HomeMy WebLinkAboutD101 1ST FL DEMO PLANUP
UP
UP
1 2 3 4 5
D
E
C
B
A
2
2
3 2 3
3
OFFICE
108
OFFICE
107
LOBBY
102
VEST.
101
CONFERENCE
104
BREAK
110
OFFICE
113
IT
106
RECEPTION
103
OFFICE
114
OFFICE
115
RR
134
WOMEN'S RR
105
STAIR
ST-1
STOR.
112
OFFICE
111
MEN'S RR
109
1
1
1
1
1
1
1
1
STORAGE
125
WOMEN'S
RESTROOM
124
MEN'S
RESTROOM
123
STORAGE
122
BREAK
ROOM
121
VESTIBULE
120
5
4
6 7 8
1 1
1
1
1
1
1
8 11
12
10
13 2
1
1
NO WORK THIS
AREA UNDER
PHASE 1
A. VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY THE
ARCHITECT OF ANY CONFLICTS PRIOR TO PROCEEDING
B. ALL FURNITURE AND FURNISHINGS WILL BE REMOVED, RELOCATED AND/OR STORED BY
OWNER UNLESS NOTED OTHERWISE.
C. ALL ITEMS BEING REMOVED SHALL REMAIN THE PROPERTY OF THE OWNER UNTIL
CONFIRMATION HAS BEEN MADE AS TO WHETHER THE OWNER WILL RETAIN SUCH
ITEMS. CONTRACTOR SHALL COORDINATE WITH OWNER REGARDING DELIVERY OF ALL
ITEMS BEING RETAINED; ALL ITEMS NOT BEING RETAINED BY THE OWNER OR
DESIGNATED ON THE DRAWINGS TO BE SALVAGED, RELOCATED OR REINSTALLED
SHALL BE COMPLETELY REMOVED FROM THE SITE.
D. THE DEMOLITION CONTRACTOR SHALL PROVIDE AND INSTALL TEMPORARY DUST
PARTITIONS, CONSTRUCTION BARRIERS, TEMPORARY DOORS, WALK-OFF MATS AND
EQUIPMENT PROTECTION WHERE SHOWN ON THE DOCUMENTS OR IF NOT SHOWN, AS
REQUIRED BY THE WORK BEING PERFORMED. TEMPORARY DUST PARTITION SHALL BE
COMPLETELY SEALED TO PREVENT CONSTRUCTION DUST FROM ENTERING OWNER'S
ADJACENT SPACES. DUST PARTITION DOOR TO BE SELF CLOSING, POSITIVE LATCHING,
AND PAD-LOCKABLE. SUCH PROTECTION SHALL BE MAINTAINED AND REPAIRED
PROMPTLY IF DAMAGED TO AVOID DUST INFILTRATION INTO ADJACENT AREAS.
PROVIDE HEPA FILTER FILTRATION AND NEGATIVE AIR MACHINES WITH MONITORING
GAGES.
E. COVER ALL RETURN AIR GRILLES AND EXHAUST GRILLES IN CONSTRUCTION AREA WITH
MIN. MERV 13 FILTER MEDIA, CHANGED REGULARLY.
F. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DOCUMENTS FOR RESPECTIVE
DEMOLITION INFORMATION.
G. FILL ALL FLOOR CONSTRUCTION WHERE PIPING, CONDUITS, AND OTHER
PENETRATIONS HAVE BEEN REMOVED.
H. DEMOLITION WORK SHALL BE PERFORMED DURING NORMAL WORKING HOURS UNLESS
NOISE WILL EXCEED OSHA THRESHOLDS. IF NOISE IS ANTICIPATED TO EXCEED OSHA
THRESHOLDS, CONTRACTOR SHALL COORDINATE WITH OWNER TO ADJUST WORK
HOURS TO MORE APPROPRIATE TIMES. CONTRACTOR SHALL USE ALL METHODS TO
DECREASE NOISE IMPACT.
I. ASBESTOS CONTAINING MATERIAL IS NOT ANTICIPATED IN THE AREA OF DEMOLTION. IF
ACM's ARE SUSPECTED OR ENCOUNTED, CONTRACTOR SHALL NOTIFY THE ARCHITECT
IMMEDIATELY.
J. REMOVE ALL WALL COVERING, OTHER WALL TREATMENT, AND ATTACHMENTS. PATCH,
SKIM COAT, AND PREPARE FOR FINAL FINISH ON WALLS NOT BEING COVERED BY NEW
CONSTRUCTION.
K. IF USING A DEMOLITION CHUTE, IT SHALL BE FULLY ENCLOSED.
Project Number
CERTIFIED BY
ISSUANCE INDEX
DATE:
PROJECT PHASE:
4/7/2021 1:37:08 PM
D101
FIRST FLOOR
DEMOLITION PLAN
2021.00173
04/05/2021
CONSTRUCTION DOCUMENTS
ARTISTIC COMPOSITE
PALLETS - PHASE 1
4518 WEST 99TH
STREET CARMEL, IN
46032
N
3/32" = 1'-0"
D101
1 FIRST FLOOR DEMOLITION PLAN
1 REMOVE EXISTING WALL BASE.
2 REMOVE EXISTING WALL CONSTRUCTION COMPLETE, INCLUDING BUT
NOT LIMITED TO; ELECTRICAL OUTLETS, SWITCHES, VINYL BASE, ETC.
PATCH CONCRETE FLOOR AS REQUIRED TO RECEIVE NEW FLOORING
FINISH.
3 REMOVE EXISTING DOOR AND FRAME. SALVAGE FOR REINSTALLATION
IN NEW LOCATION.
4 REMOVE TILE FLOORING TO EXTENTS SHOWN.
5 REMOVE EXISTING PLUMBING FIXTURES. SALVAGE FOR
REINSTALLATION IN NEW LOCATION.
6 REMOVE EXISTING WALL MOUNTED TOILET ACCESSORIES. SALVAGE
FOR REINSTALLATION IN NEW LOCATION.
7 REMOVE EXISTING FLOOR AND WALL TILE. PREPARE SLAB FOR NEW
FINISHES PER MANUFACTURERS RECOMMENDATIONS.
8 REMOVE EXISTING CEILING SYSTEM TO EXTENTS SHOWN.
9 REMOVE EXISTING CARPET TILE. SALVAGE FOR REINSTALLATION IN
NEW LOCATION. PREPARE SLAB FOR NEW FINISHES PER
MANUFACTURERS RECOMMENDATIONS.
10 REMOVE EXISTING WINDOW SYSTEM.
11 REMOVE EXISTING LIGHT FIXTURE AND SUPPLY GRILLE. SALVAGE FOR
REINSTALLATION IN NEW LOCATION.
12 REMOVE EXISTING LIGHT FIXTURE AND EXHAUST FAN. SALVAGE FOR
REINSTALLATION IN NEW LOCATION.
13 REMOVE EXISTING FIRE EXTINGUISHER CABINET. SALVAGE FOR
REINSTALLATION IN NEW LOCATION.
14 REMOVE EXISTING COUNTERTOP ONLY.
KEYED DEMO PLAN NOTES (NOTED WITH 1 )
GENERAL DEMOLITION NOTES
REVISION SCHEDULE
NO. DESCRIPTION DATE
04/26/21