HomeMy WebLinkAboutG001 SHEET INDEXEARTH
NOTE:PATTERNS SHOWN REPRESENT CUT
MATERIALS IN PLAN OR SECTION, UNLESS NOTED
GRANULAR FILL OTHERWISE.
CONCRETE, CAST-IN-PLACE
CONCRETE, PRECAST/CAST
STONE
CONCRETE MASONRY UNIT
BRICK MASONRY
STONE: LIMESTONE, GRANITE,
MARBLE OR AS NOTED
METAL: TYPE AS NOTED
METAL: ROLLED SHAPES
WOOD FRAMING / BLOCKING:
CONTINOUS
WOOD SHIM
WOOD/FINISHED,
SHOWN CUT AND ELEVATION
PLYWOOD
PARTICLEBOARD
EIFS
SPRAYED FIREPROOFING
SHOWN ON ROLLED SHAPE
BATT INSULATION: THERMAL OR
ACOUSTICAL, UNO
RIGID INSULATION: THERMAL,
ACOUSTICAL, OR SAFING
SHEATHING: GYPSUM, OR AS
NOTED
GYPSUM WALL BOARD
TILE: CERAMIC, QUARRY, UNO
RESINOUS FLOORING: TERRAZO,
TROWEL-ON, UNO
ACOUSTICAL CEILING TILE
GRATING (PLAN)
INSULATED GLASS:
(SMALL SCALE)
GRATING (SECTION)
MEMBRANE: WATERPROOF,
ROOF, DAMPPROOFING
AIR BARRIER SYSTEM
INSULATED GLASS:
(DETAIL)
TERRA COTTA, STRUCTURAL CLAY
TILE
CARPET, CARPET TILE (DETAIL)
SAND, GROUT
AS NOTED
GLASS FIBER REINFORCED
CONCRETE SIDING OR TRIM
WOOD/ENGINEERED: GLUE
LAMINATED
PLASTER ON METAL LATH
WOOD FLOOR, WOOD SHINGLES,
OR SIDING
ENLARGED DRAWING REFERENCE
ELEVATION DATUM REFERENCE
NORTH ARROW
DRAWING NUMBER
SHEET NUMBER
BUILDING SECTION CUT REFERENCE
SF27
101
A101
1
SIM
1
1
W3
N
1
KEYED NOTE
REVISION REFERENCE
STOREFRONT/CURTAINWALL/WINDOW TAG
DOOR TAG
ROOM NAME AND NUMBER
COLUMN GRID NEW
A
DRAWING NUMBER
SHEET NUMBER
WALL SECTION CUT REFERENCE
DRAWING NUMBER
SHEET NUMBER
EXTERIOR ELEVATION REFERENCE
WALL TYPE REFERENCE (REFERENCE
INTERIOR PARTITION LEGEND)
COLUMN GRID EXISTING
1 EQUIPMENT TAG
X
XX
X
XX
1 Ref
XX
Room
101
A. SEE SHEET G001 FOR GRAPHIC SYMBOL LEGEND.
B. SEE SHEET A000 FOR GENERAL PARTITION NOTES.
C. SEE SHEET A701 FOR GENERAL FINISH NOTES
D. COORDINATE WORK OF ALL TRADES PRIOR TO STARTING CONSTRUCTION.
E. ALL DIMENSIONS ARE TO GRID LINES, FACE OF STUD FRAMING, FINISHED FACE OF
EXISTING WALL SURFACE, OR FACE OF CONCRETE / MASONRY UNITS UNLESS NOTED
OTHERWISE.
F. THE CONTRACTOR AND SUBCONTRACTORS INVOLVED IN THIS PROJECT SHALL BE
RESPONSIBLE FOR DESIGNING AND INSTALLING THEIR RESPECTIVE WORK AND
SYSTEMS TO MEET ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES, LAWS,
SAFETY REGULATIONS, HAZARDOUS WASTE LAWS, ETC. THE CONTRACTOR SHALL
FURNISH ALL NECESSARY PERMITS.
G. THE CONTRACTOR SHALL REVIEW THE DRAWINGS AND UNDERSTAND THE SCOPE OF
THE DRAWINGS TO BE THE FOLLOWING: THESE CONSTRUCTION DOCUMENTS
(DRAWINGS, SPECIFICATIONS, ADDENDA, ETC.) INDICATE THE GENERAL SCOPE OF THE
PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPTS, THE DIMENSIONS OF THE
BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS, AND THE MAJOR STRUCTURAL,
MECHANICAL, AND ELECTRICAL SYSTEMS. THE DOCUMENTS DO NOT AND ARE NOT
INTENDED TO INDICATE OR DESCRIBE IN DETAIL ALL THE NECESSARY WORK REQUIRED
FOR FULL PERFORMANCE OF, AND COMPLETION OF THE REQUIREMENTS OF THE
CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED IN THESE DOCUMENTS,
THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER
EXECUTION AND COMPLETION OF THEIR WORK. CONTRACTORS SHALL FOLLOW AND
OBEY ALL FEDERAL, STATE AND LOCAL CODES, LAWS, SAFETY REGULATIONS AND
HAZARDOUS WASTE LAWS, ETC.
H. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN EACH BUILDING COMPONENT
LOCATION. BRING ANY DISCREPANCIES TO THE ARCHITECT'S ATTENTION IN WRITING
IMMEDIATELY.
I. BUILDING FIRST FLOOR IS REFERENCE ELEVATION 100'-0". REFERENCE CIVIL DRAWINGS
FOR U.S.G.S. ELEVATION.
J. ALL WORK SHALL BE PERFORMED IN A SKILLED WORKMANSHIP TYPE AND MANNER
ACCEPTABLE TO THE ARCHITECT AND OWNER.
K. CAULK INTERSECTION BETWEEN DIFFERENT MATERIALS.
L. CAULK TOILET FIXTURES AND COUNTERTOP SPLASHES TO FINISH SURFACE IN
ACCORDANCE WITH SEALANT SCHEDULE IN SPECIFICATIONS.
M. EXISTING CONDITIONS SHALL BE FIELD VERIFIED PRIOR TO BIDDING OR BEGINNING OF
WORK. ANY ERRORS OR OMISSIONS SHALL BE BROUGHT TO THE ARCHITECT'S
ATTENTION IN WRITING IMMEDIATELY.
N. COVER ALL RETURN AIR AND EXHAUST GRILLES WITH FILTER MEDIA FOR DURATION OF
JOB AND CHANGE REGULARLY.
O. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPE INDICATED ON THE
CONSTRUCTION DOCUMENTS IS INTENDED TO DEPICT GENERAL DESIGN INTENT ONLY.
ACTUAL WORK IS TO BE DESIGNED, PERMITTED AND EXECUTED BY A QUALIFIED
DESIGN-BUILD CONTRACTOR UNDER THE SUPERVISION OF THE GENERAL
CONTRACTOR. THE RESPONSIBLE CONTRACTOR SHALL FOLLOW AND OBEY ALL
FEDERAL, STATE AND LOCAL CODES, LAWS, SAFETY REGULATIONS AND HAZARDOUS
WASTE LAWS, ETC.
1. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE LIMITED TO
BASIC DESIGN-BUILD ALTERATIONS WHICH ARE OUTLINED IN THESE PLANS. THE DESIGN-
BUILD CONTRACTORS FOR EACH TRADE MUST NOTIFY THE ARCHITECT IF THEY FIND
THAT THE SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL OR
PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY NECESSARY
ENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF ADDITIONAL
INFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE MECHANICAL,
ELECTRICAL AND PLUMBING DESIGN-BUILD CONTRACTORS SHALL COMPLY WITH ALL
APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM
SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE DESIGN-BUILD CONTRACTOR AND
MUST COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE
SUPPRESSION AND FIRE ALARM DESIGN-BUILD CONTRACTORS ARE RESPONSIBLE FOR
COMPLETING AND FILING THEIR PLANS AND OBTAINING THEIR PERMITS.
2. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE
DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING
PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX
DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING
ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
3. VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE, AND
PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER PRIOR TO ANY
PURCHASE OF NEW EQUIPMENT. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY
SINGLE OFFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING
OWNER/LANDLORD.
4. RELOCATE AIR-SUPPLY DIFFUSERS AND RETURN-AIR GRILLES AS REQUIRED. PROVIDE
PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES.
CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS
REQUIRED BY CODE.
5. POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL
DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OR
OTHER CONFLICTS.
6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE
DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF
ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF
THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL
PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES.
7. COMPLY WITH THE INDIANA ELECTRICAL AND MECHANICAL CODE AND ALL OTHER
APPLICABLE CODES.
8. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. PROVIDE OR REUSE ELECTRICAL
POWER AND DATA OUTLETS AS REQUIRED.
9. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE G.F.C.I.
10. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO
BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND
PROVIDING APPROPRIATE TERMINALS AT FACE PLATE.
11. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCHPLATES TO
MATCH EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO
PURCHASE.
12. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE
SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING ELECTRICAL
CONDUITS TO JUNCTION BOXES.
13. IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL
LIGHTS IN EXISTING SPACES. CONSULT WITH LANDLORD.
14. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE
NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES.
15. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A.
REQUIREMENTS.
16. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE
COVER PLATE.
17. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWN LIGHTS,
SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS UNLESS OTHERWISE NOTED.
18. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC.
EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER
SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES
SHOWN ON PLAN ARE FOR REFERENCE ONLY.
19. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY
SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM &
DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL
BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE
ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH
DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO
DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
20. COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DETECTION
DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE WALLS
(CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANT-INSTALLED ITEMS (I.E.
PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS).
Project Number
CERTIFIED BY
ISSUANCE INDEX
DATE:
PROJECT PHASE:
4/7/2021 1:37:13 PM
G001
SHEET INDEX
2021.00173
04/05/2021
CONSTRUCTION DOCUMENTS
ARTISTIC COMPOSITE
PALLETS -PHASE 1
4518 WEST 99TH
STREET CARMEL, IN
46032
ORIG ORIGINAL
P
PERM PERMANENT
PH PHASE
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTIC
PNL PANEL
PREFAB PREFABRICATED
PREFIN PREFINISHED
PRELIM PRELIMINARY
PREP PREPARATION
PROJ PROJECT
PT PRESERVATIVE
TREATED
PTD PAINTED
PTN PARTITION
Q
QT QUARRY TILE
R
R RADIUS
RD ROOF DRAIN
REC RECESSED
RECPT RECEPTACLE
REF REFER(ENCE)
REINF REINFORCE(D)(ING)(M
ENT)
REQD REQUIRED
RESIL RESILIENT
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNOT
S
SAN SANITARY
SCW SOLID CORE WOOD
SF SQUARE FOOT
SPKLR SPRINKLER
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR or ST STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SYM SYMBOL
SYS SYSTEM
T
T&G TONGUE AND
GROOVE
T/ TOP OF
TEL TELEPHONE
TEMP TEMPORARY
THRES THRESHOLD
TOT TOTAL
TYP TYPICAL
U
UNIF UNIFORM
UNO UNLESS NOTED
OTHERWISE
UR URINAL
V
VB VINYL BASE
VCT VINYL COMPOSITION
TILE
VERT VERTICAL
VIN VINYL
VT VINYL TILE
VWC VINYL WALL
COVERING
W
W/W WALL TO WALL
WC WATER CLOSET
WD WOOD
WDW WINDOW
WH WALL HUNG
WT WEIGHT
G
GALV GALVANIZED
GLZ GLAZING
GUT GUTTER
GYP BD/GWB GYPSUM BOARD
H
HC HANDICAP(PED)
HCW HOLLOW CORE WOOD
HDWE/HDW HARDWARE
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING,
VENTILATION, AIR
CONDITIONING
I
ICF INSULATED
CONCRETE FORM
ID INSIDE DIAMETER
IF INSIDE FACE
INCAND INCANDESCENT
INDIC INDICATE
INSTL INSTALL(ATION)
INSUL INSULATION
INT INTERIOR
J
JST JOIST
JT JOINT
L
LAV LAVATORY
LD BRG LOAD BEARING
LF LINEAR FOOT
LTG LIGHTING
LTWT LIGHTWEIGHT
LVR LOUVER
M
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MED MEDICINE (MEDICAL)
MET METAL
MFG MANUFACTURER (ING)
MIN MINIMUM
MISC MISCELLANEOUS
MLWK MILLWORK
MO MASONRY OPENING
MTD MOUNTED
MTG MOUNTING
MULL MULLION
MULT MULTIPLE
N
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
O
O/O OUT TO OUT
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OFCI OWNER FURNISHED -
CONTRACTOR
INSTALLED
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPT OPTIONAL
ORD OVERFLOW ROOF
DRAIN
A
A/E ARCHITECT/ENGINEER
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING
TILE
ADA AMERICAN'S WITH
DISABILITIES ACT
ADD ADDENDUM
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
ARCH ARCHITECT (URAL)
B
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BRG BEARING
C
C/C CENTER TO CENTER
CAB CABINET
CB CORNER BEAD
CER CERAMIC
CF CUBIC FOOT
CFCI CONTRACTOR
FURNISHED /
CONTRACTOR
INSTALLED
CHAN CHANNEL
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CMU CONCRETE MASONRY
UNIT
CONC CONCRETE
CONSTR CONSTRUCTION
CONT CONTINUOUS
CP/CPT CARPET
D
DEMO DEMOLITION (ISH)
DF DRINKING FOUNTAIN
DIFF DIFFUSER
DIM DIMENSION
DISP DISPENSER
DO DOOR OPENING
DS DOWNSPOUT
DWG DRAWING
E
EJ EXPANSION JOINT
ELEC ELECTRICAL
(ELEVATOR)
ELEV ELEVATION
ENCL ENCLOSURE
ENGR ENGINEER
EQUIP EQUIPMENT
EWC ELECTRICAL WATER
COOLER
EXST EXISTING
F
F/F FACE TO FACE
FDN FOUNDATION
FE FIRE EXTINGUISHER
FHC FIRE HOSE CABINET
FIN FINISH
FIN FL FINISHED FLOOR
FLR (FLRG) FLOOR(ING)
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FR FIRE RATING
FT FIRE TREATED
FTG FOOTING
FURN FURNITURE
FURR FURRING
ABBREVIATIONS SHEET INDEX
SHEET NUMBER SHEET NAME
GENERAL
G000 COVER SHEET
G001 SHEET INDEX
G101 FIRST FLOOR LIFE SAFETY PLAN
G102 SECOND FLOOR LIFE SAFETY PLAN
ARCHITECTURAL DEMOLITION
D101 FIRST FLOOR DEMOLITION PLAN
D102 SECOND FLOOR DEMOLITION PLAN
ARCHITECTURAL
A000 WALL TYPES
A101 FIRST FLOOR PLAN
A102 SECOND FLOOR PLAN
A121 FIRST FLOOR REFLECTED CEILING PLAN
A122 SECOND FLOOR REFLECTED CEILING PLAN
A401 ENLARGED PLANS AND ELEVATIONS
A601 DOOR SCHEDULES
A701 FIRST FLOOR FINISH PLAN
A702 SECOND FLOOR FINISH PLAN
A721 ROOM FINISH SCHEDULE AND FINISH DETAILS
E101 FIRST FLOOR ELECTRICAL PLAN
E102 SECOND FLOOR ELECTRICAL PLAN
MATERIALS LEGEND GRAPHIC LEGEND
GENERAL NOTES
MECHANICAL AND ELECTRICAL NOTES
REVISION SCHEDULE
NO. DESCRIPTION DATE
04/26/21