HomeMy WebLinkAboutLS1.1 Life SafteyDW
MF
MF
N
S
W
E
Certified By:
Scale:
Date:
Checked By:
Drawn By:
Job Number:
Drawing Number:
Drawing Name:
CARMEL, IN 46032
01.22.2021
www.phanomen.com
934 Fort Wayne Ave. - Indianapolis, IN 46202
317.439.4355 (t)
PRIORITY PHYSICIANS ...creating profitable environments...
Revisions:
12174 N. MERIDIAN
SUITE 300
1/8" = 1'-0"
BSL/BAR
LOE
LIFE SAFETY
LS1.1
PERMIT SET 01.22.2021
1/8"=1'-0"
1 THIRD FLOOR LIFE SAFETY PLAN
1
73'-0
1
2
"
106'-91
2"
100'
21'-3"
COMMON PATH
OF TRAVEL
140'-3"
TRAVEL DISTANCE
73'-0
1
4
"
67'-7"
PROJECT SCOPE:
Project includes the initial tenant build-out of the third floor of a primary care
medical office. The existing shell of the building was separately submitted and is
outside the scope of these documents.
BUILDING DESCRIPTION:
TYPE 'B' OCCUPANCY
CONSTRUCTION TYPE CLASSIFICATION:
TYPE II-B - SPRINKLERED
FIRE RESISTANCE RATING REQUIREMENTS:
STRUCTURAL FRAME: NONFLAMMABLE (EXISTING)
EXTERIOR BEARING WALLS: NONFLAMMABLE (EXISTING)
NONBEARING WALLS & PARTITIONS: ANY MATERIAL
TENANT SEPARATION: (EXISTING)
SHAFT ENCLOSURES: (EXISTING)
STAIR ENCLOSURES: (EXISTING)
ACTUAL AREA: 14,042 SF
OFFICE 'B' OCCUPANCY: 12,045.67 SF/ 100 = 120.46 OCC.
CONFERENCE 'A' OCCUPANCY: 396.8 SF/ 15 = 26.46 OCC.
STORAGE OCCUPANCY: 618.45 SF/ 500 = 1.24 OCC.
PATIO OCCUPANCY: 981.34 SF/ 15 = 65.42 OCC.
TOTAL MAX. OCCUPANCY: 213.58 OR 214 OCCUPANTS
EXIT ANALYSIS:
14,832 SF (TYPE 'B' OCCUPANCY) WITH A TOTAL OCCUPANT LOAD OF 214, PER IBC
TABLE 1014.1, SHALL HAVE A MINIMUM OF TWO (2) EXITS. TWO (2) EXITS HAVE BEEN
PROVIDED.
MAXIMUM COMMON PATH OF TRAVEL DISTANCE: 100 FT
MAXIMUM EXIT ACCESS TRAVEL DISTANCE: 300 FT
EGRESS ANALYSIS:
214 OCCUPANTS X .15 (2014 INDIANA BUILDING CODE TABLE 1005.1) = 32.1"
PER IBC 1020.2, 44" MINIMUM REQUIRED WIDTH, 72" PROVIDED.
RESTROOM ANALYSIS:
TOTAL OCCUPANTS = 214
1 FIXTURE PER 25 OCCUPANTS REQUIRED FOR FIRST 50 OCCUPANTS AND 1 FIXTURE
REQUIRED FOR EACH REMAINING 50 OCCUPANTS THEREAFTER
TOTAL OF 6 FIXTURES REQUIRED, 12 FIXTURES PROVIDED
1 LAVATORY PER 40 OCCUPANTS REQUIRED FOR FIRST 80 OCCUPANTS AND 1
LAVATORY REQUIRED FOR EACH REMAINING 80 OCCUPANTS THEREAFTER
TOTAL OF 4 LAVATORIES REQUIRED, 12 LAVATORIES PROVIDED
136'-0"
TRAVEL DISTANCE
SHELL BUILDING - FIRE RESISTIVE WALL SEPARATION REQUIREMENTS
SHELL BUILDING CONSTRUCTION TYPE: 2B
FIRE RESISTIVE REQUIREMENTS FOR BUILDING ELEMENTS: TABLE 601
BEARING WALLS
INTERIOR ZERO (0) HOUR
EXTERIOR ZERO (0) HOUR
NONBEARING WALLS
EXTERIOR ZERO (0) HOUR
INTERIOR ZERO (0) HOUR
STRUCTURAL FRAME ZERO (0) HOUR
SHAFT ENCLOSURE ONE (1) HOUR
FLOOR CONSTRUCTION ZERO (0) HOUR
ROOF CONSTRUCTION ZERO (0) HOUR
STAIRWAY CONSTRUCTION ONE (1) HOUR
EXIT DIRECTION ARROW
ROOM NAME
COMMON PATH OF TRAVEL / EXIT ACCESS TRAVEL DISTANCE
LEGEND:
EXIT
ROOM NUMBER
EMERGENCY LIGHT
WALL MOUNTED EXIT SIGN
CEILING MOUNTED EXIT SIGN
WALL MOUNTED DIRECTIONAL EXIT SIGN
FIRE EXTINGUISHER (ON HOOK) UNDER CABINET OR ON WALL
## DISBURSEMENT OF OCCUPANTS TO EXITS
F.E.
EXIT SIGN WITH EMERGENCY LIGHT
O.L.S.
OCCUPANT LOAD SIGN
ADA COMPLAINT TACTILE EXIT SIGN
EXIT
SHELL BUILDING DATA:
CODE SUMMARY:
EXIT EXIT
EXIT
EXIT
ROOM NAME
000
FILED SEPARATELY UNDER STATE PROJECT NUMBER 415893 - RELEASED 5/27/2020
33 33
107
107
17
17
1-HOUR FIRE BARRIER
(PREVIOUSLY APPROVED UNDER SHELL PACKAGE)
UL FIRE RESISTANCE RATING LABEL
(PREVIOUSLY APPROVED UNDER SHELL PACKAGE)
45 MIN
F.E.
F.E.
45 MIN
45 MIN
AQUARIUM
MAINT.
302
BREAK
ROOM
318
LARGE CONF
ROOM
316
MEDICAL
STORAGE
334
BLOOD
DRAW
303
M. PRIDDY
OFFICE 4
338
J. RIZZUTO
OFFICE 5
339
EXAM 1
306A
EX 1
PATIENT RR
306B
EXAM 2
307A
EX 2
PATIENT RR
307B
GENERAL
STORAGE
332
OFFICE 1
335
OFFICE 3
337
PHARMACY
& SAMPLES
304
OFFICE 7
330
MOLE MAPPING
(PHOTO FINDER)
329
STORAGE
305
JANITOR
328
EXAM 3
308A
EX 3
PATIENT RR
308B
LAB
322
PROCEDURE
ROOM
317
OFFICE 8
327
UNISEX
RESTROOM
319
EXAM 10
PEDIATRIC
315A
EX PED
PATIENT RR
315B
EX 4
PATIENT RR
309B
OFFICE 9
326
OFFICE 10
325
EXAM 5
310A
PROCEDURE &
BLOOD DRAW
323
SHOWER
ROOM
320
EXAM 9
314A
EX 9
PATIENT RR
314B
EXAM 8
313A
EX 8
PATIENT RR
313B
EXAM 4
309A
EX 5
PATIENT RR
310B
EX 6
PATIENT RR
311B
EX 7
PATIENT RR
312B
EXAM 6
311A
EXAM 7
312A
OFFICE 2
336
RECEPTION
300
WAITING LOUNGE
301
SOILED
LINENS
321
STORAGE
324
BACK HALL
333
OPEN
OFFICE
340
HALLWAY
341
HALLWAY
342 HALLWAY
343
HALLWAY
344
HALLWAY
345
HALLWAY
346
IT
EXISTING
STAIR 2
NIC
EXISTING
STAIR 1
NIC
EXIST. EM LIGHT/EXIST
SIGN COMBO FIXTURE
EXIST. EM LIGHT/EXIST
SIGN COMBO FIXTURE
EXIST. ELEC
ROOM
NIC