HomeMy WebLinkAboutG102 2ND FL LIFE SAFETY PLAN1 2 3 4 5 6 7 8 D E C B A CONFERENCE 204 OFFICE 205 OFFICE 203 OFFICE 202 OFFICE 201 OFFICE 207 OPEN OFFICE 206 OFFICE 212 MECH 211 OFFICE 208 RR 210 RR 209 STAIR ST-2 FE 78' -2" EXISTING SPACE N.I.C. APPLICABLE BUILDING CODES 2014 Indiana Building Code, (2012 International Building Code & Local Amendments) 2014 Indiana Fire Code, (2012 International Fire Code & Local Amendments) 2009 Indiana Electrical Code, ()2008 National Electrical Code & Local Amendments) 2014 Indiana Mechanical Code (2012 International Mechanical Code & Local Amendments) 2012 Indiana Plumbing Code, (2006 International Plumbing Code & Local Amendments) OCCUPANCY CLASSIFICATION Business, F-1, S-1 CONSTRUCTION TYPE Type IIB SPRINKLER SYSTEM Equipped throughout with an automatic sprinkler system in accordance with 903.3.1.1 -exsiting system to remain. LIFE SAFETY / BUILDING CODE SUMMARY TRAVEL DISTANCE RESTRICTIONS • Dead-end Corridor Limit:50 ft (1018.4, ex. 2) • Common Path of Travel:100 ft (Table 1014.03) • Exit Travel Distance: F-1 & S-1 250 ft to exit access or exit (Table 1016.2) B 300 ft to exit access or exit MISCELLANEOUS REQUIREMENTS • Two accessible exits required from 2nd floor (1007.1; 1015.1) • Both Stairs can be unenclosed (1009.3, exptn. 1) • No area of refuge required (1007.3, exptn. 2) • Required stair width = 44" (1007.3, exptn. 1; 1009.4) BUILDING USE This facility will be used for Business, F-1, S-1 -no change of use proposed. FIRE RESISTANCE RATING REQ'TS FOR BUILDING ELEMENTS Structural Frame 0 HR Bearing Walls Exterior 0 HR Interior 0 HR Non Bearing Walls Exterior 0 HR Interior 0 HR Floor Construction N/A -Slab on Grade Roof Construction 0 HR • Stairs are not required to be enclosed (1009.3, exptn. 1) • Ductwork chase: A shaft enclosure is not required for penetrations by ducts protected in accordance with Section 714.4 (see also 717.6.3) • 714.4.2 Nonfire-resistance-rated assemblies. Penetrations of nonfire-resistance-rated floor or floor/ceiling assemblies or the ceiling membrane of a nonfire-resistance-rated roof/ceiling assembly shall meet the requirements of Section 713 or shall comply with Section 714.4.2.1 or 714.4.2.2 • 714.4.2.2 Penetrating items: Penetrating items that connect not more than two stories are permitted, provided that the annular space is filled with an approved material to resist the free passage of flame and the products of combustion. REQ'D SEPARATIONS CODE STRATEGY The following strategy is being used to approach the life safety code concerns for this building: The scope or work consists of renovating and existing office space. No change of occupancy or use is being proposed. ENERGY CODE SUMMARY • 2010 Indiana Energy Conservation Code; comprised of : - ASHRAE 90.1 2007 - 675 IAC 19.3 CODE LEGEND EXIT BRACKET MOUNTED PORTABLE FIRE EXTINGUISHER. VERIFY LOCATIONS AND QUANTITIES W/ APPLICABLE CODES, OWNER AND FIRE MARSHAL. FE NOTES: A. FIRE EXTINGUISHER LOCATIONS SHOWN ARE SUGGESTED LOCATIONS ONLY. LOCATIONS OF FIRE EXTINGUISHERS AND CABINETS SHALL COMPLY WITH NFPA 10. CONTRACTOR TO VERIFY QUANTITY AND EXACT LOCATIONS WITH AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. B. WHERE FIRE-RESISTANCE-RATED OR SMOKE-RESISTANCE-RATED WALLS EXTEND ABOVE A CEILING, SUCH WALLS SHALL BE PERMANENTLY AND APPROPRIATELY IDENTIFIED IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH IN THE BUILDING CODE. Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 4/7/2021 1:37:15 PM G102 SECOND FLOOR LIFE SAFETY PLAN 2021.00173 04/05/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS - PHASE 1 4518 WEST 99TH STREET CARMEL, IN 46032 N 1/16" = 1'-0" G102 1 SECOND FLOOR LIFE SAFETY PLAN REVISION SCHEDULE NO. DESCRIPTION DATE 04/26/21