HomeMy WebLinkAboutE303.31 - THIRD LEVEL POWERSYSTEMS PLAN -TENANT 31SD
H
H
SD
HD
SD
HD
J
CRCR
VF1
VF2 (NEW)
AQUARIUM
MAINT.
302
AQUARIUM
MIKE
OFFICE 6
331
BREAK
ROOM
318
CONFERENCE
ROOM
316
MEDICAL
STORAGE
334
BLOOD
DRAW
303
M. PRIDDY
OFFICE 4
338
J. RIZZUTO
OFFICE 5
339
EXAM 1
306A
EX 1
PATIENT RR
306B
EXAM 2
307A
EX 2
PATIENT RR
307B
GENERAL
STORAGE
332
OFFICE 1
335
OFFICE 3
337
PHARMACY
& SAMPLES
304
OFFICE 7
330
MOLE MAPPING
(PHOTO FINDER)
329
STORAGE
305
JANITOR
328
EXAM 3
308A
EX 3
PATIENT RR
308B
LAB
322
PROCEDURE
ROOM
317
OFFICE 8
327
UNISEX
RESTROOM
319
EXAM 10
PEDIATRIC
315A
EX PED
PATIENT RR
315B
EX 4
PATIENT RR
309B
OFFICE 9
326
OFFICE 10
325
EXAM 5
310A
PROCEDURE &
BLOOD DRAW
323
SHOWER
ROOM
320
EXAM 9
314A
EX 9
PATIENT RR
314B
EXAM 8
313A
EX 8
PATIENT RR
313B
EXAM 4
309A
EX 5
PATIENT RR
310B
EX 6
PATIENT RR
311B
EX 7
PATIENT RR
312B
EXAM 6
311A
EXAM 7
312A
OFFICE 2
336
RECEPTION
300
WAITING LOUNGE
301
SOILED
LINENS
321
STORAGE
324
BACK HALL
333
OPEN
OFFICE
340
HALLWAY
341
HALLWAY
342
HALLWAY
343
HALLWAY 344
344
HALLWAY
345
HALLWAY
346
EXISTING
STAIR 2
NIC
EXISTING
STAIR 1
NIC
DN
DN
ELEC. ROOM
(EXIST.)
NIC
Q
c
RACK2
RACK3 RACK3
RACK4
RACK6
RACK7
STORCAB2
RACK2
RACK4
ET1
T7
ET1
DSK
CH3
CH2
CH2
T8
SOFA2
CH5
DSK
MTLCHEST1
RACK1 STORCART1
ET1
EQUIP1
EQUIP2
DSK
TREADMILL1
STORCART2
ECH1
ET1
T10
ET1
ET1 ET1
ET1 ET1 ET1
ET1
DW
MF
MF
B.5
H
J
1 5 9
B
2 4 7
C
E
6 8.8
F.4
A
1.2
D
3 8
G
F.3
F
D.2
G.1
H.5
4.5 5.5 7.1 8.5
H
H
OC
J
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
J
FSR
WP
WPWPWP
J
J
J
V
V
V
V
V
H
H
H
H
H
H
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
H
H
V V
V
J J J J
J
J
J
J
J
J
J
J
J J J J J J J
J
J
J
J J J J J J
J
J
J
K
K
K
J
J
J
J
J
ATS
3L2
3H1
T-3L1
3L1
1 2
3
4
5
6
7
8
9
10
11
7
6
3L1-14
3L1-14
3L1-14
3L1-14
3L1-14
+54" +72"
3L1-16
3L1-20
3L1-18
3L1-20
3L1-20
3L1-20
3L1-22
3L1-22
3L1-22
3L1-22
3L1-22 3L1-22
3L1-24
3L1-24
3L1-2626 3L1-
3L1-26
3L1-26
3L1-2626 3L1-263L1-
3L1-28
3L1-28
3L1-28
3L1-28
3L1-2832 3L1-
3L1-32
3L1-28
3L1-3232 3L1-
3L1-78
3L1-24
3L1-30
3L1-32
3L1-38 3L1-38
3LE1-2
3L1-38
3L1-38
3L1-40
3L1-4040 3L1-
3L1-40
3L1-4040 3L1-
3L1-38
3L1-38
3L1-62
3L1-62
3L1-60
3L1-42 3L1-42
3LE1-4
3L1-32
3L1-3278 3L1-
3L1-32
3L1-4444 3L1-
3L1-44
3L1-44
3L1-44
3L1-78
3L1-44
3L1-44
3L1-44
3L1-44
3L1-36
3L1-36
3L1-78
3L1-3636 3L1-
3L1-36
3L1-36
3L1-36
3L1-49
3L1-49
3L1-49
3L1-49
3L1-64
3L1-51
3L1-4949 3L1-
3L1-49
3L1-49
3L1-53
3L1-53
3L1-51
3L1-59
3L1-43
3L1-64
3L1-43
3L1-43
3L1-43
3L1-64
3L1-64
3L1-64
3L1-62
3L1-62
3L1-59
3L1-51
3L1-55 3L1-55 3L1-53 3L1-53
3L1-55 3L1-53
3L1-5355 3L1-
3L1-55
3L1-55
3L1-55
3L1-61 3L1-61 3L1-61
3L1-61
3L1-61
3L1-59
3L1-57
3LE1-3
3L1-63
3L1-63
3L1-61
3L1-61
3L1-63
3L1-63
3L1-45
3L1-45
3L1-45
3L1-47
3L1-45
3L1-67
3L1-67
3L1-67
3LE1-13
3LE1-17 3LE1-17
3LE1-15
3LE1-15
3L1-65
3L1-67
3L1-35
3L1-35
3L1-33
3L1-33
3L1-35
3L1-33
3LE1-1
3L1-33
3L1-33
3L1-33
3L1-31
3L1-31
3L1-31
3L1-31
3L1-74
3L1-31
3L1-74 3L1-74
3L1-58
3L1-66
3L1-58
3L1-56
3L1-50 3L1-50
3L1-58
3L1-58
3L1-46
3LE1-16
+33"
3L1-26
3L1-26
3L1-28 3L1-28
3L1-28
3L1-76
3L1-76 3L1-76 3L1-76
3L1-42
3L1-66
3L1-66
3L1-66
3L1-66
3L1-31
3L1-33
3L1-33
3L1-37,39,41 3L1-68,70,72
3L1-53
3L1-62
3L1-62
3L1-64
3L1-64
3L1-45
3L1-45
3L1-47
3L1-60
3L1-60
3L1-50
3L1-46
3L1-48
REF.
F50
3L1-52,54
3L1-58
+60"
+66"
+50" +18"
+50" +18"
+50" +18"
+50"
+18"
+50"
+18"
+50"
+18"
+50"
+18"
+50"
+18"
+50"
+18"
+18" +50"
+66"
+66"
+66"
+60"
+18"
+18"
+50"
REF.
+66"
+38"
+38"
+38"
+88" +88"+32"
REF.
PT1
PT2
12
11
3LE1-5
+66"
+66"
2
11
3LE1-8
3L1-22
PT3
3LE1-6
+10"
+10"
+10"
3L1-29
3L1-29
3L1-29
3L1-27
3L1-69
3H1- 20,22,24,
3H1- 14,16,18,
3L1-22
3L1-26
3L1-28
3L1-61
3LE1-14
3LE1-11
+32" +32"
13
13
3LE1
14
3L1-7
3L1-42
15
15
15
1524 3L1-15
3L1-9
15
3L1-40
15
15
15
1515
1515
15
1515
15
15
15
15
15
3L1-43
15
15
15
16
16
16
FLOOR BOX SCHEDULE
NAME DESCRIPTION MODEL COMMENTS
PT1
PT2
POWER, DATA, AV
POWER AND DATA
SEE NOTE 1 , 2, 4
SEE NOTE 1, 3
S1R6PTWZXXX
S1R6PTACEHXXX
NOTES:
1. XXX COVER FINISH TO BE SELECTED BY OWNER OR ARCHITECT.
2. SUBPLATES TO BE DETERMINED.
3. 1-20A PREWIRED SUBPLATE ARE INCLUDED AS WELL AS SUBPLATES FOR DATA.
4. 1-20A PREWIRED SUBPLATE IS INCLUDED AS WELL AS SUBPLATES FOR DATA AND AV.
PT31 FURNITURES1R6PTFFXXX FEED WITH POWER AND DATA SEE NOTE
www.phanomen.com
934 Fort Wayne Ave. - Indianapolis, IN 46202
317.439.4355 (t)
...creating profitable environments.. .
Project Number
CERTIFIED BY
ISSUANCE INDEX
DATE:
PROJECT PHASE:
PRIORITY
PHYSICIANS
2/11/2021 10:05:21 AM
E303.31
THIRD LEVEL
POWER/SYSTEMS
PLAN -TENANT 31
2019.00780
11.5.2020
CONSTRUCTION DOCUMENTS
CARMEL MEDICAL
ARTS PAVILION
12174 N. Meridian Street
Carmel, Indiana 46032
1/8" = 1'-0"
1
THIRD LEVEL POWER/SYSTEMS PLAN - TENANT 31
PLAN NOTES
1 INSTALL RECEPTACLES AND DATA OUTLET IN AT 10" A.F.F. TO CENTER, ROUTE (1) 3/4" C
FOR POWER AND (1) 1' 1/4" C FOR DATA FROM NEAREST WALL DOWN TO ABOVE 2ND
FLOOR CEILING AND STUBBED UP INTO CASEWORK. COORDINATE CASEWORK INSTALL
WITH CASEWORK SUPPLIER.
2 PROVIDE DUPLEX RECEPTACLE ABOVE ACCESSIBLE CEILING FOR OWNER PROVIDE EXAM
LIGHT.
3 INSTALL DEVICE HORIZONTALLY AT 51.5" A.F.F. AND 19" FROM OUTER EDGE OF EXISTING
BUILT-IN CABINET.
4 PROVIDE POKE THRU FLOOR BOX, (1) 1' 1/2" CONDUIT ABOVE 2ND FLOOR CEILING AND
WALL MOUNTED MONITOR BACKBOX. REFER TO DETAIL ON SHEET EXXX.
5 STUB UP CONDUIT INTO CASEWORK, EXTEND (2) 3/4" ABOVE 2ND FLOOR CEILING AND UP
NEAREST WALL. PROVIDE CONNECTION TO COOKTOP AND RECEPTACLE.
6 PROVIDE CONNECTION TO OWNER PROVIDED FURNITURE SYSTEM. COORDINATE
FURNITURE WHIP WITH PROVIDER.
7 PROVIDE (1) 2" CONDUIT STUBBED UP NEAREST WALL FOR DATA.
8 INSTALL DEVICE(S) 1'-0" BELOW THE CEILING.
9 PROVIDE CIRCUIT IN J-BOX ABOVE CEILING FOR FUTURE LOGO SIGN LIGHT.
10 PROVIDE UNDER COUNTER RECEPTACLE FOR DISHWASHER.
11 PROVIDE SINGLE GANG BACKBOX AND (1) 3/4" C STUBBED UP ABOVE CEILING FOR
REFRIGERATOR ALARM CIRCUIT.
12 INSTALL AT 72" A.F.F. FOR PERGOLA HEATER CONTROL PANEL. CONTRACTOR TO
COORDINATE EXACT POWER REQUIREMENTS AND WIRING WITH MANUFACTURER.
13 ROUTE CIRCUIT THROUGH HEATER CONTROL PANEL.
14 PROVIDE CONNECTION TO KITCHEN HOOD.
15 PROVIDE UNDERCOUNTER SINGLE GANG BACKBOX WITH COVER FOR HARDWIRED
CONNECTION TO TOUCHLESS FAUCET SYSTEM. CONNECT TO LOAD SIDE OF GFCI.
COORDINATE INSTALLATION WITH CASEWORK AND FAUCET MANUFACTURER.
16 PROVIDE ROUGH-IN FOR KEYPAD. COORDINATE INSTALLATION AND POWER
REQUIREMENTS WITH SYSTEM PROVIDER/INSTALLER.
GENERAL NOTES
A. REFER TO DRAWING E001 FOR ELECTRICAL SYMBOLS AND ADDITIONAL GENERAL NOTES.
B. COORDINATE ALL WORK WITH THE OWNER AND THE OTHER TRADES ON THE PROJECT.
C. REFER TO M AND P SERIES DRAWINGS FOR ADDITIONAL ELECTRICAL REQUIREMENTS.
D. PROTECT ALL FINISHES, EQUIPMENT, AND DEVICES DURING THE WORK.
E. REFER TO ARCHITECTURAL SCHEDULES, DETAILS, AND ELEVATIONS FOR ADDITIONAL
INFORMATION ON DEVICE LOCATIONS PRIOR TO ROUGH-IN. COORDINATE LUMINAIRE
INSTALLATION AND QUANTITIES WITH ARCHITECTURAL DRAWINGS.
F. COORDINATE ALL WORK WITH THE OWNER'S SYSTEMS VENDORS FOR DEVICES AND
WIRING FOR DATA, I.T. SERVICES, AND SECURITY SYSTEMS.
G. ELECTRICAL SERVICES SHALL NOT ROUTE THROUGH ANY IDF OR MDF ROOM UNLESS
DIRECTLY SERVING THAT \ ROOM.
H. CONTRACTOR SHALL VERIFY CORD AND PLUG CONNECTED EQUIPMENT CORD
CONFIGURATION AND PROVIDE MATCHING RECEPTACLE AS REQUIRED.
I. ALL RECEPTACLES WITHIN SIX FEET OF A SINK SHALL BE GFCI TYPE. DEVICES MAY NOT BE
IDENTIFIED AS GFCI ON PLANS, BUT SHALL BE PROVIDED ACCORDING TO THE
REQUIREMENT.
J. ALL SPECIAL TYPE RECEPTACLES SHALL BE NEMA 6-20R UNLESS NOTED OTHERWISE AND
SHALL BE CIRCUITED WITH (2) #10 + (1) #10 NEUTRAL + (1) #10 GROUND. COORDINATE
REQUIREMENTS WITH OWNER SUPPLIED EQUIPMENT PRIOR TO INSTALLATION.
K. COORDINATE INSTALLATION OF LIGHT FIXTURES WITH ARCHITECTURAL REFLECTED
CEILING PLAN, ARCHITECTURAL ELEVATIONS, HVAC EQUIPMENT, DIFFUSERS, DUCTWORK,
PIPING, SUPPORTS, AND STRUCTURE PRIOR TO ROUGH-IN.
L. ALL EXIT SIGNS, EMERGENCY BATTERY LIGHTING UNITS, AND LIGHT FIXTURES SHOWN
WITH EMERGENCY BATTERY BACKUP OR INDICATED AS A NIGHT LIGHT ("NL") SHALL BE
PROVIDED WITH AN UNSWITCHED "HOT" CIRCUIT CONDUCTOR.
M. AT LOCATIONS WITH TWO OR MORE WALL SWITCHES, ALL SWITCHES SHALL BE INSTALLED
GANGED IN A COMMON SWITCH BOX.
N. AT LOCATIONS WHERE LIGHT SWITCHES AND ABOVE-COUNTER RECEPTACLES ARE TO BE
MOUNTED ADJACENT TO EACH OTHER, THE DEVICES SHALL BE INSTALLED AT THE SAME
HEIGHT.
O. WHERE OCCUPANCY SENSORS ARE INDICATED ON PLANS, THE ENTIRE ROOM SHALL BE
COVERED. SENSOR MANUFACTURER IS RESPONSIBLE FOR SENSOR LAYOUT.
ADDITIONAL SENSORS REQUIRED DUE TO LACK OF COVERAGE SHALL BE THE
RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. PROVIDE QUANTITIES AS
REQUIRED. CEILING AND WALL MOUNTED SENSORS SHALL BE DUAL-TECHNOLOGY TYPE.
SENSORS SHALL INCLUDED ALL POWER SUPPLIES AND RELAYS NECESSARY TO CONTROL
LIGHT FIXTURES IN ROOM/AREA. SENSORS SHALL OPERATE IN "VACANCY" MODE -
MANUAL ON/AUTO OFF.
P. PROVIDE PULL STRING IN ALL EMPTY CONDUITS.
Q. CONTRACTOR TO PROVIDE ROUGH-INS ONLY FOR DATA, I.T. SERVICES, AND SECURITY
SYSTEMS. DATA, I.T. SERVICES, AND SECURITY SYSTEMS DEVICES AND WIRING TO BE
PROVIDED BY THE OWNERS SYSTEMS VENDORS. PROVIDE ROUGH-INS WITH "RING AND
STRING".
R. COORDINATE DIMMING COMPATIBILITY WITH LED LUMINAIRE MANUFACTURER.
S. INSTALL ALL SWITCHES AND DIMMERS AT +48" A.F.F. UNLESS NOTED OTHERWISE.
REVISION SCHEDULE
NO. DESCRIPTION DATE