HomeMy WebLinkAboutG102 2ND FL LIFE SAFETY PLAN1 2 3 4 5 6 7 8
D
E
C
B
A
CONFERENCE
204
OFFICE
205
OFFICE
203
OFFICE
202
OFFICE
201
OFFICE
207
OPEN
OFFICE
206
OFFICE
212
MECH
211
OFFICE
208
RR
210
RR
209
STAIR
ST-2
FE
78' -2"
EXISTING SPACE N.I.C.
APPLICABLE
BUILDING CODES
2014 Indiana Building Code, (2012 International Building Code & Local
Amendments)
2014 Indiana Fire Code, (2012 International Fire Code & Local
Amendments)
2009 Indiana Electrical Code, ()2008 National Electrical Code & Local
Amendments)
2014 Indiana Mechanical Code (2012 International Mechanical Code &
Local Amendments)
2012 Indiana Plumbing Code, (2006 International Plumbing Code &
Local Amendments)
OCCUPANCY
CLASSIFICATION
Business, F-1, S-1
CONSTRUCTION TYPE Type IIB
SPRINKLER SYSTEM Equipped throughout with an automatic sprinkler system in
accordance with 903.3.1.1 -exsiting system to remain.
LIFE SAFETY / BUILDING CODE SUMMARY
TRAVEL DISTANCE
RESTRICTIONS
• Dead-end Corridor Limit:50 ft (1018.4, ex. 2)
• Common Path of Travel:100 ft (Table 1014.03)
• Exit Travel Distance: F-1 & S-1 250 ft to exit access or exit
(Table 1016.2)
B 300 ft to exit access or exit
MISCELLANEOUS
REQUIREMENTS
• Two accessible exits required from 2nd floor (1007.1; 1015.1)
• Both Stairs can be unenclosed (1009.3, exptn. 1)
• No area of refuge required (1007.3, exptn. 2)
• Required stair width = 44" (1007.3, exptn. 1; 1009.4)
BUILDING USE This facility will be used for Business, F-1, S-1 -no change of use
proposed.
FIRE RESISTANCE
RATING REQ'TS FOR
BUILDING
ELEMENTS
Structural Frame 0 HR
Bearing Walls
Exterior 0 HR
Interior 0 HR
Non Bearing Walls
Exterior 0 HR
Interior 0 HR
Floor Construction N/A -Slab on Grade
Roof Construction 0 HR
• Stairs are not required to be enclosed (1009.3, exptn. 1)
• Ductwork chase: A shaft enclosure is not required for penetrations
by ducts protected in accordance with Section 714.4 (see also
717.6.3)
• 714.4.2 Nonfire-resistance-rated assemblies. Penetrations of
nonfire-resistance-rated floor or floor/ceiling assemblies or the
ceiling membrane of a nonfire-resistance-rated roof/ceiling
assembly shall meet the requirements of Section 713 or shall
comply with Section 714.4.2.1 or 714.4.2.2
• 714.4.2.2 Penetrating items: Penetrating items that connect not
more than two stories are permitted, provided that the annular
space is filled with an approved material to resist the free passage
of flame and the products of combustion.
REQ'D SEPARATIONS
CODE STRATEGY The following strategy is being used to approach the life safety code
concerns for this building:
The scope or work consists of renovating and existing office space. No
change of occupancy or use is being proposed.
ENERGY CODE
SUMMARY
• 2010 Indiana Energy Conservation Code; comprised of :
- ASHRAE 90.1 2007
- 675 IAC 19.3
CODE LEGEND
EXIT
BRACKET MOUNTED PORTABLE FIRE EXTINGUISHER.
VERIFY LOCATIONS AND QUANTITIES W/ APPLICABLE CODES,
OWNER AND FIRE MARSHAL.
FE
NOTES:
A. FIRE EXTINGUISHER LOCATIONS SHOWN ARE SUGGESTED LOCATIONS
ONLY. LOCATIONS OF FIRE EXTINGUISHERS AND CABINETS SHALL
COMPLY WITH NFPA 10. CONTRACTOR TO VERIFY QUANTITY AND EXACT
LOCATIONS WITH AUTHORITY HAVING JURISDICTION PRIOR TO
INSTALLATION.
B. WHERE FIRE-RESISTANCE-RATED OR SMOKE-RESISTANCE-RATED WALLS
EXTEND ABOVE A CEILING, SUCH WALLS SHALL BE PERMANENTLY AND
APPROPRIATELY IDENTIFIED IN ACCORDANCE WITH THE REQUIREMENTS
SET FORTH IN THE BUILDING CODE.
Project Number
CERTIFIED BY
ISSUANCE INDEX
DATE:
PROJECT PHASE:
4/7/2021 1:37:15 PM
G102
SECOND FLOOR LIFE
SAFETY PLAN
2021.00173
04/05/2021
CONSTRUCTION DOCUMENTS
ARTISTIC COMPOSITE
PALLETS - PHASE 1
4518 WEST 99TH
STREET CARMEL, IN
46032
N
1/16" = 1'-0"
G102
1 SECOND FLOOR LIFE SAFETY PLAN
REVISION SCHEDULE
NO. DESCRIPTION DATE
04/26/21