HomeMy WebLinkAboutPlacardsCHECKED DATE DRAWN CODE APPPDE CHK DES NO DATE REVISIONS AND RECORD OF ISSUE DRAWING NUMBERPROJECT REV AREADRN ANSI D 34x220 25/JUN/20 ISSUED FOR PERMITTING 1 11/FEB/21 ISSUED FOR PERMITTING 02/14/2017 04:16 PM 25/JUN/20 DESIGNER 1R J.P. MORGAN CHASE 13085 PETTIGRU DRIVE, CARMEL, IN 46032-4436 PLACARDS SERVICE DISCONNECTING MEANS PV ARRAY !CAUTION! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: IN-156701-E30 GENERATOR DISCONNECT SWITCH OPERATING DC CURRENT: 54 A OPERATING DC VOLTAGE: 840 V MAX SHORT CURRENT: 45 A MAX VOLTAGE: 980 V AT EACH 33.3 KW INVERTER DC DISCONNECTING MEANS [NEC 690.53] 20 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE GENERATOR DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PV SYSTEM DISCONNECTING MEANS [NEC 690.4(D)] PHOTOVOLTAIC AC DISCONNECT AT POINT OF INTERCONNECTION, MARKED AT DISCONNECTING MEANS [NEC 690.54] OPERATING AC CURRENT: 92.3A OPERATING AC VOLTAGE: 208V, 3Ф ! WARNING ! ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. AT EACH JUNCTION, COMBINER, DISCONNECT AND DEVICE WHERE ENERGIZED UNGROUNDED CONDUCTORS MAY BE EXPOSED DURING SERVICE [NEC 690.35(F)] ! WARNING ! ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. ! WARNING ! DUAL POWER SOURCES. SECOND SOURCE IS PV SYSTEM PHOTOVOLTAIC DC DISCONNECT GENERATOR DISCONNECT SWITCH WARNING: PHOTOVOLTAIC POWER SOURCE ! CAUTION ! PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED ! WARNING ! INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE PHOTOVOLTAIC SYSTEM METER INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED AT UTILITY METER [NEC 690.56(B)] PLAQUE INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED SOUTH SIDE OF THE BUILDING ! WARNING ! ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT ! WARNING ! TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL AT EACH BREAKER PANEL AND MAIN SERVICE DISCONNECT. [NEC 110.27(C)] ! WARNING ! PHOTOVOLTAIC SYSTEM DATA ACQUISITION SYSTEM AUTHORIZED PERSONNEL ONLY THE PV DAS SHALL BE LABELED WITH THE FOLLOWING INFORMATION AT EACH AC DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL AND DISCONNECT. [NEC 110.16] ! WARNING ! ARC FLASH HAZARD. APPROPRIATE PPE REQUIRED. FAILURE TO COMPLY MAY RESULT IN INJURY OR DEATH. REFER TO NFPA 70 E. AT EACH PHOTOVOLTAIC SYSTEM SERVICE DISCONNECT SWITCH. ! DANGER ! ARC FLASH AND SHOCK HAZARD PRESENT DO NOT OPEN DOOR WHILE ENERGIZED INCIDENT ENERGY EXCEEDS MAX PPE PROTECTION PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PHOTOVOLTAIC SYSTEM SERVICE DISCONNECT SWITCH DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS TO THIS PANEL AT DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL (IF APPLICABLE) AT THE SERVICE ENTRANCE (ELECTRICAL SERVICE PANEL) AND GENERATOR DISCONNECT SWITCH NET GENERATION OUTPUT METER AT NET GENERATION OUTPUT METER AT THE ELECTRICAL SERVICE PANEL ! WARNING ! A GENERATION SOURCE IS CONNECTED TO THE SUPPLY (UTILITY) SIDE OF THE SERVICE DISCONNECTING MEANS. FOLLOW PROPER LOCKOUT/TAGOUT PROCEDURES TO ENSURE THE PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH IS OPENED PRIOR TO PERFORMING WORK ON THE DEVICE. 1 2 3 5 1716 15 14 13 12 9 10 11 6 7 8 419 18 AT EACH AC DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT [NEC 690.17] AT EACH DC DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT [NEC 690.17] AT PHOTOVOLTAIC SYSTEM SERVICE DISCONNECT SWITCH [NEC 690.14(C)(2)] AT GENERATOR DISCONNECT SWITCH [NEC 690.14(C)(2)] AT EACH DC DISCONNECTING MEANS [NEC 690.14(C)(2)] AT EACH DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER. [NEC 705.12(D)(7)] AT POINT OF INTERCONNECTION; LABEL MUST IDENTIFY PHOTOVOLTAIC SYSTEM [NEC 705.12(D)(4)] AT POINT OF INTERCONNECTION; LABEL MUST IDENTIFY PHOTOVOLTAIC SYSTEM [NEC 705.12(D)(4)] AT PHOTOVOLTAIC SYSTEM SERVICE DISCONNECT SWITCH [NEC 2014 - 690.56(C)]. LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND; REFLECTIVE [IFC 605.11.1.1]. AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(E)] LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND; REFLECTIVE [IFC 605.11.1.1] LABELING NOTES 1.1 LABELING REQUIREMENTS BASED ON THE 2008 NATIONAL ELECTRICAL CODE. 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT FOR WHICH THEY ARE INSTALLED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. NRS NRS APN APN NRS NRS JDL JASON D. LEIMBACK 11100106 INDIANA PHOTOVOLTAIC SYSTEM INVERTER DISCONNECT SWITCH 21 AT INVERTER DISCONNECT JDL 25/JUN/20 NRS APN NRS JDL JDL 23 22 04/20/21