HomeMy WebLinkAboutCS1.0 Cover SheetRESPONSIBILITY SCHEDULE
CSI
DIV.
DISCLAIMER :
THE RESPONSIBILITY SCHEDULE IS NOT INTENDED TO DENOTE ALL RESPONSIBILITIES INVOLVED IN THE COMPLETION OF THIS PROJECT. THE GENERAL CONTRACTOR SHALL REVIEW ALL ATTACHED DOCUMENTATION
AND REVIEW EXISTING SITE CONDITIONS
PRIOR TO BID SUBMISSION. ALL CLARIFICATION AND QUESTIONS RELATED TO SCOPE OF WORK AND THIS RESPONSIBILITY SCHEDULE SHALL BE DIRECTED TO PHANOMEN/design, IN RFI FORM, PRIOR TO SUBMISSION
OF GENERAL CONTRACTOR'S BID.
DESCRIPTION
RESPONSIBILITY
FURNISHED BY GENERAL
CONTRACTOR
FURNISHED BY OWNER
UNDER SEPERATE CONTRACT
FURNISHED BY
PHANOMEN/design
INSTALLED BY GENERAL
CONTRACTOR
INSTALLED BY OWNER/
UNDER SEPERATE CONTRACT
1 PERMITS, FEES & INSURANCE
REMARKS
6 ROUGH CARPENTRY BLOCKING - AT ALL WALL-MOUNTED ITEMS
6 FINISH CARPENTRY MOLDINGS, BASES, MISCELLANEOUS TRIM - REFER TO ARCHITECTURAL DRAWINGS
7 WALL/CEILING INSULATION
7 FIRESTOPPING
7 JOINT SEALERS
5 DECORATIVE METAL/SCREENS; only if applicable in design scope
8 WOOD DOORS AND FRAMES
8 ACCESS DOORS AND PANELS (MEP)
8 ALL GLASS DOORS AND GLAZING SYSTEMS
8 DOOR HARDWARE
9 GYPSUM BOARD ASSEMBLIES
9 NON-STRUCTURL METAL FRAMING
9 FLOORING (LUXURY VINYL TILE, CARPET, VCT, PORCELAIN TILE)
9 ACOUSTICAL CEILINGS
9 PAINTING AND COATINGS
10
10 FIRE EXTINGUISHERS
12 FURNITURE: LOUNGE SEATING, DINING TABLES &CHAIRS & BOOTHS PER ARCHITECTURAL FF&E PLANS, PROVIDED AND INSTALLED BY PHANOMEN/design
21 SPRINKLER SYSTEM
22 WATER, WASTE, VENT REFER TO DRAWINGS. G.C. TO COORD. WITH LOCAL UTILITIES
22 CONDENSATE PIPING
PROVIDE AND INSTALL LINES; HEAT TRACE & INSULATION
22 WATER HEATER
23 RTU OR OTHER SIMILAR EQUIPMENT G.C. RESPONSIBLE FOR PROVIDING AND INSTALLING HVAC SYSTEM
23 DIFFUSERS, TEMP CONTROL, SMOKE DETECTION
23 AIR BALANCE G.C. TO PROVIDE CERTIFIED AIR BALANCE REPORT
23 TOILET EXHAUST
23 HVAC DUCTING (MATERIAL & INSTALL) G.C. TO PROVIDE & INSTALL EXHAUST DUCT WRAP & MAKEUP AIR DUCTS PER LOCAL REQUIREMENTS
26 DISTRUBUTION SYSTEM
26 PANELS / TRANSFORMER
26 GENERAL LIGHT FIXTURES
26 LIGHTING CONTROLS/SYSTEM (i.e. WATTSTOPPER SYSTEM)
27 PHONE & DATA CONDUITS G.C. TO PROVIDE & INSTALL ALL COMMUNICATION CONDUITS
27 PHONE & DATA WIRING
AS REQUIRED FOR EQUIPMENT FURNISHED BY OWNER'S VENDOR
27 PATCH PANEL FOR COMMUNICATION SYSTEM; only if applicable
28 FIRE LIFE SAFETY ALARMS DEFERRED SUBMITTAL - DESIGN BUILD, ALL PERMITS FOR ALARM SYSTEM TO BE APPLIED
FOR/OBTAINED BY G.C.
DESIGN BUILD, ALL PERMITS FOR SPRINKER SYSTEM TO BE APPLIED FOR/OBTAINED BY G.G.
28 SECURITY SYSTEM G.C. TO COORDINATE WITH SECURITY SYSTEM VENDOR. WIRING CONCEALED
WITHIN WALLS. TENANT/OWNER TO CONTRACT WITH SECURITY SYSTEM VENDOR
6 ARCHITECTURAL CASEWORK MOLDINGS, BASES, MISCELLANEOUS TRIM - REFER TO ARCHITECTURAL DRAWINGS
26 DECORATIVE LIGHT FIXTURES
12
12
12
12
12 WALLCOVERING
WINDOW TREATMENTS
ART & ACCESSORIES; STAGING ITEMS
RESTROOM HAND TOWEL TRAYS, MIRRORS, DECORATIVE SOAP DISHES
22 WATER SOFTENER GC TO COORDINATE ALL ALL ROUGH-INS FOR WATER SOFTENER AND INSTALLATION
BUILT-IN CABINETRY
RESTROOM GRAB BARS/TOILET (SANITARY) ACCESSORIES
22 FIRE TABLE (3RD FLOOR PATIO/ROOFTOP TERRACE) G.C. TO PROVIDE PROPANE FIRE TABLE, REQUIRED GLASS GUARD, AND BURNER
FILLER/MEDIUM. PHANOMEN TO PROVIDE FIRE TABLE SPECIFICATIONS AND PASS
INFORMATION ALONG TO G.C. FOR PROCUREMENT
-INSTALL ALL PRINTERS
-EXTERIOR SIGNAGE
- HANDLE ALL PERMITTING WITH CITY FOR EXTERIOR SIGNS
12 FURNITURE: INDIVIDUAL DOCTOR'S OFFICES
FURNISHED DIRECTLY
BY OWNER
GC TO COORDINATE ALL ALL ROUGH-INS FOR WATER HEATER AND INSTALLATION
12 FURNITURE: SYSTEMS FURNITURE FOR BACK OFFICE COORDINATE WITH PHANOMEN/design
9 WALL TILE
27 LOW VOLTAGE WIRING
-INDOOR AQUARIUM AND AQUARIUM SYSTEMS
COORDINATE WITH LANDLORD/DEVELOPER/GC
COORDINATE WITH GC. EXISTING AQUARIUM, SYSTEMS, AND MILLWORK TO BE
TRANSPORTED FROM OLD TENANT SUITE TO NEW SUITE
-INTERIOR SIGNAGE
- 'LIVING WALL' SYSTEM & COMPONENTS COORDINATE WITH PHANOMEN/design
11 APPLIANCES (REF., RANGE/HOOD, STOVE/COOKTOP, MICROWAVE)
11 RANGE HOOD (MATERIAL)
11 RANGE HOOD (THROUGH ROOF VENTING)
N/A
INSTALLED BY
PHANOMEN/design
G.C. TO RUN REQUIRED POWER TO ALL OUTLETS/JBOX LOCATIONS
- OFFICE MOVE MANAGEMENT COORDINATE WITH PHANOMEN/design
COORDINATE WITH PHANOMEN/design
8 METAL DOORS AND FRAMES
9 DECORATIVE CEILINGS
INSTALLED BY TBD
- EXISTING CONFERENCE ROOM TABLE & MEDIA CENTER CABINETRY COORDINATE WITH PHANOMEN/design
H
K
AQUARIUM
MAINTENANCE
13'4X3'10
AQUARIUM
MIKE
OFFICE 6
13'X10'
BREAK
ROOM
17'X13'4
LARGE CONF
ROOM
25'X13'
GENERAL
STORAGE
16'7 X 7'
BLOOD
DRAW
10'2 X 9'
M. PRIDDY
OFFICE 4
13'7'X14'
J. RIZZUTO
OFFICE 5
12'8 X 14'
EXAM 1
EX 1 21'3 X 18'
PATIENT RR
10'3X 8"
EXAM 2
20' X 19'7
EX 2
PATIENT RR
8'5 X 9'2
STORAGE
17' X 7'2 OFFICE 1
13'7X10' OFFICE 3
11'X14'
PHARMACY
& SAMPLES
11' X 9'9
OFFICE 7
15'X9'
MOLE MAPPING
(PHOTO FINDER)
10' x 9'8
STORAGE
7'6X8'5
JANITOR
5'7X8'2
EXAM 3
25'4X18'7
EX 3
PATIENT RR
8'5 X 8'2
LAB
20' X 11'7
PROCEDURE
ROOM
16'3 X 8'5
OFFICE 8
12'2X13'
UNISEX
RESTROOM
10'1X9'9
EXAM 10
PEDIATRIC
9'2X22'
EX PED
PATIENT RR
10'2"X9'
EX 4
PATIENT RR
8'5 X 8'2
OFFICE 9
15'4X12'2
OFFICE 10
15'X10'
EXAM 5
18'5X18'7
PROCEDURE &
BLOOD DRAW
18'5X8'3
SHOWER
ROOM
15'3X8'2
EXAM 9
20'X18'3
EX 9
PATIENT RR
10'X7'8
EXAM 8
24'7x17'3
EX 8
PATIENT RR
8'5 X 8'6
EXAM 4
17'8X18'7
EX 5
PATIENT RR
8'5 X 8'2
EX 6
PATIENT RR
8'5 X 8'2
EX 7
PATIENT RR
8'5 X 8'2
EXAM 6
21'2X18'7
EXAM 7
24'6X18'7
OFFICE 2
14'2X10'
BUILDING CODE:
2014 INDIANA BUILDING CODE (2012
INTERNATIONAL BUILDING CODE: 675 IAC 13-2.5)
PLUMBING CODE:
2012 INDIANA PLUMBING CODE (1997 UNIFORM
PLUMBING CODE: 675 IAC 16-1.3)
ELECTRICAL CODE:
2009 INDIANA ELECTRICAL CODE (2008 NFPA-70:
675 IAC 17-1.7)
MECHANICAL CODE:
2014 INDIANA MECHANICAL CODE (2012
INTERNATIONAL MECHANICAL CODE: 675 IAC
18-1.5)
FIRE/ LIFE SAFETY CODE:
2014 INDIANA FIRE CODE (2012 INTERNATIONAL
FIRE CODE: 675 IAC 22-2.4)
ACCESSIBILITY CODE:
2008 INDIANA BUILDING CODE CHAPTER 11 -
ACCESSIBILITY (675 IAC 13-2.5-12 CHAPTER 11)
ENERGY CODE:
2010 INDIANA ENERGY CONSERVATION CODE
(ASHRAE 90.1, 2007 EDITION)
ELEVATOR CODE:
2006 INDIANA ELEVATOR SAFETY CODE
GAS CODE:
2014 INDIANA FUEL GAS CODE (2012
INTERNATIONAL FUEL GAS CODE: 675 IAC 25-2)
SANITARY CODE:
1998 AMERICAN SOCIETY OF SANITARY
ENGINEERS STANDARD 1051: 675 IAC 16-2)
PROJECT SCOPE:
Project includes the initial tenant build-out of the third floor of a primary
care medical office. The existing shell of the building was separately
submitted and is outside the scope of these documents.
BUILDING DESCRIPTION:
TYPE 'B' OCCUPANCY
CONSTRUCTION TYPE CLASSIFICATION:
TYPE II-B - SPRINKLERED
FIRE RESISTANCE RATING REQUIREMENTS:
STRUCTURAL FRAME: NONFLAMMABLE (EXISTING)
EXTERIOR BEARING WALLS: NONFLAMMABLE (EXISTING)
NONBEARING WALLS & PARTITIONS: ANY MATERIAL
TENANT SEPARATION: (EXISTING)
SHAFT ENCLOSURES: (EXISTING)
STAIR ENCLOSURES: (EXISTING)
ACTUAL AREA: 14,042 SF
OFFICE 'B' OCCUPANCY: 12,045.67 SF/ 100 = 120.46 OCC.
CONFERENCE 'A' OCCUPANCY: 396.8 SF/ 15 = 26.46 OCC.
STORAGE OCCUPANCY: 618.45 SF/ 500 = 1.24 OCC.
PATIO OCCUPANCY: 981.34 SF/ 15 = 65.42 OCC.
TOTAL MAX. OCCUPANCY: 213.58 OR 214 OCCUPANTS
EXIT ANALYSIS:
14,832 SF (TYPE 'B' OCCUPANCY) WITH A TOTAL OCCUPANT LOAD OF
214, PER IBC TABLE 1014.1, SHALL HAVE A MINIMUM OF TWO (2) EXITS.
TWO (2) EXITS HAVE BEEN PROVIDED.
MAXIMUM COMMON PATH OF TRAVEL DISTANCE: 100 FT
MAXIMUM EXIT ACCESS TRAVEL DISTANCE: 300 FT
EGRESS ANALYSIS:
214 OCCUPANTS X .15 (2014 INDIANA BUILDING CODE TABLE 1005.1) =
32.1"
PER IBC 1020.2, 44" MINIMUM REQUIRED WIDTH, 72" PROVIDED.
RESTROOM ANALYSIS:
TOTAL OCCUPANTS = 214
1 FIXTURE PER 25 OCCUPANTS REQUIRED FOR FIRST 50 OCCUPANTS AND 1
FIXTURE REQUIRED FOR EACH REMAINING 50 OCCUPANTS THEREAFTER
TOTAL OF 6 FIXTURES REQUIRED, 12 FIXTURES PROVIDED
1 LAVATORY PER 40 OCCUPANTS REQUIRED FOR FIRST 80 OCCUPANTS
AND 1 LAVATORY REQUIRED FOR EACH REMAINING 80 OCCUPANTS
THEREAFTER
TOTAL OF 4 LAVATORIES REQUIRED, 12 LAVATORIES PROVIDED
N
S
W
E
DRAWING INDEX
INTERIOR DESIGN:
PHANOMEN/design
934 FT. Wayne Ave.
Indianapolis, IN 46202
O (317) 439-4355
TENANT/OWNER:
PRIORITY PHYSICIANS
8333 Naab Road, Suite 360
Indianapolis, IN 46260
O (317) 338-6400
DR. MATTHEW PRIDDY - HEAD PHYSICIAN
JOE RIZZUTO - CHIEF OPERATING OFFICER
ELECTRICAL CONTRACTOR:
ERMCO, INC.
1625 W. Thompson Road
Indianapolis, IN 46217
D (317) 396-4987
DREW POJAR
PROJECT TEAM VICINITY MAP
APPLICABLE CODES
DEVELOPER/OWNER/GC
CORNERSTONE COMPANIES
8902 N. Meridian Street
Indianapolis, IN 46260
O (317) 841-9900
JEFF SHIVELY - DEVELOPMENT
STEPHEN OESTERREICH - CONSTRUCTION
BRANDI HANEY
BRANDON LOWRY
AREA OF WORK
(THIRD FLOOR)
TENANT IT VENDOR
BROOKFIELD GROUP
12400 N. Meridian Street, Suite 180
Carmel, IN 46032
(317) 524-6021 (Desk)
CHRIS KENYON
PRIORITY PHYSICIANS
CARMEL ARTS MEDICAL PAVILION
12174 N. MERIDIAN STREET
SUITE 300 (3RD FLOOR)
CARMEL, IN 46032
GENERAL INFORMATION
GN1.0 PROJECT DATA, GENERAL NOTES, LEGENDS
LS1.1 LIFE SAFETY PLAN
ARCHITECTURAL/INTERIORS
A1.1 ANNOTATED FLOOR PLAN
A1.2 DIMENSIONED ARCHITECTURAL PLAN & WALL TYPES
A1.3
A1.4 REFLECTED CEILING PLAN & LIGHTING LEGEND
A1.5 DIMENSIONED REFLECTED CEILING PLAN (NOT INCLUDED IN THIS SET)
A1.6 ENLARGED RESTROOM PLANS & ELEVATIONS
A1.7 DOOR TYPES & SCHEDULE
A1.8 WINDOW WALL TYPES & DETAILS
Certified By:
Scale:
Date:
Checked By:
Drawn By:
Job Number:
Drawing Number:
Drawing Name:
CARMEL, IN 46032
01.22.2021
www.phanomen.com
934 Fort Wayne Ave. - Indianapolis, IN 46202
317.439.4355 (t)
PRIORITY PHYSICIANS ...creating profitable environments...
Revisions:
12174 N. MERIDIAN
SUITE 300
AS NOTED
BSH
LOE
COVER SHEET
CS1.0
PROJECT LOCATION
CS1.0 COVER SHEET
PERMIT SET 01.22.2021
MECHANICAL AND PLUMBING
CONTRACTOR
TPC MECHANICAL CONTRACTORS
P.O. Box 3160
Carmel, IN 46082
O (317) 846-4768
TERRY WILDS
CHRIS WILDS
LARRY PHILLIPS
VERDANT ENGINEERING
MARK NORDMEYER
D (317) 446-1651
IN WALL BLOCKING PLAN
F1.1
F1.3 INTERIOR ELEVATIONS (NOT INCLUDED IN THIS SET)
THIRD FLOOR KEY PLAN
NOT TO SCALE
N
S
W
E
CODE SUMMARY
SHEET # SHEET NAME
SHEET # SHEET NAME
MECHANICAL/ELECTRICAL/PLUMBING
SHEET # SHEET NAME
PRELIMINARY FINISH PLAN & LEGEND
F1.4 INTERIOR ELEVATIONS (NOT INCLUDED IN THIS SET)
F1.5 INTERIOR ELEVATIONS (NOT INCLUDED IN THIS SET)
F1.6 INTERIOR ELEVATIONS (NOT INCLUDED IN THIS SET)
F1.7 INTERIOR SECTIONS (NOT INCLUDED IN THIS SET)
F1.8 INTERIOR SECTIONS (NOT INCLUDED IN THIS SET)
RESPONSIBILITY SCHEDULE
F1.2 INTERIOR ELEVATIONS (NOT INCLUDED IN THIS SET)
ELECTRICAL ENGINEER:
GENESIS ENGINEERING
91 S. Main Street, Suite 200
Zionsville, IN 46077
O (317) 927-8307
JOSH WALKE
AQUARIUM SERVICE COMPANY:
AQUARIUM SERVICE & DESIGN
C (317) 416-8791
GLENN KANT
A1.9 INTERIOR & CEILING DETAILS
M001 MECHANICAL SYMBOLS AND ABBREVIATIONS
MECHANICAL
M202 SECOND FLOOR MECHANICAL PLAN
M203 THIRD FLOOR MECHANICAL PLAN
M204 ROOF MECHANICAL PLAN
M500 MECHANICAL SCHEDULES
M600 MECHANICAL DETAILS
P001 PLUMBING SYMBOLS AND ABBREVIATIONS
PLUMBING
P101 PLUMBING SANITARY WASTE UNDERSLAB PLAN
P102 PLUMBING SANITARY WASTE & VENT ABOVESLAB PLAN
P201 PLUMBING DOMESTIC WATER PLAN
P401 PLUMBING SANITARY WASTE UNDERSLAB ENLARGED PLAN
P402 PLUMBING SANITARY WASTE UNDERSLAB ENLARGED PLAN
P403 PLUMBING SANITARY WASTE & VENT ABOVESLAB ENLARGED PLAN
P404 PLUMBING SANITARY WASTE & VENT ABOVESLAB ENLARGED PLAN
P405 PLUMBING DOMESTIC WATER ENLARGED PLAN
P406 PLUMBING DOMESTIC WATER ENLARGED PLAN
P501 PLUMBING DETAILS
P601 PLUMBING SANITARY WASTE & VENT ISOMETRIC PLAN
P602 PLUMBING DOMESTIC WATER ISOMETRIC PLAN
P701 PLUMBING SCHEDULES
E001 ELECTRICAL SYMBOLS
ELECTRICAL
E203.31 THIRD LEVEL LIGHTING PLAN
E303.31 THIRD LEVEL POWERSYSTEMS PLAN
E303A.31 THIRD LEVEL HVAC POWER PLAN
E304.31 ROOF POWERSYSTEMS PLAN
E501 ELECTRICAL ONELINE RISER DIAGRAM
E604 ELECTRICAL SCHEDULES
E802 ELECTRICAL DETAILS
BRIAN ABEL
MECHANICAL ENGINEER