HomeMy WebLinkAboutGN1.0 Project Data General Notes and LegendsGENERAL PROJECT NOTES:
A. UNLESS OTHERWISE INDICATED, GENERAL NOTES APPLY TO ALL WORK AND ALL DRAWINGS IN THIS SET AND SHALL EXTEND TO ANY CHANGES, EXTRAS OR ADDITIONS AS AGREED TO DURING THE COURSE OF THE
WORK.
B. THESE DRAWINGS AND COPIES THEREOF ARE LEGAL INSTRUMENTS OF SERVICE FOR USE OF THE OWNER/TENANT ONLY.
C. THIS PROJECT IS DESIGNED AND DOCUMENTED PER THE DESIGNER'S INTERPRETATION OF THE CODE REQUIREMENTS. VARIOUS GOVERNING AGENCIES SOMETIMES INTERPRET CODES, LAWS AND ORDINANCES DIFFERENTLY.
THESE AGENCIES HAVE
JURISDICTION TO REQUIRE CHANGES IN DESIGN AND CONSTRUCTION. ANY CHANGES OR MODIFICATIONS TO THE DESIGN MAY NECESSITATE PRICE ADJUSTMENTS.
D. ALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, RULES, REGULATIONS, AND STANDARDS, INCLUDING, BUT NOT LIMITED TO: THE INDIANA BUILDING CODE,
THE INDIANA CODES, THE INDIANA
FIRE CODES, THE AMERICANS WITH DISABILITIES ACT (ADA), UNIVERSAL BUILDING CODE, AND APPLICABLE TRADE STANDARDS. ALL APPLICABLE RULES AND REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED
EDITIONS.
E. THE ERRORS AND OMISSIONS DESIGN LIABILITY FOR THE PROJECT SHALL BE LIMITED TO THE DESIGN COST OF CORRECTING THE DEFICIENCY.
F. CONTRACTOR SHALL VISIT AND INSPECT THE PROJECT SITE PRIOR TO SUBMITTAL OF BID AND FAMILIARIZE THEMSELVES WITH THE CONDITIONS UNDER WHICH THE WORK WILL BE PERFORMED. THE CONTRACTOR
IS RESPONSIBLE FOR FIELD VERIFYING ALL
CONDITIONS AND DIMENSIONS PRIOR TO THE START OF WORK. REPORT ANY DISCREPANCIES TO THE DESIGNER IMMEDIATELY. FAILURE OF CONTRACTOR TO PERFORM IN THIS MANNER DOES NOT ALLOW FOR ADDITIONAL
COST TO THE OWNER. NO
SUBSEQUENT EXTRAS OR ADDITIONS WILL BE ALLOWED ON ANY CLAIM OF LACK OF KNOWLEDGE OF CONDITIONS OR CIRCUMSTANCES ABOUT WHICH THE CONTRACTOR COULD HAVE INFORMED THEMSELVES.
G. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL STATE AND LOCAL PERMITS REQUIRED FOR COMPLETION OF THIS PROJECT, WITH RESPECT TO THE
RESPONSIBILITY SCHEDULE LOCATED ON THE COVER PAGE OF THIS SET OF DOCUMENTS.
H. ALL WORK IS TO BE COORDINATED BY THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT, FINISH, SYSTEM OPERATION, AND FULL COMPLETION OF THE WORK, INCLUDING SERVICE REQUIREMENTS OF THE OWNER/TENANT'S
F.F.E.
I. CONTRACTOR SHALL MAKE KNOWN ANY LIMITATIONS, EXCLUSIONS, OR MODIFICATIONS TO THE PROJECT DURING THE PRICING PHASE OF THE PROJECT. UNLESS NOTED ALL WORK SHOWN ON THE DRAWINGS WILL
BE PRESUMED TO BE INCLUDED.
J. ALL CONTRACTORS INVOLVED IN THIS WORK SHALL CARRY PROPERTY DAMAGE AND PUBLIC LIABILITY INSURANCE AS REQUIRED BY OWNER & GOVERNMENTAL AGENCIES HAVING JURISDICTION AND COMPLY WITH STATUTORY
REQUIREMENTS FOR
DISABILITY AND WORKMEN'S COMPENSATION. THEY WILL COMPLY WITH ALL RULES AND REGULATIONS DICTATED BY THE OWNER AND THE CONDITIONS OF THE JOB. INSURANCE SHALL PROTECT THE OWNER, THE TENANT,
ARCHITECT/DESIGNER AND OTHER
GROUP(S) TO BE NAMED FROM LIABILITY TO THE CONTRACTOR'S NEGLIGENCE.
K. THE AIA STANDARD DOCUMENT A201 SHALL BE MADE PART OF THE GENERAL CONDITIONS.
L. ALL DIMENSIONS ARE SHOWN ON THE DRAWINGS. DIMENSIONS SHALL GOVERN. DETAILS SHALL GOVERN OVER PLANS AND ELEVATIONS; LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS. ANY DIMENSIONS
NOT SHOWN OR DEEMED
QUESTIONABLE ARE TO BE VERIFIED WITH THE DESIGNER. DO NOT SCALE DIMENSIONS ON THE DRAWINGS. ALL DIMENSIONS ARE TO THE FACE OF GYPSUM BOARD, MASONRY/CONCRETE WALLS, OR CENTERLINE OF COLUMNS
UNLESS NOTED OTHERWISE.
M. THERE SHALL BE NO SUBSTITUTION OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED.
N. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISTRIBUTION OF DRAWINGS TO ALL TRADES UNDER THEIR EMPLOY.
O. THE GENERAL CONTRACTOR SHALL SUPPLY, PRIOR TO THE COMMENCEMENT OF WORK, A LIST OF ALL SUBCONTRACTORS TO ARCHITECT. THE NAME OF THE PRINCIPAL CONTACT, THE ADDRESS AND PHONE NUMBER
OF EACH SUBCONTRACTOR SHALL
BE INCLUDED ON THE LIST.
P. THE GENERAL CONTRACTOR SHALL FURNISH SAMPLES TO ARCHITECT/INTERIOR DESIGNER OF ALL MATERIALS, TOGETHER WITH FINISHES, INTENDED FOR USE IN THE WORK BEFORE THE COMMENCEMENT/ORDER OF
THE SPECIFIED WORK.
Q. ANY INFORMATION REQUIRED BY CONTRACTORS THAT IS NOT SHOWN ON THE DRAWINGS OR CONTAINED IN OTHER CONTRACT DOCUMENTS SHALL BE REQUESTED BY THE GENERAL CONTRACTOR FROM ARCHITECT/INTERIOR
DESIGNER.
R. A REPRESENTATIVE OF THE GENERAL CONTRACTOR AUTHORIZED TO DISCUSS THE WORK AND RECEIVE INFORMATION FROM ARCHITECT SHALL BE AVAILABLE AT ALL TIMES THAT WORK IS IN PROGRESS.
S. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND CUT SHEETS TO ARCHITECT/INTERIOR DESIGNER FOR APPROVAL ON ALL ITEMS INCLUDING BUT NOT LIMITED TO MILLWORK, LIGHTING, FINISH MATERIALS, PLUMBING
FIXTURES AND ACCESSORIES PRIOR
TO ORDER. SHOP DRAWINGS SHALL SHOW ALL DIMENSIONS AND CONDITIONS.
T. CONTRACTOR IS TO SIGN EACH SHOP DRAWING SUBMITTAL CERTIFYING THAT THE SUBMITTAL HAS BEEN REVIEWED, APPROVED, AND THAT THE CONTRACTOR COORDINATION HAS BEEN PERFORMED.
U.
V. FINISHED DOOR OPENINGS IN NEW PARTITIONS SHALL BE SET 6" FROM ADJACENT PERPENDICULAR PARTITIONS, UNLESS NOTED OTHERWISE.
W. PROVIDE BLOCKING IN WALLS TO ACCOMMODATE ALL CASEWORK AND WALL MOUNTED EQUIPMENT.
X. ALL FINISH CARPENTRY IS TO BE COMPLETED IN STRICT ACCORDANCE WITH A.W.I. STANDARDS, PREMIUM GRADE.
Y. ALL FIRE EXTINGUISHER CABINET LOCATIONS ARE TO BE COORDINATED BY THE FACILITY WITH THE LOCAL FIRE OFFICIALS PRIOR TO INSTALLATION. COORDINATE FINAL FIRE EXTINGUISHER LOCATIONS WITH
PHANOMEN/design PRIOR TO ROUGH-IN.
STYLE TO BE SEMI-RECESSED, HINGED DOOR WITH GLASS. SUBMIT CUT-SHEET TO PHANOMEN/design FOR APPROVAL.
Z. CONTRACTOR(S) SHALL PROVIDE ALL NECESSARY LABOR, MATERIALS, AND EQUIPMENT FOR THE WORK IN THESE DOCUMENTS, UNLESS CLEARLY NOTED "NOT IN CONTRACT" (N.I.C.), AS APPLIES TO A 'WARM WHITE
BOX' SCOPE. EXISTING WORK ADJACENT TO
THE AREA OF NEW WORK SHALL BE PROTECTED BY ALL SUITABLE MEANS NECESSARY TO PREVENT OR MINIMIZE DAMAGE. GREAT CARE SHALL BE EXERCISED TO ASSURE THAT THE BUILDING SHALL BE PROTECTED FROM
DAMAGE THAT COULD OCCUR BECAUSE OF THIS WORK. ANY
DAMAGES CAUSED BY THIS WORK OR ACCIDENTS SHALL BE REPAIRED, REPLACED OR PATCHED TO THE SATISFACTION OF ARCHITECT AND THE OWNER. CONTRACTORS SHALL BEAR FINANCIAL RESPONSIBILITY FOR SUCH
DAMAGE AND ANY WORK
UNDERTAKEN TO CORRECT IT.
AA. THE CONTRACTORS SHALL EXERCISE GREAT CARE IN PROTECTION FROM DAMAGE ALL MATERIALS EXISTING ON THE JOB AND SHALL MAINTAIN PROTECTION FOR ALL TRAFFIC AREAS OF THE BUILDING TO BE USED
DURING THE EXECUTION OF WORK
RELATING TO THIS CONTRACT WITH THE UNDERSTANDING THAT THE CONTRACTOR'S WILL RECTIFY ANY DAMAGE ATTRIBUTABLE TO THEIR OPERATION.
AB. CONTRACTORS SHALL KEEP WORK AREAS AND ADJACENT PUBLIC CORRIDORS AND FACILITIES FREE OF DEBRIS. MATERIALS STORED ON SITE ARE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE STORED
IN A LOCATION APPROVED BY THE
OWNER.
AC. ALL PLUMBING ITEMS AND/OR EQUIPMENT ITEMS ARE TO BE COORDINATED AND VERIFIED WITH INTERIOR ELEVATIONS PRIOR TO ROUGH-IN. ANY DISCREPANCIES SHALL BE COORDINATED WITH PHANOMEN/design.
AD. GYPSUM BOARD SURFACES SHALL BE ISOLATED WITH CONTROL JOINTS AS PER MANUFACTURERS REQUIREMENTS AND INDUSTRY STANDARDS.
AE. ALL GYPSUM BOARD SURFACES ARE TO BE FINISHED SMOOTH. GYPSUM ASSOCIATION GA-214-96 LEVEL 4 FINISH, WITH THE FOLLOWING ADDITION; ANY READILY VISIBLE IMPERFECTIONS IN GYPSUM BOARD SURFACE
SHALL BE COATED WITH JOINT
COMPOUND AND/OR SKIM-COATED AS REQUIRED.
AF. SCRIBE GYPSUM BOARD OF WALL AND PARTITIONS TO IRREGULARITIES OF DECK ABOVE. SEAL TIGHTLY AROUND ANY PARTITIONS.
AG. EACH TRADE SHALL BE HELD RESPONSIBLE FOR KNOWLEDGE OF THE GENERAL NOTES INCLUDED THROUGHOUT THE CONTRACT DOCUMENTS AND THE APPLICABLE BUILDING CODES.
AH. THE HVAC, PLUMBING AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. SHOULD THERE BE ANY DISCREPANCY BETWEEN THE VARIOUS DRAWINGS, IT SHALL BE BROUGHT TO THE
DESIGNER AND ENGINEERS
ATTENTION FOR CLARIFICATION.
AI. CONTRACTOR MUST VERIFY AND COORDINATE ALL OPERATIONAL REQUIREMENTS AND CLEARANCE DIMENSIONS OF PROJECT COMPONENTS; INCLUDING CONTRACTOR SUPPLIED AND OWNER SUPPLIED ITEMS.
AJ. CONTRACTOR SHALL ITEMIZE ALL COSTS AND SCOPE OF WORK REGARDING ANY CHANGE ORDER. THIS INFORMATION MUST BE PRESENTED TO THE OWNER FOR APPROVAL PRIOR TO ANY WORK BEING EXECUTED.
AK. ALL LIGHT FIXTURES THAT COME INTO CONTACT WITH BUILDING INSULATION MUST BE IC RATED. ALL LIGHT FIXTURES SHALL MEET ALL APPLICABLE CODES FROM NATIONAL ELECTRIC CODE (NEC) TO THE INTERNATIONAL
ENERGY CODE (IEC).
CONTRACTOR IS TO VERIFY CODE COMPLIANCE OF ALL LIGHT FIXTURES.
AL. METAL STUD CONTRACTOR IS RESPONSIBLE FOR GAUGING AND RELATED ENGINEERING OF METAL STUD FRAMED WALLS UNLESS NOTED OTHERWISE ON ENGINEERING DRAWINGS.
AM. THESE PLANS ARE INTENDED FOR "GUIDELINE" BID AND CONSTRUCTION PURPOSES ONLY AND DO NOT INCLUDE DETAILS AND METHODS OF CONSTRUCTION FOR ALL AREAS. SUBSTITUTIONS OF MATERIALS AND METHODS
MAY BE PROVIDED, UPON
APPROVAL OF OWNER AND DESIGNER/ARCHITECT.
AN. THE PROJECT TEAM, AS LISTED, CANNOT GUARANTEE AGAINST HUMAN ERROR, OMISSIONS OR INACCURACIES CONTAINED WITHIN THESE DOCUMENTS. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COMMUNICATING
ALL QUESTIONS AND
CONCERNS TO THE PROJECT TEAM TO SEEK CLARIFICATION AND/OR SOLUTIONS PRIOR TO THE COMMENCEMENT OF THE SPECIFIED WORK.
AO. ALL CONTRACTORS AND SUPPLIERS SHALL BEFORE COMMENCING WORK, REVIEW ALL PLANS AND SPECIFICATIONS AND VERIFY ALL DIMENSIONS AND DETAILS FOR THEIR WORK AND REPORT ANY DISCREPANCIES
OR VARIATIONS TO THE DESIGNER
PRIOR TO FINAL BID, ORDER/FABRICATION, CONSTRUCTION AND INSTALLATION OF ANY MATERIAL. THE GENERAL CONTRACTOR SHALL EXAMINE ALL ADJOINING WORK OR AREAS UPON WHICH THE PERFORMANCE OF THEIR
WORK IS IN ANY WAY
DEPENDENT.
AP. ALL MATERIALS SHALL BE NEW, UNUSED, AND OF THE HIGHEST QUALITY IN EVERY RESPECT UNLESS OTHERWISE NOTED. MANUFACTURED MATERIALS AND EQUIPMENT SHALL BE INSTALLED AS PER THE MANUFACTURER'S
RECOMMENDATIONS AND
INSTRUCTIONS UNLESS OTHERWISE NOTED.
AQ.ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE, AND IN PROPER ALIGNMENT.
AR. SEE COVER SHEET GENERAL NOTES FOR CODE COMPLIANCE.
AS. THE GENERAL CONTRACTOR SHALL KEEP SUFFICIENT WORKMEN ON THE JOB SITE AT ALL TIMES TO PERFORM THE WORK IN THE MOST EXPEDITIOUS MANNER CONSISTENT WITH GOOD WORKMANSHIP, GOOD BUSINESS
PRACTICE AND THE BEST INTERESTS
OF THE OWNER.
AT. EACH TRADE WILL BE EXPECTED TO PROCEED IN A FASHION THAT WILL NOT DELAY OR DETAIN THE TRADES FOLLOWING THEM.
AU. THE CONTRACTORS SHALL NOT PROCEED WITH ANY ADDITIONAL WORK OR CHANGES FOR WHICH THEY EXPECT ADDITIONAL COMPENSATION BEYOND THE CONTRACT AMOUNT WITHOUT WRITTEN AUTHORIZATION FROM
OWNER. FAILURE TO OBTAIN
SUCH AUTHORIZATION SHALL INVALIDATE ANY CLAIM FOR EXTRA COMPENSATION.
AV. ALL WORK AND MATERIALS SHALL BE GUARANTEED AGAINST DEFECTS IN DESIGN, WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE (1) YEAR.
AW. THE CONTRACTORS SHALL AT ALL TIMES KEEP THE PREMISES FREE OF THE ACCUMULATION OF WASTE MATERIALS OR RUBBISH CAUSED BY THEIR OPERATIONS. THE CONTRACTORS SHALL CONFINE THEIR OPERATIONS
FOR REMOVAL TO SUCH METHODS
AS MAY BE AGREEABLE WITH THE OWNER. THE PROJECT SHALL BE LEFT CLEAN AND CLEAR, TO THE SATISFACTION OF THE OWNER, AND THE DISPOSITION OF ALL SALVAGED MATERIALS IS TO BE CLEARED WITH THE
OWNER PRIOR TO REMOVAL. THE PREMISES
SHALL BE SWEPT CLEAN DAILY OF RELATED CONSTRUCTION DEBRIS.
AX. UPON SUBSTANTIAL COMPLETION OF THE WORK, THE GENERAL CONTRACTOR SHALL NOTIFY ARCHITECT TO SCHEDULE A "PUNCH LIST" WALK THROUGH IT IS INTENDED THAT THE GENERAL CONTRACTOR PROVIDE
A COMPLETE JOB AND ANY OMISSIONS
IN THESE NOTES OR IN THE OUTLINE OF WORK SHALL NOT BE CONSTRUED AS RELIEVING THE GENERAL CONTRACTOR OF SUCH RESPONSIBILITIES IMPLIED BY THE SCOPE OF WORK EXCEPT FOR ITEMS SPECIFICALLY
NOTED.
AY. SHOULD ANY PORTION OF THE CONTRACT DOCUMENTS PROVE TO BE, FOR WHATEVER REASON, UNENFORCEABLE, SUCH UNENFORCEABILITY SHALL NOT EXTEND TO THE REMAINDER OF THE CONTRACT NOR SHALL IT
VOID ANY OTHER PROVISIONS OF
THE CONTRACT.
AZ. THE GENERAL CONTRACTOR SHALL HAVE A COPY OF THE LATEST SET OF CONTRACT DOCUMENTS ON THE JOB SITE AT ALL TIMES FOR REVIEW BY ARCHITECT. ALL DRAWINGS AND CONSTRUCTION NOTES ARE COMPLIMENTARY
AND WHAT IS CALLED
FOR BY ONE SHALL BE BINDING AS IF CALLED FOR BY ALL.
BA. COMPLETE RECORD DOCUMENTS TO BE MAINTAINED SEPARATELY FROM THE FIELD SET. THE RECORD SET SHALL HAVE ALL FIELD CHANGES DOCUMENTED AND WILL BE PROVIDED TO ARCHITECT AT THE COMPLETION
OF PROJECT. PROVIDE A COPY OF
THE RECORD DOCUMENTS TO THE LANDLORD.
BB. THE WORK INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY FOR, AND REASONABLY INCIDENTAL TO, THE COMPLETION IN PLACE OF ALL WORK ILLUSTRATED AND
DESCRIBED IN THE DRAWINGS AND
SPECIFICATIONS, AS THEY APPLY TO A 'WARM WHITE BOX' SCOPE. ALL SUCH WORK IS TO BE DONE BY THE CONTRACTORS UNLESS OTHERWISE NOTED IN THE RESPONSIBILITY SCHEDULE ON THE COVER SHEET OF
THIS SET.
BC. THE GENERAL CONTRACTOR SHALL SUBMIT CONFIRMATIONS WITH DELIVERY DATES OF ORDERS FOR MATERIALS AND EQUIPMENT ON ANY LONG LEAD-TIME ITEMS AT THE COMMENCEMENT
BD. BREAK ROOM APPLIANCES INCLUDING BUT NOT LIMITED TO RANGE HOOD, COOKTOP/STOVE, REFRIGERATOR, DISHWASHER, AND MICROWAVE SHALL BE PROCURED BY THE TENANT/OWNER (PRIORITY), UNLESS OTHERWISE
NOTED. ALL APPLIANCE
BE. SIGNAGE REQUIRES SEPARATE REVIEW, PERMITS, AND FEES. TENANT/OWNER SHALL BE RESPONSIBLE FOR OBTAINING SUCH PERMITS, UNLESS OTHERWISE DISCUSSED. (TENANT) OWNER/OWNER'S VENDOR SHALL
SUBMIT BUILDING SIGNAGAE TO CITY FOR APPROVAL PRIOR TO
INSTALLATION.
BF. FIRE SPRINKLER AND FIRE ALARM SYSTEMS SHALL BE PROVIDED PER NFPA NO.13. APPROVALS TO BE OBTAINED FROM LOCAL FIRE MARSHAL. CONTRACTOR TO SUBMIT ALL REQUIRED DRAWINGS AND INFORMATION
TO FIRE MARSHAL AND AUTHORITY
FOR APPROVAL PRIOR TO COMMENCEMENT OF ANY RELATED WORK. OBTAIN APPROVAL OF COMPLETED SYSTEMS PRIOR TO FINAL ACCEPTANCE.
ALL CONTRACTORS INVOLVED IN THIS PROJECT SHALL REVIEW ALL DRAWINGS INCLUDED IN THIS DRAWING SET AND SHALL COORDINATE THEIR WORK WITH OTHER TRADES ON THIS PROJECT.
CUTSHEETS ARE TO BE FORWARDED TO THE MEP DESIGN/BUILD ENGINEERS FOR THEIR COORDINATION.
N
S
W E NORTH ARROW
WORK POINT, CONTROL POINT,
OR DATUM POINT
A
1 GRID LINES
X
A1.6
SECTION
SHEET WHERE DRAWN
2
A200
DETAIL NUMBER
SHEET WHERE DRAWN
INTERIOR ELEVATION
SHEET WHERE DRAWN
ROOM
207 ROOM NAME
ROOM NUMBER
7 PLAN KEYNOTE
207 DOOR
SEE DOOR SCHEDULE
WALLTYPE
SEE WALLTYPES
WALL FINISH
SEE FINISH LEGEND
CENTER LINE
ABBREVIATIONS GRAPHIC SYMBOLS
SYMBOL DESCRIPTION
A/C AIR CONDITIONING
AC ACOUSTICAL
ADA AMERICANS WITH DISABILITIES ACT
ADJ ADJACENT
AFF ABOVE FINISHED FLOOR
ALUM ALUMINUM
ARCH ARCHITECTURAL
AVG AVERAGE
BLDG BUILDING
BM BEAM / BENCHMARK
B.O. BOTTOM OF
BSMT BASEMENT
BUR BUILT UP ROOF
BW BOTTOM OF WALL
CAB CABINET
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLOS CLOSET
CLR CLEAR
CMT CERAMIC MOSAIC TILE
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONF CONFERENCE
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CPT CARPET
CT CERAMIC TILE
CTR CENTER
CWT CERAMIC WALL TILE
DBL DOUBLE
DEMO DEMOLITION
DET / DTL DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM (S) DIMENSION(S)
DIV DIVISION / DIVIDED
DN DOWN
DPM DAMP PROOF MEMBRANE
DS DOWNSPOUT
DWG DRAWING
DWR DRAWER
E EAST
EA EACH
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATOR / ELEVATION
EO EDGE OF
EPDM ETHYLENE PROPYLENE DIENETERPOLYMER MEMBRANE
EPS EXTRUDED POLYSTYRENE
EQ EQUAL
EQUIP EQUIPMENT
EX / EXIST EXISTING
EXP EXPANSION / EXPOSED
EXT EXTERIOR
EWC ELECTRIC WATER COOLER
FA FIRE ALARM
FD FLOOR DRAIN
FDN FOUNDATION
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FLR FLOOR
FOF FACE OF FINISH
FOS FACE OF STUD
FP FIRE PROTECTION
FT FOOT / FEET
FTG FOOTING
FTR FIRE TREATED
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GCMU GLAZED CONCRETE MASONRY UNIT
GFRG GLASS FIBER REINFORCED GYPSUM
GL GLASS / GLAZING
GWB GYPSUM WALL BOARD
HC HOLLOW CORE
HDWE HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HR HOUR
HT HEIGHT
HVAC HEATING / VENTILATING / AIR CONDITIONING
HWH HOT WATER HEATER
ID INSIDE DIAMETER
IG INSULATED GLASS
INCL INCLUDE(D, ING)
INSUL INSULATION
INT INTERIOR
JAN JANITOR
JT JOINT
KIT KITCHEN
LAM LAMINATE
LAV LAVATORY
LH LEFT HAND
LIN LINOLEUM
LOC LIMIT OF CONTRACT
LP LOW POINT
LTG LIGHTING
MAX MAXIMUM
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MFG MANUFACTURING
MFR MANUFACTURER
MGR MANAGER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
N NORTH
NAT NATURAL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NR NOT RATED
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O/ OVER
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OPH OPPISITE HAND
OPNG OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIIN
OSB ORIENTED STRAND BOARD
PC PIECE / PERSONAL COMPUTER
PERF PERFORATED
PL PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
PR PAIR
PREFAB PREFABRICATED
PRES PRESIDENT
PRTD / PTRD PRESSURE TREATED
PT PAINT
PTD PAINTED
QTY QUANTITY
QTILE QUARRY TILE
R RADIUS / RISER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
REFRIG REFRIGERATOR
REINF REINFORCE(D, ING)
REQD REQUIRED
REV REVISION
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
RR RESTROOM
RWC RAIN WATER CONDUCTOR
S SOUTH
SCHED SCHEDULE
SDT STATIC DISSIPATIVE TILE
SECT SECTION
SECY SECRETARY
SHT SHEET
SIC SOUND ISOLATION CEILING
SIM SIMILAR
SPEC SPECIFIED / SPECIFICATION
SQ SQUARE
SQ FT SQUARE FEET
SSM SOLID SURFACE MATERIAL
SS STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STN STONE
STOR STORAGE
STR STAIR
STRUCT STRUCTURAL
SY SQUARE YARD
T TREAD
T&G TONGUE AND GROOVE
T/O THROUGHOUT
TELE TELEPHONE
TEMP TEMPORARY
TERR TERRAZZO
THRES THRESHOLD
T.O. TOP OF
TRANSP TRANSPARENT
TRCT TERRACOTTA TILE
TW TOP OF WALL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VP VICE PRESIDENT
VWC VINYL WALLCOVERING
W WEST
W/ WITH
WC WATERCLOSET
WD WOOD
WDW WINDOW
W/O WITHOUT
WP WATERPROOF
WT WEIGHT
WWF WELDED WIRE FABRIC
CPT-1 X HWD-1
WX WINDOW TAG
MAX.
2' - 3"
MIN.
6' - 8"
4" MAX.
MAX.
2' - 3"
MIN.
6' - 8"
MIN.
1' - 6"
MIN.
5' - 0"
FRONT APPROACH PULL SIDE
MIN.
1' - 0" *
MIN.
4' - 0"
FRONT APPROACH PUSH SIDE
* IF BOTH CLOSER AND LATCH ARE PROVIDED
MIN.
3' - 0"
MIN.
5' - 0"
HINGE APPROACH PULL SIDE
MIN.
3' - 6"
MIN.
4' - 6"
HINGE APPROACH PULL SIDE
MIN.
3' - 6" **
HINGE APPROACH PUSH SIDE
* IF BOTH CLOSER AND LATCH ARE PROVIDED
** 48" MIN. IF BOTH CLOSER AND LATCH ARE PROVIDED
1' - 0" *
MIN.
1' - 10"
MIN.
4' - 0" *
LATCH APPROACH PULL SIDE
* 54" IF CLOSER IS PROVIDED
MIN.
2' - 0"
MIN.
3' - 6" *
LATCH APPROACH PUSH SIDE
* 48" IF CLOSER IS PROVIDED
MIN.
2' - 0"
CLEAR
5' - 0" MIN.
CLEAR
4' - 8" MIN.
MIN.
2' - 6"
MIN.
4' - 0"
PROTRUDING OBJECTS REDUCED VERTICAL CLEARANCE WATER CLOSET & LAV. CLEARANCE CLEAR WIDTH ACCESSIBLE ROUTE
MAX.
2' - 0"
MIN.
4' - 0"
MAX.
2' - 0"
MIN.
2' - 8"
MIN.
3' - 0"
NOTE:
INFORMATION SHOWN IS TAKEN FROM THE AMERICAN NATIONAL STANDARD INSTITUTE
(ANSI) AND IS FOR REFERENCE ONLY AS DESCRIBED IN: ANSI ICC A117.1-2009
APPROACH PLANS ASSUME DOOR HAS CLOSER
CHANGES IN LEVEL
MAX. MAX.
MAX.
MAX.
1/4"
1/2"
1/2" 1/4"
2
1
2
1
3' - 0" 3' - 0"
3' - 0"
4' - 0"
TRANSFER SHOWER CLEARANCE
SEAT WALL
BACK WALL
BUILDING ACCESSIBILITY LEGEND:
1' - 6"
2'-0" REQ. IN SOME
CONDITIONS,
VERIFY
W/ARCHITECT
1' - 0"
WALL
DOOR
ADJACENT WALL WHERE
APPLICABLE
DOOR FRAME
WALL
PULL SIDE
PUSH SIDE
NOTE: SHOULD DIMENSIONS ON DRAWINGS
PROVIDE SMALLER CLEARANCES THAN
SHOWN HERE CONTACT ARCHITECT FOR
CLARIFICATION PRIOR TO PROCEEDING.
DOOR CLEARANCE MINIMUMS
SITE ACCESSIBILITY NOTES:
1.
2.
3.
4.
5.
6.
PUBLIC ENTRANCES: AT LEAST 60% SHALL BE ACCESSIBLE.
AN ACCESSIBLE ROUTE OF NOT LESS THAN 3 FT. WIDE MUST BE
PROVIDED TO ALL PORTIONS OF THE BUILDING AND BETWEEN THE
BUILDING AND THE PUBLIC WAY. ACCESSIBLE ROUTES SHALL HAVE
A MAXIMUM SLOPE OF 1:20 AND A MAXIMUM CROSS SLOPE OF
1:50
ACCESSIBLE ROUTE SHALL BE WITHOUT STEPS OR CHANGES IN
LEVEL GREATER THAN 1/2" WITHOUT AN APPROVED RAMP
ACCESSIBLE RAMPS THAT ARE REQUIRED BY ANSI A 117.1 SHALL
NOT HAVE A SLOPE THAT EXCEEDS 1FT. IN 12 FEET. RAMPS AND
GROUND SURFACES SHALL BE OF A SLIP RESISTANT SURFACE
THRESHOLDS MUST BE 1/2" OR LESS IN HEIGHT
ALL ALARMS TO MEET ACCESSIBLITY REQUIREMENTS
FUTURE SUBMITTALS
ALL BELOW FALL UNDER GENERAL CONTRACTOR SCOPE
FIRE SPRINKLER AND FIRE ALARM SYSTEM
FIRE SPRINKLER AND FIRE ALARM SYSTEM WILL BE SUBMITTED
AS A DEFERRED SUBMITTAL BY THE SYSTEM INSTALLER.
SIGNS
SIGNAGE DESIGN AND CONSTRUCTION DOCUMENTS WILL
BE SUBMITTED UNDER A SEPERATE PERMIT BY THE SYSTEM
INSTALLER.
TOILET
PARTITION
PEDESTAL MOUNTED SIGN FOR CAR
PEDESTAL MOUNTED SIGN FOR VAN
NOTE:
MOUNT FLUSH
VALVE / HANDLE
ON WIDE SIDE
24"x 36"
MIRROR
MIRROR -
FULL WIDTH
OF COUNTER
WALL
MOUNTED
SIGN
B/F WATER CLOSET STALLS 2ND B/F WATER CLOSET STALL
IF (6) OR MORE WATER CLOSET STALLS ARE PROVIDED.
STANDARD WATER CLOSET STALLS B/F URINAL STANDARD URINAL
B/F & STAND. SINK w/ COUNTER B/F & STANDARD LAVATORY B/F SIGNAGE
URINAL SCREEN
3' - 0"
2' - 4"
1' - 5"
3' - 0" 6"
CLEAR
3' - 6" 1' - 6"
2' - 4" 8"
1' - 5"
2' - 4" *
3' - 0"
3' - 4" 1' - 6"
3' - 4"
1' - 0" 3' - 6"
5' - 0" CLEAR 4' - 0"
TOILET
PARTITION
TOILET
PARTITION
3' - 0" 5' - 0" 4' - 0"
1' - 0" 3' - 6"
3' - 4"
3' - 4" 1' - 6"
3' - 0"
2' - 4" *
1' - 5"
3' - 0"
2' - 4"
1' - 6" 1' - 6"
MAX.
2' - 6"
MIN.
2' - 6"
2' - 6" 5' - 0" 3' - 0"
2' - 6"
MAX.
2' - 6"
MIN.
2' - 6" 3' - 0"
1' - 3"
2' - 4"
2' - 4"
6' - 2"
TO LIP OF SINK
2' - 10" MAX.
MIN.
2' - 6"
1' - 3" 1' - 3"
3' - 2"
MIRROR
3' - 0"
1' - 10"
BOWL
3" INSIDE
9"
2' - 3"
8"
2' - 5"
TO LIP OF SINK
2' - 10" MAX.
6" 1' - 4" 4' - 0" CLEAR
6' - 2"
2' - 10" MAX.
MIN.
2' - 6"
1' - 3" 1' - 3"
3' - 2"
MIRROR
3' - 0"
6" 1' - 0" 4' - 0" CLEAR
9"
8"
2' - 3"
TO LIP OF SINK
2' - 10" MAX.
2' - 5"
3' - 8"
MAX.
1' - 10"
MIN.
2' - 6"
MIN.
2' - 8"
1' - 4" 1' - 4"
MAX.
1' - 5"
1' - 3" 1' - 3"
MAX.
1' - 0" 4' - 0"
1' - 9"
6' - 8" 1' - 6"
6' - 8" 5" 1' - 6"
1' - 0" 1' - 0"
1' - 0"
5' - 0" 1' - 6"
6" MIN.
(12" MIN.-CHILD)
9" MIN (ADULT)
(12" MIN.-CHILD)
9" MIN (ADULT)
(12" MIN.-CHILD)
9" MIN (ADULT)
7" - 9" 7" - 9"
*DESIGN SHOWN FOR
SINGLE ROLL DISPENSER
7" - 9"
*DESIGN SHOWN FOR
SINGLE ROLL DISPENSER
Certified By:
Scale:
Date:
Checked By:
Drawn By:
Job Number:
Drawing Number:
Drawing Name:
CARMEL, IN 46032
01.22.2021
www.phanomen.com
934 Fort Wayne Ave. - Indianapolis, IN 46202
317.439.4355 (t)
PRIORITY PHYSICIANS ...creating profitable environments...
Revisions:
12174 N. MERIDIAN
SUITE 300
AS NOTED
BSL/BSH
LOE
PROJECT DATA, GENERAL
NOTES, AND LEGENDS
GN1.0
PERMIT SET 01.22.2021
WT-X
X
A1.6