HomeMy WebLinkAboutOne Line Diagram(N) ( KVA) 480/277V - 208V TRANSFORMER TR1 45 INV1 (N) INVERTER 04 (N) AC SURGE PROTECTORSP1 LEGEND (N) - NEW EQUIPMENT (E) - EXISTING EQUIPMENT 02 01 PHOTOVOLTAIC STRINGS PM OPT 20 12 9 # REFER TO E30 FOR PLACARD LABELING 7 (N) GENERATOR DISCONNECT SWITCH SW1 F1 RGM (N) OWNER REVENUE GRADE METER 05 7 8 6 117 11 5 (N) INVERTER FUSED DISCONNECT SWITCH SW2 F2 03 21 6 2 (E) MAIN TO UTILITY GRID (E) BI-DIRECTIONAL UTILITY METER 15 4 3 13 (E) LOADS (10 FEET OR LESS) (E) ELECTRICAL SERVICE PANEL 208/120V, 3 PHASE, 4 WIRE MAIN BUS: 225A MAIN BREAKER: 225A NOTES: 1. THIS CABLE SIZE AND INSTALLATION ALSO APPLIES TO THE CABLE INTERCONNECTING MODULES IN THE SAME STRING WHERE IT IS NOT PROTECTED UNDERNEATH THE PV ARRAY. THE CONDUIT SIZE IS CALCULATED BASED ON THE MAXIMUM SET OF STRINGS ROUTED TO A SINGLE INVERTER. 2. AC SURGE PROTECTOR (SP1) AND OWNER REVENUE GRADE METER (RGM) SHOWN ON THE THREE LINE DIAGRAM ARE INSTALLED IN PNL2. REFER TO SE20 FOR TYPICAL WIRING DIAGRAM DETAILS. 3. SUBCONTRACTOR SHALL REPLACE EXISTING LOAD SIDE METER LUGS WITH A DUAL LUGGED CONNECTOR TO ACCEPT WIRING. IF CORRECT CONNECTORS ARE NOT AVAILABLE, SUBCONTRACTOR SHALL REPLACE METER SOCKET OR PURCHASE AND INSTALL LOCKABLE NEMA 3R WIREWAY BELOW METER BASE AND INTERCONNECT USING POLARIS CONNECTORS OR ENGINEER APPROVED EQUIVALENT. PLEASE REFER TO DUKE ENERGY GOLD BOOK FIG 142A. 4. REFER TO ELECTRICAL DETAILS DRAWING SE10 FOR THE COMMUNICATION DETAIL. 5. NEW PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH TO BE LOCATED CLOSE TO EXISTING METER PER UTILITY REQUIREMENTS. 6. SUBCONTRACTOR SHALL USE LOCK PROVIDED BY DISTRIBUTOR TO LOCK THE METERING AND SURGE PROTECTION CABINET, INVERTER DISCONNECT SWITCH AND GENERATOR DISCONNECT SWITCH. NOTE 3 23 23 22 CHECKED DATE DRAWN CODE APPPDE CHK DES NO DATE REVISIONS AND RECORD OF ISSUE DRAWING NUMBERPROJECT REV AREADRN ANSI D 34x220 25/JUN/20 ISSUED FOR PERMITTING 1 11/FEB/21 ISSUED FOR PERMITTING 02/14/2017 04:16 PM 25/JUN/20 DESIGNER 1R IN-156701-E21 J.P. MORGAN CHASE 13085 PETTIGRU DRIVE, CARMEL, IN 46032-4436 ONE LINE DIAGRAMNRS NRS APN APN NRS NRS MODULE MAKE MISSION SOLAR MODEL MSE375SQ9S POWER OUTPUT 375 W SHORT CIRCUIT Isc 9.83 A OPEN CIRCUIT VOLTAGE Voc 48.16 V RATED CURRENT Imp 9.43 A RATED VOLTAGE Vmp 39.76 V TEMPERATURE COEFFICIENT OF Voc -0.28%/C TEMPERATURE COEFFICIENT OF Isc 0.046%/C OPTIMIZER MAKE SOLAR EDGE MODEL P850 RATED INPUT DC POWER 850 W MAXIMUM SYSTEM VOLTAGE 1000 V MAXIMUM OUTPUT CURRENT 18.0 A MAXIMUM OUTPUT VOLTAGE 85 V MAXIMUM INPUT VOLTAGE 120 V MAXIMUM SHORT CIRCUIT CURRENT 12.5 A MINIMUM MODULES IN SERIES 27 MAXIMUM MODULES IN SERIES 40 SYSTEM INFORMATION DC WIRING LOSSES AT STC STRING INPUTS MODULES IN SERIES DC POWER (STC) TOTAL DC POWER (STC) INVERTER AC POWER ILR INVERTER OUTPUT CURRENT ESTIMATED CIRCUIT LENGTH % VOLTAGE DROP % STC LOSS INVERTER-1 STRING 1-1 30 11,250 W 33,750 W 33,300 W 1.01 40.0A 265 0.66% 0.66% STRING 1-2 30 11,250 W 230 0.57% 0.57% STRING 1-3 30 11,250 W 340 0.84% 0.84% WEIGHTED AVERAGE 0.69% 0.69% DESIGN PARAMETERS ASHRAE EXTREME LOW -23.8 °C ASHRAE 2% HIGH 32.4 °C SERVICE VOLTAGE 208V, 3Ф UTILITY DUKE ENERGY ELECTRICAL CODE NEC 2008 DISTRIBUTOR BILL OF MATERIAL REF CATEGORY MAKE MODEL QTY UNIT DESCRIPTION PM MODULE MISSION SOLAR MSE375SQ9S 90 EA 375WP, 72 CELL SOLAR MODULE (PROVIDED BY JPMC) OPT DC OPTIMIZER SOLAREDGE P850 45 EA SOLAREDGE POWER OPTIMIZER INV1 33.3KW INVERTER SOLAREDGE SE33.3KUS 1 EA UTILITY INTERACTIVE DC-TO-AC INVERTER: 3-PHASE, 4-WIRE, 480/277VAC, NEMA 3R, NEC 2014 and 2017 RAPID SHUTDOWN COMPLIANT CELL1 CELLULAR CDMA KIT SOLAREDGE SE-CELL-B-R05-S-S4 1 EA CDMA MODEM W/SIM, INV≤33.3KVA, 5YRS, HB 15MIN PNL2 METERING AND SURGE PROTECTION CABINET VARIES DETAIL 01 1 EA REFER TO DRAWING SE20 FOR CABINET DESIGN AND BOM TR1 TRANSFORMER HPS 226427 1 EA TRANSFORMER 45kVA, 480/277 WYE-GND/208VAC DELTA, NEMA 3R SW1 UTILITY DISCONNECT EATON DG324NRK 1 EA 240VAC, 200A, 3 POLE GENERAL-DUTY,FUSIBLE, SINGLE-THROW DISCONNECT SWITCH, NEMA 3R F1 UTILITY DISCONNECT FUSE BUSSMANN FRN-R-125 3 EA FUSE, 125A, 250VAC, SCCR 200 kA SW2 INVERTER DISCONNECT EATON DH362NRK 1 EA 600VAC 60A, 3 POLE, HEAVY-DUTY, FUSIBLE, SINGLE-THROW DISCONNECT SWITCH, NEMA 3R F2 INVERTER DISCONNECT FUSE BUSSMANN FRS-R-50 3 EA FUSE, 50A, 600VAC, SCCR 200 kA INVERTER MAKE SOLAREDGE MODEL SE33.3KUS MAXIMUM AC POWER OUTPUT 33,300 W AC RATED VOLTAGE 480Y/277 V MAX CONTINUOUS OUTPUT CURRENT 40.0 A RATED INPUT VOLTAGE 840 V MAXIMUM INPUT CURRENT 40.0 A MAXIMUM SHORT CIRCUIT CURRENT 45.0 A MAXIMUM INPUT VOLTAGE 980 V TRANSFORMER-LESS, UNGROUNDED YES SYSTEM SUMMARY TOTAL DC POWER 33,750 W TOTAL AC POWER 33,300 W WEIGHTED ILR 1.01 INVERTER OUTPUT RATED VOLTAGE 480 V MAX AC CURRENT (480 V) 40.0A TRANSFORMATION VOLTAGE 208 V MAX AC CURRENT (208 V) 92.3A 01 ONE LINE DIAGRAM NOT TO SCALE JDL JASON D. LEIMBACK 11100106 INDIANA JDL 25/JUN/20 NRS APN NRS JDL JDL CONDITIONS OF USE CONDUCTOR EGC CONDUIT CIRCUIT INFORMATION CIRCUIT ID DESCRIPTION NUMBER OF TYPICAL CIRCUITS INSULATION TEMP. RATING RACEWAY LOCATION MODIFIED AMBIENT TEMPERATURE # CURRENT CARRYING CONDUCTORS CONDUIT FILL DERATE FACTOR TEMPERATURE DERATE FACTOR MINIMUM SPECIFICATION MINIMUM SPECIFICATION MIN SIZE # OF CONDUCTORS # OF EGC CONDUIT FILL % CONDUCTOR AMPACITY CONDUCTOR DERATED AMPACITY CONT. CURRENT MAXIMUM CURRENT OCPD ESTIMATED CIRCUIT LENGTH % VOLTAGE DROP % AVERAGE LOSSES 01 STRING TO INVERTER (NOTE 1) 3 90 °C > 3.5" & < 12" 49 °C 2 0.8 0.82 8 AWG, COPPER, PV WIRE 10 AWG, COPPER, RHW-2 1.25", EMT 6 1 33% 55 A 36 A 18.0A 22.5A 25 278 FT 0.69% 0.69% 02 33.3KW INVERTER TO INVERTER DS 1 90 °C UNDER ROOF 32 °C 3 1 0.96 8 AWG, COPPER, THWN-2 10 AWG, COPPER, THWN-2 0.75", EMT 4 1 31% 55 A 53 A 40.0A 50.0A 50 10 FT 0.11% 0.11% 03 INVERTER DS TO TRANSFORMER 1 90 °C UNDER ROOF 32 °C 3 1 0.96 8 AWG, COPPER, THWN-2 8 AWG, COPPER, THWN-2 0.75", EMT 4 1 34% 55 A 53 A 40.0A 50.0A 50 10 FT 0.11% 0.11% 04 TRANSFORMER TO UTILITY DS 1 90 °C UNDER ROOF 32 °C 3 1 0.96 1 AWG, COPPER, THWN-2 6 AWG, COPPER, THWN-2 1.5", EMT 3 1 26% 145 A 139 A 92.3A 115.4A 125 20 FT 0.25% 0.25% 05 UTILITY DS TO POI 1 90 °C UNDER ROOF 32 °C 3 1 0.96 1 AWG, COPPER, THWN-2 NA 1.5", RMC 4 0 30% 145 A 139 A 92.3A 115.4A 125 10 FT 0.12% 0.12% TOTAL 1.36% 1.36% 04/20/21