Loading...
HomeMy WebLinkAboutLS1.1 Life SafteyDW MF MF N S W E Certified By: Scale: Date: Checked By: Drawn By: Job Number: Drawing Number: Drawing Name: CARMEL, IN 46032 01.22.2021 www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202 317.439.4355 (t) PRIORITY PHYSICIANS ...creating profitable environments... Revisions: 12174 N. MERIDIAN SUITE 300 1/8" = 1'-0" BSL/BAR LOE LIFE SAFETY LS1.1 PERMIT SET 01.22.2021 1/8"=1'-0" 1 THIRD FLOOR LIFE SAFETY PLAN 1 73'-0 1 2 " 106'-91 2" 100' 21'-3" COMMON PATH OF TRAVEL 140'-3" TRAVEL DISTANCE 73'-0 1 4 " 67'-7" PROJECT SCOPE: Project includes the initial tenant build-out of the third floor of a primary care medical office. The existing shell of the building was separately submitted and is outside the scope of these documents. BUILDING DESCRIPTION: TYPE 'B' OCCUPANCY CONSTRUCTION TYPE CLASSIFICATION: TYPE II-B - SPRINKLERED FIRE RESISTANCE RATING REQUIREMENTS: STRUCTURAL FRAME: NONFLAMMABLE (EXISTING) EXTERIOR BEARING WALLS: NONFLAMMABLE (EXISTING) NONBEARING WALLS & PARTITIONS: ANY MATERIAL TENANT SEPARATION: (EXISTING) SHAFT ENCLOSURES: (EXISTING) STAIR ENCLOSURES: (EXISTING) ACTUAL AREA: 14,042 SF OFFICE 'B' OCCUPANCY: 12,045.67 SF/ 100 = 120.46 OCC. CONFERENCE 'A' OCCUPANCY: 396.8 SF/ 15 = 26.46 OCC. STORAGE OCCUPANCY: 618.45 SF/ 500 = 1.24 OCC. PATIO OCCUPANCY: 981.34 SF/ 15 = 65.42 OCC. TOTAL MAX. OCCUPANCY: 213.58 OR 214 OCCUPANTS EXIT ANALYSIS: 14,832 SF (TYPE 'B' OCCUPANCY) WITH A TOTAL OCCUPANT LOAD OF 214, PER IBC TABLE 1014.1, SHALL HAVE A MINIMUM OF TWO (2) EXITS. TWO (2) EXITS HAVE BEEN PROVIDED. MAXIMUM COMMON PATH OF TRAVEL DISTANCE: 100 FT MAXIMUM EXIT ACCESS TRAVEL DISTANCE: 300 FT EGRESS ANALYSIS: 214 OCCUPANTS X .15 (2014 INDIANA BUILDING CODE TABLE 1005.1) = 32.1" PER IBC 1020.2, 44" MINIMUM REQUIRED WIDTH, 72" PROVIDED. RESTROOM ANALYSIS: TOTAL OCCUPANTS = 214 1 FIXTURE PER 25 OCCUPANTS REQUIRED FOR FIRST 50 OCCUPANTS AND 1 FIXTURE REQUIRED FOR EACH REMAINING 50 OCCUPANTS THEREAFTER TOTAL OF 6 FIXTURES REQUIRED, 12 FIXTURES PROVIDED 1 LAVATORY PER 40 OCCUPANTS REQUIRED FOR FIRST 80 OCCUPANTS AND 1 LAVATORY REQUIRED FOR EACH REMAINING 80 OCCUPANTS THEREAFTER TOTAL OF 4 LAVATORIES REQUIRED, 12 LAVATORIES PROVIDED 136'-0" TRAVEL DISTANCE SHELL BUILDING - FIRE RESISTIVE WALL SEPARATION REQUIREMENTS SHELL BUILDING CONSTRUCTION TYPE: 2B FIRE RESISTIVE REQUIREMENTS FOR BUILDING ELEMENTS: TABLE 601 BEARING WALLS INTERIOR ZERO (0) HOUR EXTERIOR ZERO (0) HOUR NONBEARING WALLS EXTERIOR ZERO (0) HOUR INTERIOR ZERO (0) HOUR STRUCTURAL FRAME ZERO (0) HOUR SHAFT ENCLOSURE ONE (1) HOUR FLOOR CONSTRUCTION ZERO (0) HOUR ROOF CONSTRUCTION ZERO (0) HOUR STAIRWAY CONSTRUCTION ONE (1) HOUR EXIT DIRECTION ARROW ROOM NAME COMMON PATH OF TRAVEL / EXIT ACCESS TRAVEL DISTANCE LEGEND: EXIT ROOM NUMBER EMERGENCY LIGHT WALL MOUNTED EXIT SIGN CEILING MOUNTED EXIT SIGN WALL MOUNTED DIRECTIONAL EXIT SIGN FIRE EXTINGUISHER (ON HOOK) UNDER CABINET OR ON WALL ## DISBURSEMENT OF OCCUPANTS TO EXITS F.E. EXIT SIGN WITH EMERGENCY LIGHT O.L.S. OCCUPANT LOAD SIGN ADA COMPLAINT TACTILE EXIT SIGN EXIT SHELL BUILDING DATA: CODE SUMMARY: EXIT EXIT EXIT EXIT ROOM NAME 000 FILED SEPARATELY UNDER STATE PROJECT NUMBER 415893 - RELEASED 5/27/2020 33 33 107 107 17 17 1-HOUR FIRE BARRIER (PREVIOUSLY APPROVED UNDER SHELL PACKAGE) UL FIRE RESISTANCE RATING LABEL (PREVIOUSLY APPROVED UNDER SHELL PACKAGE) 45 MIN F.E. F.E. 45 MIN 45 MIN AQUARIUM MAINT. 302 BREAK ROOM 318 LARGE CONF ROOM 316 MEDICAL STORAGE 334 BLOOD DRAW 303 M. PRIDDY OFFICE 4 338 J. RIZZUTO OFFICE 5 339 EXAM 1 306A EX 1 PATIENT RR 306B EXAM 2 307A EX 2 PATIENT RR 307B GENERAL STORAGE 332 OFFICE 1 335 OFFICE 3 337 PHARMACY & SAMPLES 304 OFFICE 7 330 MOLE MAPPING (PHOTO FINDER) 329 STORAGE 305 JANITOR 328 EXAM 3 308A EX 3 PATIENT RR 308B LAB 322 PROCEDURE ROOM 317 OFFICE 8 327 UNISEX RESTROOM 319 EXAM 10 PEDIATRIC 315A EX PED PATIENT RR 315B EX 4 PATIENT RR 309B OFFICE 9 326 OFFICE 10 325 EXAM 5 310A PROCEDURE & BLOOD DRAW 323 SHOWER ROOM 320 EXAM 9 314A EX 9 PATIENT RR 314B EXAM 8 313A EX 8 PATIENT RR 313B EXAM 4 309A EX 5 PATIENT RR 310B EX 6 PATIENT RR 311B EX 7 PATIENT RR 312B EXAM 6 311A EXAM 7 312A OFFICE 2 336 RECEPTION 300 WAITING LOUNGE 301 SOILED LINENS 321 STORAGE 324 BACK HALL 333 OPEN OFFICE 340 HALLWAY 341 HALLWAY 342 HALLWAY 343 HALLWAY 344 HALLWAY 345 HALLWAY 346 IT EXISTING STAIR 2 NIC EXISTING STAIR 1 NIC EXIST. EM LIGHT/EXIST SIGN COMBO FIXTURE EXIST. EM LIGHT/EXIST SIGN COMBO FIXTURE EXIST. ELEC ROOM NIC