HomeMy WebLinkAboutE802 - ELECTRICAL DETAILS(1) 1-1/2" CONDUIT FOR AV TO ABOVE ACCESSIBLE CEILING OR TO JOIST SPACE. TERMINATE CONDUIT WITH BUSHING. FINISHED FLOOR ACCESSIBLE CEILING WALL MOUNTED TELEVISION MONITOR FSR RECESSED DISPLAY PANEL WALL BOX NOTES: 1. FSR PWB-273 THREE INCH DEEP FLAT PANEL BACKBOX, COORIDINATE HEIGHT WITH OWNER PRIOR TO INSTALLATION. PROVIDE COMPLETE WITH MANUFACTURER'S BLANK COVERPLATE. COORDINATE INSTALLATION WITH REQUIRED BLOCKING. POWER ON THE BOTTOM AND DATA ON TOP. 2. INSTALL DUPLEX RECEPTACLE FLUSH IN BOTTOM OF FSR BACKBOX AT THIS LOCATION. 3. STUB CONDUIT ABOVE CEILING AND EXTEND TO NEAREST ACCESSIBLE CEILING. UTILIZE SWEEPING 90 DEGREE ELBOW AND INSTALL BUSHING. PROVIDE PULL STRING. 4. ROUTE 1-1/2" CONDUIT FROM FSR PWB-273 BACK BOX TO FLOOR BOX FOR TO TV. 5. FLOOR BOX / POKE THRU. 6. PROVIDE WOOD BLOCKING AT TV LOCATIONS. FSR PWB-272 5 2 1 (1) 3/4" CONDUIT FOR ELECTRICAL. (1) 1-1/4" CONDUIT FOR DATA TO ABOVE ACCESSIBLE CEILING OR TO JOIST SPACE. TERMINATE CONDUIT WITH BUSHING. NOTE 3 2 NOTE 6 NOTE 4 CONFIRM HEIGHT WITH ARCHITECTURAL ELEVATIONS AND DETAILS Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 2/11/2021 10:06:03 AM E802 ELECTRICAL DETAILS 2019.00780 11.5.2020 CONSTRUCTION DOCUMENTS CARMEL MEDICAL ARTS PAVILION 12174 N. Meridian Street Carmel, Indiana 46032 NO SCALE 1 TYPICAL CONFERENCE ROOM AUDIO/VIDEO OUTLET DETAIL REVISION SCHEDULE NO. DESCRIPTION DATE