDING: 2018 INTERNATIONAL BUILDING CODE (SEE NOTE 1) ELECTRICAL: 2008 NEC FIRE: 2018 INTERNATIONAL FIRE CODE (SEE NOTE 2) PROJECT INFORMATION IN-156701-G10 KPI KPI AT AT NRS NRS DRAWING INDEX DRAWING NUMBER SHEET TITLE G10 COVER PAGE G20 SITE PLAN E10 ELECTRICAL ROOF PLAN E20 THREE LINE DIAGRAM & BILL OF MATERIALS E21 ONE LINE DIAGRAM E30 PLACARDS REQUIRED STANDARD DRAWING INDEX DRAWING NUMBER SHEET TITLE SG10 COVER PAGE SG20 GENERAL NOTES SG21 GENERAL NOTES SS10 FLAT ROOF CONNECTION DETAILS SE10 ELECTRICAL DETAILS SE11 ELECTRICAL DETAILS NEC 2008 SE20 METERING AND SURGE PROTECTION DETAILS 3-PHASE SR10 THREE PHASE SYSTEM CUTSHEETS SR25 ELECTRICAL DATA CUTSHEETS SR26 ELECTRICAL DATA CUTSHEETS SR30 STRUCTURAL COMPONENT CUTSHEETS 01 AERIAL PHOTO NOT TO SCALE 02 VICINITY MAP NOT TO SCALE INDIANA CLB CAMERON L. BRYANT 10505919 CLB 25/JUN/20 NOTE 1 : INTERNATIONAL BUILDING CODE 2018 REFERENCES THE MOST CURRENT DESIGN PRACTICES RELATED TO STRUCTURAL ANALYSIS AND DESIGN OF ROOFTOP SOLAR MODULE SYSTEMS. ANALYSIS AND DESIGN OF ROOFTOP SOLAR MODULE SYSTEMS WAS PERFORMED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE 2018 AND MEETS 2014 INDIANA BUILDING CODE REQUIREMENTS. NOTE 2 : INTERNATIONAL FIRE CODE 2018 REFERENCES THE MOST CURRENT DESIGN PRACTICES RELATED TO DESIGN OF ROOFTOP SOLAR MODULE SYSTEMS. ANALYSIS AND DESIGN OF ROOFTOP SOLAR MODULE SYSTEMS WAS PERFORMED IN ACCORDANCE WITH INTERNATIONAL FIRE CODE 2018 AND MEETS 2014 INDIANA FIRE CODE REQUIREMENTS. KPI AT NRS CLB CLB 04/20/21 CHECKED DATE DRAWN CODE APPPDE CHK DES NO DATE REVISIONS AND RECORD OF ISSUE DRAWING NUMBERPROJECT REV AREADRN ANSI D 34x22R J.P. MORGAN CHASE TRANCHE 6 - INDIANA COVER PAGE J.P. MORGAN CHASE ROOFTOP SOLAR PROGRAM TRANCHE 6 - INDIANA IN-STNDRD-SG10 STANDARD DRAWING PACKAGE 0 04/JUN/20 ISSUED FOR PERMITTING AWC AWC 02/14/2017 04:16 PM DESIGNER AWCAWC 1 JDL JDL 04/JUN/20 JDL JJA 1 04/FEB/21 APPROVED FOR CONSTRUCTION AWC AWC JDL JDLJJA 4-FEB-2021 04/20/21