HomeMy WebLinkAboutE303.31 - THIRD LEVEL POWERSYSTEMS PLAN -TENANT 31SD H H SD HD SD HD J CRCR VF1 VF2 (NEW) AQUARIUM MAINT. 302 AQUARIUM MIKE OFFICE 6 331 BREAK ROOM 318 CONFERENCE ROOM 316 MEDICAL STORAGE 334 BLOOD DRAW 303 M. PRIDDY OFFICE 4 338 J. RIZZUTO OFFICE 5 339 EXAM 1 306A EX 1 PATIENT RR 306B EXAM 2 307A EX 2 PATIENT RR 307B GENERAL STORAGE 332 OFFICE 1 335 OFFICE 3 337 PHARMACY & SAMPLES 304 OFFICE 7 330 MOLE MAPPING (PHOTO FINDER) 329 STORAGE 305 JANITOR 328 EXAM 3 308A EX 3 PATIENT RR 308B LAB 322 PROCEDURE ROOM 317 OFFICE 8 327 UNISEX RESTROOM 319 EXAM 10 PEDIATRIC 315A EX PED PATIENT RR 315B EX 4 PATIENT RR 309B OFFICE 9 326 OFFICE 10 325 EXAM 5 310A PROCEDURE & BLOOD DRAW 323 SHOWER ROOM 320 EXAM 9 314A EX 9 PATIENT RR 314B EXAM 8 313A EX 8 PATIENT RR 313B EXAM 4 309A EX 5 PATIENT RR 310B EX 6 PATIENT RR 311B EX 7 PATIENT RR 312B EXAM 6 311A EXAM 7 312A OFFICE 2 336 RECEPTION 300 WAITING LOUNGE 301 SOILED LINENS 321 STORAGE 324 BACK HALL 333 OPEN OFFICE 340 HALLWAY 341 HALLWAY 342 HALLWAY 343 HALLWAY 344 344 HALLWAY 345 HALLWAY 346 EXISTING STAIR 2 NIC EXISTING STAIR 1 NIC DN DN ELEC. ROOM (EXIST.) NIC Q c RACK2 RACK3 RACK3 RACK4 RACK6 RACK7 STORCAB2 RACK2 RACK4 ET1 T7 ET1 DSK CH3 CH2 CH2 T8 SOFA2 CH5 DSK MTLCHEST1 RACK1 STORCART1 ET1 EQUIP1 EQUIP2 DSK TREADMILL1 STORCART2 ECH1 ET1 T10 ET1 ET1 ET1 ET1 ET1 ET1 ET1 DW MF MF B.5 H J 1 5 9 B 2 4 7 C E 6 8.8 F.4 A 1.2 D 3 8 G F.3 F D.2 G.1 H.5 4.5 5.5 7.1 8.5 H H OC J WAP WAP WAP WAP WAP WAP WAP WAP J FSR WP WPWPWP J J J V V V V V H H H H H H V V V V V V V V V V V V V V V V V V V V H H V V V J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J K K K J J J J J ATS 3L2 3H1 T-3L1 3L1 1 2 3 4 5 6 7 8 9 10 11 7 6 3L1-14 3L1-14 3L1-14 3L1-14 3L1-14 +54" +72" 3L1-16 3L1-20 3L1-18 3L1-20 3L1-20 3L1-20 3L1-22 3L1-22 3L1-22 3L1-22 3L1-22 3L1-22 3L1-24 3L1-24 3L1-2626 3L1- 3L1-26 3L1-26 3L1-2626 3L1-263L1- 3L1-28 3L1-28 3L1-28 3L1-28 3L1-2832 3L1- 3L1-32 3L1-28 3L1-3232 3L1- 3L1-78 3L1-24 3L1-30 3L1-32 3L1-38 3L1-38 3LE1-2 3L1-38 3L1-38 3L1-40 3L1-4040 3L1- 3L1-40 3L1-4040 3L1- 3L1-38 3L1-38 3L1-62 3L1-62 3L1-60 3L1-42 3L1-42 3LE1-4 3L1-32 3L1-3278 3L1- 3L1-32 3L1-4444 3L1- 3L1-44 3L1-44 3L1-44 3L1-78 3L1-44 3L1-44 3L1-44 3L1-44 3L1-36 3L1-36 3L1-78 3L1-3636 3L1- 3L1-36 3L1-36 3L1-36 3L1-49 3L1-49 3L1-49 3L1-49 3L1-64 3L1-51 3L1-4949 3L1- 3L1-49 3L1-49 3L1-53 3L1-53 3L1-51 3L1-59 3L1-43 3L1-64 3L1-43 3L1-43 3L1-43 3L1-64 3L1-64 3L1-64 3L1-62 3L1-62 3L1-59 3L1-51 3L1-55 3L1-55 3L1-53 3L1-53 3L1-55 3L1-53 3L1-5355 3L1- 3L1-55 3L1-55 3L1-55 3L1-61 3L1-61 3L1-61 3L1-61 3L1-61 3L1-59 3L1-57 3LE1-3 3L1-63 3L1-63 3L1-61 3L1-61 3L1-63 3L1-63 3L1-45 3L1-45 3L1-45 3L1-47 3L1-45 3L1-67 3L1-67 3L1-67 3LE1-13 3LE1-17 3LE1-17 3LE1-15 3LE1-15 3L1-65 3L1-67 3L1-35 3L1-35 3L1-33 3L1-33 3L1-35 3L1-33 3LE1-1 3L1-33 3L1-33 3L1-33 3L1-31 3L1-31 3L1-31 3L1-31 3L1-74 3L1-31 3L1-74 3L1-74 3L1-58 3L1-66 3L1-58 3L1-56 3L1-50 3L1-50 3L1-58 3L1-58 3L1-46 3LE1-16 +33" 3L1-26 3L1-26 3L1-28 3L1-28 3L1-28 3L1-76 3L1-76 3L1-76 3L1-76 3L1-42 3L1-66 3L1-66 3L1-66 3L1-66 3L1-31 3L1-33 3L1-33 3L1-37,39,41 3L1-68,70,72 3L1-53 3L1-62 3L1-62 3L1-64 3L1-64 3L1-45 3L1-45 3L1-47 3L1-60 3L1-60 3L1-50 3L1-46 3L1-48 REF. F50 3L1-52,54 3L1-58 +60" +66" +50" +18" +50" +18" +50" +18" +50" +18" +50" +18" +50" +18" +50" +18" +50" +18" +50" +18" +18" +50" +66" +66" +66" +60" +18" +18" +50" REF. +66" +38" +38" +38" +88" +88"+32" REF. PT1 PT2 12 11 3LE1-5 +66" +66" 2 11 3LE1-8 3L1-22 PT3 3LE1-6 +10" +10" +10" 3L1-29 3L1-29 3L1-29 3L1-27 3L1-69 3H1- 20,22,24, 3H1- 14,16,18, 3L1-22 3L1-26 3L1-28 3L1-61 3LE1-14 3LE1-11 +32" +32" 13 13 3LE1 14 3L1-7 3L1-42 15 15 15 1524 3L1-15 3L1-9 15 3L1-40 15 15 15 1515 1515 15 1515 15 15 15 15 15 3L1-43 15 15 15 16 16 16 FLOOR BOX SCHEDULE NAME DESCRIPTION MODEL COMMENTS PT1 PT2 POWER, DATA, AV POWER AND DATA SEE NOTE 1 , 2, 4 SEE NOTE 1, 3 S1R6PTWZXXX S1R6PTACEHXXX NOTES: 1. XXX COVER FINISH TO BE SELECTED BY OWNER OR ARCHITECT. 2. SUBPLATES TO BE DETERMINED. 3. 1-20A PREWIRED SUBPLATE ARE INCLUDED AS WELL AS SUBPLATES FOR DATA. 4. 1-20A PREWIRED SUBPLATE IS INCLUDED AS WELL AS SUBPLATES FOR DATA AND AV. PT31 FURNITURES1R6PTFFXXX FEED WITH POWER AND DATA SEE NOTE www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202 317.439.4355 (t) ...creating profitable environments.. . Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: PRIORITY PHYSICIANS 2/11/2021 10:05:21 AM E303.31 THIRD LEVEL POWER/SYSTEMS PLAN -TENANT 31 2019.00780 11.5.2020 CONSTRUCTION DOCUMENTS CARMEL MEDICAL ARTS PAVILION 12174 N. Meridian Street Carmel, Indiana 46032 1/8" = 1'-0" 1 THIRD LEVEL POWER/SYSTEMS PLAN - TENANT 31 PLAN NOTES 1 INSTALL RECEPTACLES AND DATA OUTLET IN AT 10" A.F.F. TO CENTER, ROUTE (1) 3/4" C FOR POWER AND (1) 1' 1/4" C FOR DATA FROM NEAREST WALL DOWN TO ABOVE 2ND FLOOR CEILING AND STUBBED UP INTO CASEWORK. COORDINATE CASEWORK INSTALL WITH CASEWORK SUPPLIER. 2 PROVIDE DUPLEX RECEPTACLE ABOVE ACCESSIBLE CEILING FOR OWNER PROVIDE EXAM LIGHT. 3 INSTALL DEVICE HORIZONTALLY AT 51.5" A.F.F. AND 19" FROM OUTER EDGE OF EXISTING BUILT-IN CABINET. 4 PROVIDE POKE THRU FLOOR BOX, (1) 1' 1/2" CONDUIT ABOVE 2ND FLOOR CEILING AND WALL MOUNTED MONITOR BACKBOX. REFER TO DETAIL ON SHEET EXXX. 5 STUB UP CONDUIT INTO CASEWORK, EXTEND (2) 3/4" ABOVE 2ND FLOOR CEILING AND UP NEAREST WALL. PROVIDE CONNECTION TO COOKTOP AND RECEPTACLE. 6 PROVIDE CONNECTION TO OWNER PROVIDED FURNITURE SYSTEM. COORDINATE FURNITURE WHIP WITH PROVIDER. 7 PROVIDE (1) 2" CONDUIT STUBBED UP NEAREST WALL FOR DATA. 8 INSTALL DEVICE(S) 1'-0" BELOW THE CEILING. 9 PROVIDE CIRCUIT IN J-BOX ABOVE CEILING FOR FUTURE LOGO SIGN LIGHT. 10 PROVIDE UNDER COUNTER RECEPTACLE FOR DISHWASHER. 11 PROVIDE SINGLE GANG BACKBOX AND (1) 3/4" C STUBBED UP ABOVE CEILING FOR REFRIGERATOR ALARM CIRCUIT. 12 INSTALL AT 72" A.F.F. FOR PERGOLA HEATER CONTROL PANEL. CONTRACTOR TO COORDINATE EXACT POWER REQUIREMENTS AND WIRING WITH MANUFACTURER. 13 ROUTE CIRCUIT THROUGH HEATER CONTROL PANEL. 14 PROVIDE CONNECTION TO KITCHEN HOOD. 15 PROVIDE UNDERCOUNTER SINGLE GANG BACKBOX WITH COVER FOR HARDWIRED CONNECTION TO TOUCHLESS FAUCET SYSTEM. CONNECT TO LOAD SIDE OF GFCI. COORDINATE INSTALLATION WITH CASEWORK AND FAUCET MANUFACTURER. 16 PROVIDE ROUGH-IN FOR KEYPAD. COORDINATE INSTALLATION AND POWER REQUIREMENTS WITH SYSTEM PROVIDER/INSTALLER. GENERAL NOTES A. REFER TO DRAWING E001 FOR ELECTRICAL SYMBOLS AND ADDITIONAL GENERAL NOTES. B. COORDINATE ALL WORK WITH THE OWNER AND THE OTHER TRADES ON THE PROJECT. C. REFER TO M AND P SERIES DRAWINGS FOR ADDITIONAL ELECTRICAL REQUIREMENTS. D. PROTECT ALL FINISHES, EQUIPMENT, AND DEVICES DURING THE WORK. E. REFER TO ARCHITECTURAL SCHEDULES, DETAILS, AND ELEVATIONS FOR ADDITIONAL INFORMATION ON DEVICE LOCATIONS PRIOR TO ROUGH-IN. COORDINATE LUMINAIRE INSTALLATION AND QUANTITIES WITH ARCHITECTURAL DRAWINGS. F. COORDINATE ALL WORK WITH THE OWNER'S SYSTEMS VENDORS FOR DEVICES AND WIRING FOR DATA, I.T. SERVICES, AND SECURITY SYSTEMS. G. ELECTRICAL SERVICES SHALL NOT ROUTE THROUGH ANY IDF OR MDF ROOM UNLESS DIRECTLY SERVING THAT \ ROOM. H. CONTRACTOR SHALL VERIFY CORD AND PLUG CONNECTED EQUIPMENT CORD CONFIGURATION AND PROVIDE MATCHING RECEPTACLE AS REQUIRED. I. ALL RECEPTACLES WITHIN SIX FEET OF A SINK SHALL BE GFCI TYPE. DEVICES MAY NOT BE IDENTIFIED AS GFCI ON PLANS, BUT SHALL BE PROVIDED ACCORDING TO THE REQUIREMENT. J. ALL SPECIAL TYPE RECEPTACLES SHALL BE NEMA 6-20R UNLESS NOTED OTHERWISE AND SHALL BE CIRCUITED WITH (2) #10 + (1) #10 NEUTRAL + (1) #10 GROUND. COORDINATE REQUIREMENTS WITH OWNER SUPPLIED EQUIPMENT PRIOR TO INSTALLATION. K. COORDINATE INSTALLATION OF LIGHT FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLAN, ARCHITECTURAL ELEVATIONS, HVAC EQUIPMENT, DIFFUSERS, DUCTWORK, PIPING, SUPPORTS, AND STRUCTURE PRIOR TO ROUGH-IN. L. ALL EXIT SIGNS, EMERGENCY BATTERY LIGHTING UNITS, AND LIGHT FIXTURES SHOWN WITH EMERGENCY BATTERY BACKUP OR INDICATED AS A NIGHT LIGHT ("NL") SHALL BE PROVIDED WITH AN UNSWITCHED "HOT" CIRCUIT CONDUCTOR. M. AT LOCATIONS WITH TWO OR MORE WALL SWITCHES, ALL SWITCHES SHALL BE INSTALLED GANGED IN A COMMON SWITCH BOX. N. AT LOCATIONS WHERE LIGHT SWITCHES AND ABOVE-COUNTER RECEPTACLES ARE TO BE MOUNTED ADJACENT TO EACH OTHER, THE DEVICES SHALL BE INSTALLED AT THE SAME HEIGHT. O. WHERE OCCUPANCY SENSORS ARE INDICATED ON PLANS, THE ENTIRE ROOM SHALL BE COVERED. SENSOR MANUFACTURER IS RESPONSIBLE FOR SENSOR LAYOUT. ADDITIONAL SENSORS REQUIRED DUE TO LACK OF COVERAGE SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. PROVIDE QUANTITIES AS REQUIRED. CEILING AND WALL MOUNTED SENSORS SHALL BE DUAL-TECHNOLOGY TYPE. SENSORS SHALL INCLUDED ALL POWER SUPPLIES AND RELAYS NECESSARY TO CONTROL LIGHT FIXTURES IN ROOM/AREA. SENSORS SHALL OPERATE IN "VACANCY" MODE - MANUAL ON/AUTO OFF. P. PROVIDE PULL STRING IN ALL EMPTY CONDUITS. Q. CONTRACTOR TO PROVIDE ROUGH-INS ONLY FOR DATA, I.T. SERVICES, AND SECURITY SYSTEMS. DATA, I.T. SERVICES, AND SECURITY SYSTEMS DEVICES AND WIRING TO BE PROVIDED BY THE OWNERS SYSTEMS VENDORS. PROVIDE ROUGH-INS WITH "RING AND STRING". R. COORDINATE DIMMING COMPATIBILITY WITH LED LUMINAIRE MANUFACTURER. S. INSTALL ALL SWITCHES AND DIMMERS AT +48" A.F.F. UNLESS NOTED OTHERWISE. REVISION SCHEDULE NO. DESCRIPTION DATE