HomeMy WebLinkAboutSite PlanCHECKED DATE
DRAWN CODE
APPPDE CHK DES NO DATE REVISIONS AND RECORD OF ISSUE
DRAWING NUMBERPROJECT REV
AREADRN ANSI D 34x220 25/JUN/20 ISSUED FOR PERMITTING
1 11/FEB/21 ISSUED FOR PERMITTING
02/14/2017 04:16 PM
25/JUN/20
DESIGNER
1R
IN-156701-G20
J.P. MORGAN CHASE
13085 PETTIGRU DRIVE, CARMEL, IN 46032-4436
SITE PLAN
LEGEND:
FLAT ROOF CLEARANCE AREA
PITCHED ROOF CLEARANCE AREA
(E) EXISTING
(E) PROPERTY LINE
NOTES:
1. CONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS AND ROOF SLOPES
AND COORDINATE WITH ALL REFERENCE DRAWINGS AS REQUIRED. IF THE
CONTRACTOR ENCOUNTERS CONDITIONS OTHER THAN WHAT IS SHOWN ON
THE DRAWINGS, CONTRACTOR SHALL NOTIFY THE ENGINEER
OF RECORD PRIOR TO START OF CONSTRUCTION.
2. SEE SHEET SG20 AND SG21 FOR GENERAL NOTES, LEGEND AND SYMBOLS.
4. OBSTRUCTIONS IN CLEARANCE AREA PATHWAYS SHALL BE KEPT TO A
MINIMUM.
5. SOLAR ASSEMBLY DOES NOT INCREASE EXISTING BUILDING HEIGHT FOR
PITCHED ROOFS. FOR FLAT ROOFS, SOLAR ASSEMBLY EXTENDS 11 3/8"
MAXIMUM ABOVE ROOF SURFACE WITH UNIRAC RMDT RACKING AND EXTENDS
1'-1 7/8" MAXIMUM ABOVE ROOF SURFACE WITH IRONRIDGE BX RACKING.
ROOF DESIGN CLEARANCE TABLE (SEE LEGEND FOR APPLICABLE HATCH)
ITEM MINIMUM CLEARANCE DIMENSIONS
FLAT ROOF 4'-0"
PITCHED ROOF:
ALONG RIDGE 6'-0" (3'-0" MINIMUM EACH SIDE)
PITCHED ROOF:
ALONG HIPS/VALLEY 3'-0" (18" MINIMUM EACH SIDE)
PITCHED ROOF:
ALONG EAVE/FREE EDGE 0'-10"
PITCHED ROOF:
OTHER CLEARANCE ON ROOF PLANE 3'-0"
ROOF CONNECTION DETAIL TABLE
DRAWING DETAIL ROOF SLOPE FRAMING TYPE ROOF TYPE CONNECTION LOCATION NOTES
SS10 1 FLAT ROOF DECK VARIES SEE SITE PLAN SEE RACKING SITE SPECIFIC DRAWING PACKAGE IF APPLICABLE.
SS10 2 FLAT ROOF DECK LOOSE GRAVEL
SS21 1 PITCHED WOOD MEMBERS ASPHALT SHINGLE SEE DRAWING SS20
SS21 2 PITCHED ROOF DECK SINGLE-PLY MEMBRANE SEE DRAWING SS20
SS21 3 PITCHED NA METAL STANDING SEAM SEE DRAWING SS20
SS21 4 PITCHED WOOD MEMBERS CORRUGATED METAL SEE DRAWING SS20
SS21 5 PITCHED STEEL MEMBERS ASPHALT SHINGLE SEE DRAWING SS20
SS22 1 PITCHED WOOD MEMBERS TILE SEE DRAWING SS20
SS22 2 PITCHED WOOD MEMBERS TILE SEE DRAWING SS20
SS22 3 PITCHED WOOD MEMBERS TILE SEE DRAWING SS20
SS22 4 PITCHED WOOD MEMBERS TILE SEE DRAWING SS20
SS22 5 PITCHED WOOD MEMBERS TILE SEE DRAWING SS20
NOTES:
1. ROOFS WITH SLOPE LESS THAN 7 DEGREES ARE CONSIDERED "FLAT". ROOFS WITH SLOPE GREATER THAN 7 DEGREES ARE CONSIDERED "PITCHED". REFER
TO SITE SPECIFIC DWG E10 FOR ROOF SLOPE.
2. FRAMING TYPE AND ROOF TYPE SHALL BE VERIFIED ON SITE PRIOR TO INSTALLATION.
3. EVEREST RACKING RAIL MAXIMUM ALLOWABLE SPAN
SHALL BE 4'-0" UNLESS NOTED OTHERWISE.
01 SITE PLAN
NOT TO SCALE
PARCEL DATA FROM LANDGRID.COM
KPI KPI AT
AT
NRS NRS
INDIANA
CLB
CAMERON L. BRYANT
10505919
CLB
25/JUN/20
ROOF MEMBRANE: BLACK RUBBER (EPDM)
ROOF DECK: METAL DECK
CONNECTION DETAIL: NONE. SEE DWG SS10 FOR BALLAST CRITERIA.
RACKING TYPE: UNIRAC RMDT
17'-8"
KPI ATNRS CLB CLB
THE PROVISIONS OF THE INTERNATIONAL FIRE CODE 2018, SEC. 1204.2.1
PERTAINING TO GROUP R-3 BUILDINGS (ONE OR TWO FAMILY DWELLINGS)
SPECIFIES SETBACKS AND PATHWAYS FOR PITCHED ROOFS. EXCEPTION TO
SEC. 1204.3 STATES THAT IF THE FIRE CODE OFFICIAL DETERMINES THAT THE
ROOF CONFIGURATION FOR A BUILDING OTHER THAN GROUP R-3 IS SIMILAR
TO THAT OF A GROUP R-3 OCCUPANCY, THE RESIDENTIAL ACCESS
REQUIREMENTS IN SEC. 1204.2.1 ARE A SUITABLE ALTERNATIVE. THEREFORE,
CONSIDERING FIREFIGHTING OPERATIONS, BUILDINGS WITH A PITCHED ROOF
HAVE BEEN CONSIDERED SIMILAR TO THAT OF A GROUP R-3 BUILDING AND
THE PROVISIONS OF SEC. 1204.2.1 WERE USED.
04/20/21